Description
1. Commercial Introduction
At Cahnos we offer you the multifilament absorbable suture PREMISUT RAPID rapid polyglycolic acid (PGAR) in Prime quality, reference SKU AMP222GS6030, a professional solution designed for B2B supply to operating theatres, purchasing centres and general surgery services. This presentation combines a straight 60 mm needle (GS60) with a triangular conventional cutting tip, colourless thread of 75 cm in USP 3/0 gauge and a short and totally predictable absorption profile: sufficient tissue support during the critical healing phase, without the need for material removal. Reliable mechanical behaviour, minimal tissue response and excellent knot tying, in a box presentation of 12 units and special supply conditions for volume contracts.
2. Technical explanation of the material and procedure
Polyglycolic acid (PGA) in its rapid absorption variant (PGAR) is a synthetic absorbable polymer presented in a braided multifilament structure coated with polycaprolactone and calcium stearate. This coating provides a smooth, non-fluted surface that slides gently through tissue, reduces the saw effect and protects the thread during knotting, achieving a firm and secure knot relationship.
Its absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the thread retains approximately 50 % of the initial tensile strength at 5 days and loses practically all its resistance by 14 days, being completely reabsorbed between 40 and 45 days. This support window makes it ideal for rapidly healing tissues that require temporary approximation.
The straight GS60 needle (60 mm), with a triangular conventional cutting point, penetrates firm tissues with a clean and controlled cut of the path, being especially useful for manual suturing on directly accessible surfaces: approximation stitches, superficial continuous sutures and ligatures. The colourless colour provides maximum discretion on the surgical field. The product is supplied sterile by gamma radiation, is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference AMP222GS6030
| SKU Cahnos | AMP222GS6030 |
| Tariff reference (PREMISUT) | P222GS6030 |
| Quality | Prime (PREMISUT RAPID range) |
| Material | 100% polyglycolic acid (PGA), rapid absorption variant (PGAR) |
| Thread structure | Braided multifilament, non-grooved surface |
| Coating | Polycaprolactone and calcium stearate |
| USP gauge / size | USP 3/0 (metric 2) |
| Thread length | 75 cm (single strand) |
| Needle shape | Straight |
| Tip type | Triangular – conventional cutting (conventional cutting) |
| Needle size | 60 mm (GS60 model) |
| Thread colour | Colourless |
| Absorption mechanism | Hydrolysis |
| Total absorption | 40 – 45 days |
| Sterilisation | Gamma radiation; sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
3.2. Tensile strength retention profile after implantation
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis (predictable and uniform rate) |
3.3. Gauge equivalence (according to USP Pharmacopoeia)
| USP size | Metric size | Approximate diameter |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
4. Equivalences and Cross-References
The multifilament rapid absorption polyglycolic acid falls into the category of braided synthetic absorbable sutures with rapid loss of strength. The following reference from another manufacturer has been checked against official sources for the GS60 configuration (straight 60 mm needle, USP 3/0, 75 cm):
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL RAPIDE™ (polyglactin 910, undyed) | W9943 – USP 3/0, 75 cm, straight 60 mm needle | Comparable by category (not interchangeable 1:1) | It matches in USP 3/0 gauge, thread length of 75 cm, straight needle geometry of 60 mm, colourless colour and rapid absorption profile (50 % at 5 days, 0 % at 14 days). They differ in the polymer (polyglactin 910 vs polyglycolic acid PGAR) and the point type (reverse cutting in VICRYL RAPIDE vs the conventional cutting of this reference). |
The homologous families on the market with a comparable absorption profile are also the Safil Quick and Novosyn Quick ranges from B. Braun (braided PGA with rapid loss of strength) and the Surgicryl® Rapid series from SMI. It has not been possible to verify in public sources a specific code from these houses that reproduces the combination GS60 · USP 3/0 · 75 cm with a conventional cutting point.
There is no equivalence table validated by the manufacturer that cross-references this specific configuration (straight conventional cutting GS60 needle of 60 mm, USP 3/0 gauge, colourless thread of 75 cm) with references from other commercial houses; consult the technical department of Cahnos before using this information in tenders or for direct replacement of references. Any code of VICRYL RAPIDE™ or other rapid absorption brand must be checked against its technical data sheet and IFU before proposing substitution, given that needle nomenclatures, point type and armament vary by manufacturer. The brands cited belong to their respective manufacturers and are mentioned only as a functional comparison by category.
5. Selection tips and variants of interest
To choose the correct suture, verify three parameters: USP gauge (this model, USP 3/0, is very versatile and is intended for skin, subcutaneous tissue, mucosa and tissues with moderate tension in short-duration procedures), needle geometry (straight conventional cutting GS60 for manual suturing of direct access with path control; the circular variants 3/8 or 1/2 are reserved for reduced fields) and absorption profile (RAPID for tissue support of 7–10 days; the medium absorption versions are reserved for tissues that require longer mechanical support).
Variants of interest within the Cahnos catalogue: AM222GS6030 (PGAR RAPID, GS60, USP 3/0, colourless, 75 cm, standard quality) as a direct equivalent within the same manufacturer; AMP2L22GS6030 and AM2L22GS6030 (polyglactin 910 RAPID, GS60, USP 3/0, colourless, 75 cm) as material alternatives with the same absorption profile; AMP2L22GS6030.2 (same configuration in double thread 2×75 cm) to optimise performance in the operating theatre; and AMP222GS4820 (PGAR Prime, GS48, USP 2/0, colourless, 75 cm) for a shorter needle and larger gauge. If the protocol requires longer support, compare with medium absorption polyglactin 910 (PGLA, 56–72 days) or with standard polyglycolic acid (PGA, 60–90 days) available in straight GS60 needle format.
As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply agreements or enquiries about equivalents from other manufacturers, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.