We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGAR RAPID 3/8 Circle Reverse Cutting Triangular DS24, USP 3/0, Undyed 45 cm — Box of 12 units

Original price was: 44,90 €.Current price is: 34,80 €.

Absorbable multifilament suture of rapid absorption polyglactic acid (PGAR), Prime model, with ⅜ circular needle with reverse cutting triangular point of 24 mm, USP 3/0 thread, undyed and 45 cm length. Absorption by hydrolysis in 40-45 days, with retention of 50% of tensile strength at 5 days. Sterilised by gamma radiation. Ideal for tissue approximation, ligatures and general surgery. Price per box of 12 units (minimum order 30 boxes); reference AMP221DS2430.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP221DS2430

Description

1. Presentation

The absorbable suture PGAR RÁPIDO Prime is the recommended choice for surgeons who need a thread with rapid and predictable absorption and excellent knot handling. Its low molecular weight polyglactic acid formulation accelerates the loss of tensile strength, making it especially suitable for rapidly healing tissues and general surgery procedures, tissue approximation and ligatures. It is supplied in a box of 12 units, ready for use in the operating theatre.

2. What it is and how it works

This suture is a braided and coated multifilament of polyglactic acid (PGAR, rapid absorption polymer), which is reabsorbed by hydrolysis. Unlike medium absorption PGA sutures, the RAPID version loses tensile strength much earlier: it retains approximately 50% of its strength at 5 days and practically all at 14 days, with absorption completing between 40 and 45 days. This kinetic profile avoids keeping foreign material in the wound bed longer than necessary and minimises tissue reaction. The ⅜ circle needle with reverse cutting triangular point passes through firm tissues with a clean passage and lower risk of tearing, being ideal for skin and subcutaneous tissue, as well as for ligatures and closures in general surgery.

3. Technical Specifications

Composition 100% polyglactic acid (PGAR / rapid PGA), braided multifilament
Coating Polycaprolactone and calcium stearate
Absorption By hydrolysis, between 40 and 45 days
Strength resorption 50% at 5 days · 0% at 14 days
Gauge USP 3/0 (metric 2, Ph. Eur.)
Thread length 45 cm
Colour Colourless
Needle ⅜ circle, body and reverse cutting triangular point, 24 mm (DS 24)
Sterilisation Gamma radiation
Presentation Box of 12 units
SKU / Ref. AMP221DS2430 (PREMISUT RAPID Prime)

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer for this reference; consult the technical department before using it in tenders or direct substitution. At category level, the functional profile of this suture (absorbable multifilament with rapid absorption, based on low molecular weight polyglactic acid/polyglactin, braided and coated, absorption ≈40-45 days) is comparable to that of homologous families from other manufacturers: VICRYL RAPIDE (low molecular weight polyglactin 910), Safil Quick (B. Braun, low molecular weight PGA) and Novosyn Quick (B. Braun), as well as Velosorb Fast (Covidien/Medtronic). As a verified competitor reference, the code C1049630 of Safil Quick (B. Braun) corresponds to a 3/0 thread of 45 cm with a ⅜ reverse cutting needle, but with a 19 mm needle: it is comparable by category, not interchangeable 1:1, because the needle size differs (24 mm in this data sheet). Always verify material, gauge, needle length, curvature and point in the technical data sheet and the manufacturer’s IFU before substituting.

5. Selection tips and variants

Choose the needle size according to the tissue and surgical access: for skin and superficial planes, shorter needles (DS16 or DS19) are used, while the DS24 needle of this reference provides greater body length for thicker tissues or wide incisions. For the same PREMISUT RAPID Prime 3/0 family, presentations are available with DS16 needle of 75 cm (AMP222DS1630) and DS19 of 75 cm (AMP222DS1930), as well as gauges 4/0 (AMP222DS1940), 4/0 Fine (AMP221DS1940FN) and 5/0 (AMP222DS1950) for delicate tissues; in gauge 2/0 with DS24 needle and 75 cm there is the version AM222DS2420. For continuous sutures or approaches with straight needle, consult the GS60 variant (AMP222GS6030). The minimum order is 30 boxes; consult wholesale conditions for purchasing centres and distribution.

Additional information

Material

100% polyglycolic acid (PGAR) braided multifilament

Coating

Polycaprolactone and calcium stearate

Tensile strength

50% at 5 days; 0% at 14 days

Metric gauge (EP)

2 (Ph. Eur.)

Needle size

24 mm (DS24)

Needle tip

Triangular reverse cutting (reverse cutting)

Sterilisation

Gamma radiation

Presentation

Box of 12 units

Use

Tissue approximation, ligatures and general surgery

Medida de aguja

DS 24

Usp

3/0

Color

Colourless

Medida de hilo

45 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Estructura hilo

Braided multifilament

Absorcion

Rapid absorbable (≤ 45 days)