Description
1. Commercial Introduction
We make available to operating theatres, general and digestive surgery departments, gynaecology units, urology and purchasing centres the absorbable monofilament suture of poliglecaprone 25 (PGCL / caprolactone) from the PREMISUT Prime range, factory reference P322DS2620 (SKU Cahnos AMP322DS2620). This presentation combines a ⅜ circle needle with a 26 mm reverse cutting triangular point (DS26 Prime profile), USP 2/0 gauge and a 75 cm colourless grooved thread: a highly versatile format for soft tissue approximation and general ligatures, with exceptional handling, secure knot, minimal tissue reaction and full batch traceability. Each unit is delivered sterile, ready for immediate use, in a box of 12 units in individual sachets.
2. Technical explanation of the material and procedure
Poliglecaprone 25 (PGCL) is a synthetic copolymer of poly(glycolic acid 75 % – co-caprolactone 25 %) in an uncoated monofilament structure. Its single-strand design reduces drag (saw effect) during passage through tissue, minimises capillarity and hinders bacterial adherence compared with braided multifilament sutures, while maintaining high tensile strength and reliable knot tying during the critical phases of healing.
Absorption occurs by controlled hydrolysis —a predictable mechanism independent of enzymatic activity— over a period of 90 to 120 days (average absorption), with an approximate retention of original strength of 60 % at 7 days and 30 % at 14 days after implantation. It is not recommended when prolonged tissue support is required (e.g., fascia).
The DS26 needle of 26 mm, with ⅜ circle curvature and a grooved reverse cutting triangular point, concentrates the cutting edge on the outer face of the curvature: it penetrates firm and poorly distensible tissues (skin, aponeurosis, dense subcutaneous tissue) with minimal resistance and better aesthetic results, preventing the cut from widening in the puncture bed. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference P322DS2620
| Parameter | Specification |
| Brand / Quality | PREMISUT Prime (premium range, grooved needle) |
| Factory reference | P322DS2620 |
| Reference Cahnos (SKU) | AMP322DS2620 |
| Thread material | Poliglecaprone 25 (PGCL) – copolymer 75 % glycolic acid / 25 % ε-caprolactone |
| Thread structure | Synthetic absorbable monofilament, grooved surface |
| Coating | Uncoated |
| Gauge / size | USP 2/0 (metric EP 3), conforming to USP and European Pharmacopoeia |
| Approximate thread diameter | 0.30 – 0.339 mm |
| Thread length | 75 cm (1 strand / 1 needle per unit) |
| Thread colour | Colourless (grooved) |
| Needle shape | 3/8 circle (⅜ circular), body and point |
| Tip type | Triangular reverse cutting (Reverse Cutting), grooved |
| Needle size | DS26 Prime (26 mm) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 90 – 120 days (average absorption) |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Soft tissue approximation and general ligatures |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Conforms to USP and European Pharmacopoeia (EP) gauges |
| Storage | Below 30 °C, away from moisture and direct sunlight |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
| 1 week | 60% of initial tensile strength |
| 2 weeks | 30% of initial tensile strength |
| Complete absorption | 90–120 days, by hydrolysis |
3.3. Gauge equivalence according to USP / EP Pharmacopoeia (absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 (this product) | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
4. Equivalences and Cross-References
Reference P322DS2620 corresponds to the official nomenclature of the PREMISUT Prime range (DS26 profile: ⅜ circle needle with 26 mm reverse cutting triangular point, USP 2/0 gauge, 75 cm colourless grooved thread, single-strand configuration) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Poliglecaprone 25 is one of the most standardised synthetic absorbable monofilaments with medium absorption on the international market. The clinical reference in the category is the MONOCRYL® line from Ethicon (Johnson & Johnson MedTech), along with homologous families such as MONOSYN® from B. Braun (based on gluconate, with different degradation kinetics) and the PGCL lines from DemeTECH (DemeCAPRONE), SMI (Caprofyl®), Healthium (Monoglyde®), Assut Medical, Dolphin Sutures (Petcryl Mono), WEGO and CP Medical.
The codes of the MONOCRYL® and MONOCRYL® Plus programmes with ⅜ circle reverse cutting triangular needle (plastic surgery series with needles from 11 to 24 mm, e.g. Y489H / MPY493H / MPY500H / MPY683H / W3203–W3208 and the variants MCP489H / MCP493H / MCP496H / MCP500H / MCP683H) have been verified in the official Ethicon technical data sheet. However, all of them mount needles of 11–24 mm —outside the ±1 mm tolerance with respect to the DS26 needle of 26 mm of this reference— and thread lengths of 45 or 70 cm, so they are not interchangeable 1:1 and cannot be declared direct equivalents: they are comparable by category, and the exact gauge (colourless monofilament, USP 2/0) must also be validated in the manufacturer’s data sheet.
There is no manufacturer-validated equivalence table that cross-references this specific reference (PGCL monofilament, DS26 26 mm reverse cutting needle, USP 2/0 gauge, 75 cm colourless thread, ref. P322DS2620) with references from other houses in the exact configuration; consult the technical department before use in tendering. The homologous families cited must be reviewed property by property (material, gauge, curvature, point family, length and number of strands, colour, coating and current CE/MDR regulatory classification) before any substitution. This needle geometry (DS26, USP 2/0, single 75 cm strand) is only fully safely interchangeable within the PREMISUT system itself. The factory reference of this article does not appear in public regulatory databases (GUDID/EUDAMED) and must be confirmed with the supplier before use in specifications. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
Tissue to suture: the USP 2/0 gauge (metric EP 3) with a 26 mm needle is suitable for approximating medium-thickness tissues: subcutaneous tissue, fascia, muscle wall, peritoneum and ligatures where strength is required during the first 2–3 weeks of healing. The reverse cutting point penetrates dense tissues without tearing the puncture bed and improves the aesthetic result.
Quality and presentation: this reference is single-strand (1×75 cm) in the Prime range with a grooved needle. If the procedure requires continuous or multi-point sutures without re-threading, the double-thread variant AMP322DS2620.2 (2×75 cm) is available, which reduces the opening of sachets per intervention.
Alternative gauges and needles in the same PGCL range: same DS26 profile in USP 3/0 (AMP322DS2630 in Prime or AM322DS2630 in standard), USP 4/0 (AMP322DS2640), DS30 profile in USP 3/0 (AMP322DS3030) or USP 2/0 (AM322DS3020) and DS40 profile in USP 0 (AM322DS4010).
Absorption profile: if the procedure requires longer wound support, consider polydioxanone PDO (180–210 days); if a shorter absorption profile is needed, consider PGA (60–90 days) or polyglactin 910 (56–72 days).
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep the reference P322DS2620 and the batch number for traceability in the operating theatre, and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.