We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Monofilament Suture PGCL Poliglecaprone 25 (Caprolactone) PREMISUT Prime | ½ Circle Cylindrical Taper Point Needle Taperpoint HR26 of 26 mm | USP Gauge 2/0 (Metric 3) | Violet Thread 90 cm | Box of 12 units | Ref. P313HR2620

Original price was: 55,30 €.Current price is: 36,95 €.

Synthetic absorbable monofilament suture of Poliglecaprone 25 (PGCL / Caprolactone) in Prime quality, factory reference P313HR2620 (SKU AMP313HR2620). Mounted on an atraumatic ½ circle needle, cylindrical body and taper point Taperpoint of 26 mm (HR26), USP gauge 2/0 and violet thread of 90 cm with high visibility in the surgical field. Predictable absorption by hydrolysis in 90–120 days, with tensile strength retention of 60% at one week and 30% at two weeks, minimal tissue reaction and excellent knot security. Indicated for approximation of soft tissues and ligatures in general surgery, gynaecology, urology and obstetrics. Sterilised by ethylene oxide, single-use and non-resterilisable. B2B presentation in a box of 12 sterile units; minimum order 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM313HR2620

Description

1. Commercial Introduction

At Cahnos we make available to operating theatres, general surgery departments, gynaecology, urology and obstetrics units and purchasing centres the absorbable monofilament poliglecaprone 25 (PGCL, caprolactone) suture from the Prime range, factory reference P313HR2620 (SKU AMP313HR2620). This presentation combines a ½ circle needle with cylindrical body and 26 mm Taperpoint conical point (HR26), USP 2/0 gauge and 90 cm violet thread.

It is a medium-absorption thread (90–120 days), with exceptional handling and high knot security, designed for the professional who needs reliable wound healing support during the first weeks with a very competitive quality-performance ratio for hospital procurement. Synthetic absorbable medical device, sterile and single-use, presented in a box of 12 units.

2. Technical Explanation

Poliglecaprone 25 is a synthetic absorbable copolymer (glycolide and ε-caprolactone) with a monofilament structure that degrades by hydrolysis, i.e. by cleavage of the polymer chains in contact with organic fluids, over a predictable period of 90 to 120 days and independent of the patient’s enzymatic activity. As a monofilament, the strand has a smooth surface that reduces friction when passing through tissue, minimises the sawing effect and hinders bacterial adherence, while maintaining high tensile strength and reliable knot security during the critical phases of wound healing.

The ½ circle needle with cylindrical body and Taperpoint conical point passes through soft tissues separating the fibres without a cutting effect, which makes it especially atraumatic in delicate structures, subcutaneous tissue and soft tissue approximation. USP 2/0 gauge (metric 3) provides an excellent balance between strength and manageability, and the violet colour ensures optimal visibility of the thread on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. Technical data sheet for reference AMP313HR2620

Parameter Specification
Reference (SKU Cahnos) AMP313HR2620
Factory reference P313HR2620 (PREMISUT POLIGLECAPRONE 25 CAPROLACTONE PGCL PRIME)
Range / Quality Prime (premium range)
Material Polyglecaprone 25 (PGCL / caprolactone), synthetic absorbable monofilament
Thread structure Monofilament
Gauge USP 2/0 (metric 3), in accordance with USP/EP Pharmacopoeia
Thread colour Violet (high visibility)
Thread length 90 cm (1 thread · 1 needle per unit)
Needle shape ½ circle (half circumference)
Needle body and point Cylindrical body, Taperpoint conical tip, atraumatic
Needle size HR26 – 26 mm
Absorption mechanism Hydrolysis
Absorption period 90–120 days
Sterilisation Ethylene oxide (EO), sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Soft tissue approximation and general ligatures
Presentation Box of 12 sterile units · minimum order 30 boxes

3.2. Tensile strength retention profile

Period after implantation Tensile strength retention
1 week 60 % of initial strength
2 weeks 30 % of initial strength
Complete absorption 90–120 days, by hydrolysis

Complete absorption by hydrolysis between 90 and 120 days, with minimal tissue reaction, excellent initial tensile strength, optimal knot security and a fully predictable absorption rate. Price per box of 12 units.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia (absorbable suture)

USP size Metric measurement (EP) Approximate diameter
2/0 (this product) 3 0.30 – 0.339 mm
3/0 2 0.20 – 0.249 mm
0 3.5 0.35 – 0.399 mm
1 4 0.40 – 0.499 mm

