Description
1. Product Presentation
The multifilament absorbable suture PREMISUT RAPID Prime (PGAR) is the reference surgical closure solution when the procedure requires short-term wound support, fully predictable resorption and excellent tissue handling. Made from 100% high-purity polyglactic acid in Prime quality, it offers firm penetration, secure knotting and minimal tissue reaction.
Its ½ circle needle with cylindrical body and trocar point (tapercut) of 26 mm (HRT26 series) combines the atraumatic penetration of a round body with a sharpened tip that passes through firm or inelastic tissues without tearing or enlarging the exit hole. It is presented in B2B format in a box of 12 units, designed for continuous supply to operating theatres, general surgery departments, clinics and purchasing centres.
2. Technical Explanation
Polyglactic acid (PGAR) is a 100% absorbable synthetic polymer presented in a braided multifilament structure, coated with polycaprolactone and calcium stearate, which provides smooth passage through tissues, optimal thread sliding at the knot and firm, secure tying.
In its RAPID version (low molecular weight), absorption occurs by hydrolysis — chemical degradation in contact with tissue fluids, without depending on the patient’s enzymatic activity — within 40 to 45 days. It retains approximately 50% of its initial tensile strength at 5 days and loses it completely at 14 days, making it suitable for rapidly healing tissues, tissue approximation, ligatures and general surgery, where it is desirable to minimise residual foreign material.
The ½ circle needle (160°) with cylindrical body and trocar point (HRT26 profile, 26 mm) penetrates dense tissues without aggressive cutting effect, avoiding enlargement of the exit hole. The colourless thread offers maximum discretion on the surgical field, a quality especially valued in superficial planes. Gamma radiation sterilisation guarantees final sterility with minimal alteration of mechanical properties. Single-use product, not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet of the reference
| Parameter | Specification |
| Reference (SKU) | AMP222HRT2620 · Factory ref. P222HRT2620 (box of 12 units) |
| Brand / Quality | PREMISUT RAPID – PGAR Prime |
| Material | 100% polyglycolic acid (PGAR) absorbable by hydrolysis |
| Thread structure | Braided multifilament, undyed |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 2/0 (metric 3; approximate diameter 0.30–0.339 mm) |
| Thread colour | Colourless |
| Thread length | 75 cm |
| Needle shape | Half circle (1/2, 160°) |
| Needle body | Cylindrical |
| Needle tip | Trocar / Tapercut (triangular point) |
| Needle size | 26 mm (HRT26 Prime), 1 needle per thread |
| Swaged | 1 needle / 1 suture per unit |
| Absorption mechanism | Hydrolysis; complete between 40 and 45 days |
| Sterilisation | Gamma radiation – sterile, single-use, not resterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot security |
| Indications | Tissue approximation, ligatures and general surgery |
| Commercial format | Box of 12 units (individual sterile sachets) |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for synthetic absorbable sutures |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Total absorption | 40–45 days by hydrolysis (predictable and uniform rate) |
The retention profile corresponds to the rapid absorption formulation (RAPID line); it should not be confused with standard absorption polyglactin 910 (PGLA line, 56–72 days), also available in our catalogue.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 2/0 (this product) | 3 | 0.30 – 0.339 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding their limits.
4. Equivalences and Cross-References
Rapid absorption polyglactic acid (PGAR) belongs to the worldwide family of short-term braided multifilament absorbable sutures, whose international clinical reference is the VICRYL RAPIDE line (polyglactin 910), with which it shares the hydrolysis absorption mechanism and accelerated strength loss profile. Only the reference whose code and attributes have been verified in manufacturer and authorised distribution sources is included:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless) | VR917 (EMEA) | Comparable by category (not interchangeable 1:1) | They match in rapid absorption material (≈42 days), USP 2/0 gauge, colourless colour, and ½ circle needle with tapercut trocar point (V-34). They differ in needle size (36 mm vs. 26 mm HRT26) and thread length (90 cm vs. 75 cm). Code confirmed in Ethicon’s EMEA catalogue and authorised distributors. |
Among the homologous families in the rapid absorption segment without a verified cross-reference code for this exact configuration (USP 2/0 · 26 mm trocar needle · 75 cm) are Safil Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category, material and absorption profile; in all cases, gauge, point geometry, needle size and thread length must be confirmed before any substitution. Standard VICRYL (56–72 days absorption) is not equivalent to this RAPID version. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
The USP 2/0 gauge (metric 3) offers an optimal balance between strength and fineness, indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa and soft tissue in general, as well as for ligatures of small-calibre vessels. The 26 mm needle with trocar point (tapercut) is the recommended choice when firm penetration without a broad cutting effect is needed in tissues of medium consistency.
| Reference / Variant | Description |
| AM222HRT2620 (222HRT2620) | PGAR RAPID HRT26 – 2/0 colourless – 75 cm (standard quality, same configuration) |
| AMP222HRT2630 (P222HRT2630) | PGAR RAPID Prime HRT26 – USP 3/0 colourless – 75 cm (finer gauge) |
| AMP228HRT2610 (P228HRT2610) | PGAR RAPID Prime HRT26 – USP 0 colourless – 75 cm (larger gauge) |
| AMP222HRT3620 (P222HRT3620) | PGAR RAPID Prime HRT36 – USP 2/0 colourless – 75 cm (36 mm needle) |
| AMP223HRT4020 (P223HRT4020) | PGAR RAPID Prime HRT40 – USP 2/0 colourless – 90 cm (long trocar needle) |
| AMP2L28HRT2610 (P2L28HRT2610) | PGLAR RAPID Prime polyglactin 910 – HRT26 – USP 0 colourless – 70 cm (same absorption profile) |
If the protocol prefers even more atraumatic penetration in lax tissues, consider the conical point series (HR, taperpoint) from the same range; if a wider working field is required, consult the HRT36/HRT40 needles. The colourless version offers maximum discretion in the field; if greater visibility is needed, consult the same configuration in dyed thread on request. As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.