Description
1. Commercial Introduction
The multifilament absorbable suture PREMISUT RAPID of polyglycolic acid (PGAR) is the accelerated-absorption closure solution for general and ambulatory surgery operating theatres, emergency departments, digestive surgery, gynaecology and B2B purchasing centres that need a braided, flexible thread with an early and fully predictable loss of tensile strength. This reference combines a colourless 75 cm strand in USP gauge 2/0 with a needle with a ½-circle, cylindrical body and 26 mm trocar point (tapercut): firm penetration in medium-consistency tissues with a clean, controlled passage, minimising trauma to the puncture bed. Sterile, ready-to-use product, supplied in a box of 12 units in individual sachets with batch traceability. Ideal for hospital replenishment, clinics, distribution and tenders seeking a high-performance fast absorbable suture with an excellent quality-price ratio.
2. Technical Explanation
Polyglycolic acid (PGAR) is a synthetic polymer that is 100 % absorbable by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate, a coating that reduces friction when passing through tissues, improves thread glide and facilitates firm, secure knotting, with minimal tissue reaction. In its RAPID variant (low molecular weight), absorption occurs by hydrolysis —a predictable process independent of the patient’s enzymatic activity— within 40 to 45 days: it retains approximately 50 % of the initial tensile strength at 5 days and loses it completely at 14 days. This short support window makes it suitable for fast-healing tissues, minimising residual foreign material and avoiding the need for suture removal.
The HRT26 needle features a ½-circle (1/2, 160°) curvature with a cylindrical body and trocar point (tapercut): the round body allows clean passage through soft tissues, while the sharp triangular point perforates dense or poorly distensible tissues (aponeurosis, fascia, muscle, organ walls) in a controlled manner and without the wide cutting effect of a conventional cutting needle. Its 26 mm length makes it suitable for medium-depth planes and ligatures. USP gauge 2/0 (metric 3) provides an optimal balance between strength and fineness. Gamma radiation sterilisation guarantees final sterility with minimal alteration of mechanical properties; single-use product, not resterilisable.
3. Technical Specifications
3.1. General characteristics (Ref. 222HRT2620 · SKU AM222HRT2620)
| Parameter | Specification |
| Factory reference | 222HRT2620 (nomenclature PREMISUT RAPID) |
| Reference Cahnos (SKU) | AM222HRT2620 |
| Brand / quality | PREMISUT RAPID (standard range) |
| Thread material | 100 % polyglycolic acid (PGAR), braided multifilament |
| Thread structure | Braided (multifilament), smooth finish |
| Coating | Polycaprolactone and calcium stearate |
| Absorption | Rapid by hydrolysis, completed between 40 and 45 days |
| Tensile strength retention | 50% at 5 days; 0% at 14 days |
| Gauge / size | USP 2/0 (metric 3 / EP 3), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.30 – 0.339 mm |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Colourless |
| Needle shape | ½ circle (1/2, 160°), cylindrical body |
| Needle tip | Trocar / Tapercut (triangular point) |
| Needle size | HRT 26 (26 mm), 1 needle per suture |
| Swaged | 1 needle / 1 suture per unit |
| Sterilisation | Gamma radiation; sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot security |
| Indications | Approximation of soft tissues, ligatures, general surgery and moderate tension planes |
| Commercial presentation | Box of 12 units (sterile individual sachets); minimum order of 30 boxes; batch traceability |
| Regulatory standard | Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR) |
3.2. Decoding of the official reference
The official reference 222HRT2620 is decoded as: 222 (75 cm thread) + HRT26 (½-circle needle with cylindrical body and 26 mm trocar point) + 20 (USP gauge 2/0). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
3.3. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Total absorption | 40–45 days, by hydrolysis (predictable and uniform rate) |
The cited retention profile corresponds to the rapid-absorption formulation (RAPID line); it must not be confused with standard-absorption polyglycolic acid (60–90 days) or with standard polyglactin 910 (56–72 days), also available in our catalogue.
3.4. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 1 | 4 | 0.40 – 0.499 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 2/0 (this product) | 3 | 0.30 – 0.339 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
The strand diameter complies with the official USP Pharmacopeia ranges for synthetic absorbable sutures, without extending their limits.
4. Equivalences and Cross-References
Reference 222HRT2620 corresponds to the official nomenclature of the PREMISUT RAPID range (rapid-absorption polyglycolic acid, multifilament, USP 2/0, colourless 75 cm thread, ½-circle cylindrical needle with 26 mm trocar point). Rapid-absorption polyglycolic acid (PGAR) is one of the most widely used braided absorbable suture families on the market and can be homologated at clinical category level with the rapid-absorption lines of the major manufacturers. Only the reference whose full code and attributes have been verified against the manufacturer’s official catalogue and authorised distribution sources is included:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless) | VR917 (EMEA: family W9962) | Comparable by category (not interchangeable 1:1) | They match: rapid absorption (≈42 days), USP gauge 2/0, colourless colour and tapercut trocar point family. They differ: needle size (36 mm V-34 vs 26 mm HRT26), thread length (90 cm vs 75 cm) and base polymer (polyglactin 910 vs polyglycolic acid). Code confirmed in Ethicon’s EMEA catalogue and authorised distributors. Verify geometry in the official data sheet before substituting. |
The remaining homologous lines in the rapid-absorption segment —Safil Quick and Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI)— must be reviewed property by property (material, USP gauge 2/0, multifilament structure, ½-circle curvature, trocar point family, 26 mm needle length, 75 cm strand length, colourless colour, 1 needle attachment and CE/MDR regulatory classification) before any substitution; their codes for this exact configuration are pending confirmation with each manufacturer and are not published as definitive data. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Within the PREMISUT system itself, the PGAR RAPID family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other provided the needle gauge and geometry are respected.
5. Selection tips and variants of interest
USP gauge 2/0 (metric 3) offers an optimal balance between strength and fineness, indicated for tissues under moderate tension: skin, subcutaneous tissue, mucosa and soft tissue in general, as well as for ligation of small-calibre vessels. The HRT26 ½-circle needle with trocar point combines the penetration of a sharp point with the atraumatic passage of a cylindrical body: it is the recommended option when firm penetration without a broad cutting effect is required in medium-consistency tissues. The undyed version offers maximum discretion in the surgical field and is preferred in superficial or aesthetic tissue areas.
| SKU | Variant |
| AMP222HRT2620 (P222HRT2620) | PGAR RAPID Prime – HRT26 trocar point – USP 2/0 undyed – 75 cm (same configuration, Prime quality; direct equivalent within the same manufacturer) |
| AM222HRT3620 (222HRT3620) | PGAR RAPID – HRT36 trocar point – USP 2/0 undyed – 75 cm (longer needle, same gauge) |
| AM222HRT3610 (222HRT3610) | PGAR RAPID – HRT36 trocar point – USP 0 undyed – 75 cm (same geometry, larger gauge) |
| AM222HR3620 (222HR3620) | PGAR RAPID – HR36 taperpoint – USP 2/0 undyed – 75 cm (conical point for lax tissues) |
| AM222HR2630 (222HR2630) | PGAR RAPID – HR26 conical point – USP 3/0 undyed – 75 cm (finer gauge, conical point) |
| AM2L22HRT3620 (2L22HRT3620) | PGLAR Polyglactin 910 RAPID – HRT36 trocar point – USP 2/0 undyed – 75 cm (same absorption profile, glycolide/L-lactide copolymer) |
Sterility and storage: sterile product by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each use and keep the reference 222HRT2620 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.