4. Equivalences and Cross-References

Poliglecaprone 25 is the polymer used in Ethicon’s MONOCRYL® line (Johnson & Johnson MedTech), a clinical reference in the category of synthetic absorbable monofilament with medium absorption, together with homologous families from Assut Medical, DemeTECH (DemeCAPRONE), SMI and other manufacturers. For this specific configuration (PGCL monofilament, USP 2/0 gauge, ½ circle 26 mm conical point needle, 90 cm violet thread), the following correspondence has been verified against the manufacturer’s official catalogue (EPC Ethicon) and authorised distribution, with the caveat that the commercial assembly of each manufacturer presents differences in needle code and presentation, so they are not 1:1 interchangeable:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) MONOCRYL® (poliglecaprone 25) violet monofilament, USP 2/0, 90 cm, CT-2 26 mm needle, ½ circle, taperpoint conical point Y326H Comparable by category (not interchangeable 1:1) Confirmed in EPC Ethicon catalogue (code Y326H: MONOCRYL VIO 90CM M3) and authorised distribution: they match in material (poliglecaprone 25), USP 2/0 gauge, violet colour, monofilament structure, ½ circle geometry, 26 mm needle size, conical point family and 90 cm thread length. They differ in needle code (CT-2 taperpoint vs. HR26 Taperpoint) and commercial presentation (Ethicon box of 36 units vs. 12 units). Validate in the technical data sheet/IFU before substituting in a tender.

There is no equivalence table validated by the manufacturer for an exact 1:1 cross-reference with Taperpoint conical point (HR26 Prime), USP 2/0 gauge, violet thread and 90 cm; consult the technical department before using in a tender. The factory reference PREMISUT for this article does not appear in public regulatory databases (GUDID/EUDAMED) and must be confirmed with the supplier before use in tender specifications. As homologous market families to verify in their official data sheet before substitution, the following are cited: MONOCRYL® / MONOCRYL® Plus from Ethicon (poliglecaprone 25), Monosyn from B. Braun (glyconate), Caprosyn and Biosyn from Medtronic (glycomer) and medium-absorption monofilaments from other suppliers (DemeTECH, Assut, SMI), checking one by one: exact material, USP gauge, ½ circle curvature, 26 mm needle size, conical point family, thread length, colour, strength retention and current CE/MDR classification. The cited trademarks belong to their respective manufacturers and are mentioned solely as comparative reference.

5. Selection tips and variants of interest

USP 2/0 gauge (metric 3) with a 26 mm needle is very versatile: it is indicated for skin, subcutaneous tissue, mucosa, fascia, muscle, soft tissue approximation and ligation of fine-to-medium calibre vessels, with reliable wound healing support during the first 2–3 weeks. The ½ circle 26 mm needle with Taperpoint conical point is the most atraumatic option for delicate tissues; if greater penetration is required in firm or slightly fibrous tissues, consider the trocar point versions (Tapercut / Ultra Plus) of the same family.

Reference Recommended variant
AMP313HR2620 PGCL Prime, HR 26 mm needle, Taperpoint conical point, USP 2/0, violet, 90 cm (analysed product)
AMP313HRP2620 PGCL Prime, HRP 26 mm needle, Taperpoint Ultra Plus conical point, USP 2/0, violet, 90 cm (fluted precision point)
AMP318HRP2620 PGCL Prime, HRP 26 mm needle, Ultra Plus conical point, USP 2/0, violet, 70 cm (shorter thread)
AMP312HR2620 PGCL Prime, HR 26 mm needle, conical point, USP 2/0, violet, 75 cm (short thread)
AMP312HR2620.2 PGCL Prime, HR 26 mm taper-point needle, USP 2/0, violet, double thread 2×75 cm (double armed)
AMP318HR2620VB PGCL Prime, HR 26 mm VisiBlack taper-point needle, USP 2/0, violet, 70 cm (maximum needle contrast)

All references are supplied in boxes of 12 units. If the procedure requires longer wound support, consider polydioxanone PDO (180–210 days); if a shorter absorption profile is needed, consider PGA (60–90 days) or polyglactin 910 (56–72 days). As this is sterile single-use material, check the integrity of the pouch and the expiry date before each procedure and store the suture in a cool, dry place below 30 °C, protected from direct sunlight. For special B2B volume conditions, hospital supply contracts or validation of equivalence with other commercial brands, contact our technical-commercial team.

Additional information

Material

Poliglecaprone 25 (PGCL / Caprolactone), synthetic absorbable monofilament

USP size

2/0 (metric 3)

Thread length

90 cm (1 thread · 1 needle per unit)

Needle type

Cylindrical body, atraumatic Taperpoint conical point

Needle size

HR26 – 26 mm

Absorption mechanism

Hydrolysis, 90–120 days

Strength retention

60 % at 1 week / 30 % at 2 weeks

Sterilisation

Ethylene oxide (EO), single-use, not for re-sterilisation

Indications

Soft tissue approximation and general ligatures

Manufacturer reference

P313HR2620

Presentation

Box of 12 sterile units

Minimum order

30 boxes

Medida de aguja

HR 26

Usp

2/0

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Estructura hilo

Monofilament

Reviews

There are no reviews yet.

Be the first to review “Absorbable Monofilament Suture PGCL Poliglecaprone 25 (Caprolactone) PREMISUT Prime | ½ Circle Cylindrical Taper Point Needle Taperpoint HR26 of 26 mm | USP Gauge 2/0 (Metric 3) | Violet Thread 90 cm | Box of 12 units | Ref. P313HR2620”

Your email address will not be published. Required fields are marked *