Description
1. Commercial Introduction
The absorbable multifilament PGAR RAPID suture in Prime quality (PREMISUT RAPID range) is the technical reference for procedures requiring short-term suture support, excellent handling and fully predictable absorption. Mounted with a ½ circle cylindrical body needle with trocar point (tapercut) of 48 mm (HRT48), USP gauge 2 and a 90 cm colourless fluted thread, it offers reliable performance in general surgery, ligatures and soft tissue approximation.
It is supplied in a box of 12 sterile units, aimed at hospitals, clinics, purchasing centres and surgical services in the B2B channel. The trocar point combines a cylindrical body with a sharp cutting tip: it penetrates firmly into moderately dense or fibrous tissues without tearing and without enlarging the exit hole.
2. Technical Explanation
Rapid polyglactic acid (PGAR) is an absorbable synthetic polymer that is reabsorbed by hydrolysis, i.e., by chemical degradation in contact with tissue fluids, without depending on enzymes. In its RAPID variant (low molecular weight), the loss of strength is accelerated in a programmed manner: it retains 50% of its tensile strength at 5 days and loses practically all its strength at 14 days, with complete absorption between 40 and 45 days and minimal tissue reaction.
Its braided multifilament structure, with a fluted finish and coating of polycaprolactone and calcium stearate, provides very smooth handling, controlled sliding and firm, secure knot tying. The product is supplied sterile by gamma radiation, is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics (Ref. AMP223HRT4802)
| Parameter | Specification |
| Thread material | 100% rapid polyglactic acid (PGAR), absorbable synthetic, low molecular weight variant |
| Structure | Braided coated multifilament, fluted finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 2 |
| Thread length | 90 cm |
| Colour | Colourless |
| Needle shape | Half circle (1/2, 160°) |
| Needle body | Cylindrical |
| Needle tip | Trocar (tapercut) |
| Needle size | 48 mm (HRT48) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Quality | Prime |
| Presentation | Box of 12 sterile units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % |
| 14 days | 0 % |
Complete absorption by hydrolysis between 40 and 45 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.
4. Equivalences and Cross-References
Rapid absorption polyglactic acid (PGAR) belongs to the family of accelerated degradation braided synthetic absorbables, together with low molecular weight polyglactin 910. The profile of this datasheet (PGAR RAPID, USP gauge 2, 90 cm colourless thread and ½ circle 48 mm needle with trocar/tapercut point) has been verified against public sources and authorised distributors. The verified references from other manufacturers are listed below; as the gauge differs (USP 2-0 versus USP 2 of this datasheet) they are not interchangeable 1:1 and should be considered comparable at category level:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE – braided rapid absorption polyglactin 910, colourless, ½ circle taperpoint needle 48 mm, 90 cm | W9978 | Comparable by category (not interchangeable 1:1) | Same rapid absorption composition (≈42 days) and same 48 mm needle, but in USP gauge 2-0 versus USP 2 of this reference. Code confirmed in authorised Ethicon distributors. |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE – braided rapid absorption polyglactin 910, colourless, ½ circle tapercut needle, 90 cm | W9962 | Comparable by category (not interchangeable 1:1) | Same rapid absorption family and tapercut point, but USP gauge 2-0 and V-34 needle (36 mm) versus USP 2 / HRT48 of this reference. Code confirmed in authorised distributors. |
As homologous reference ranges in the sector, the rapid absorption braided sutures from B. Braun (Safil Quick / NOVOSYN QUICK), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI) are listed, whose specific codes for the exact combination USP 2 / 48 mm trocar needle / 90 cm thread must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version.
There is no equivalence table validated by the manufacturer; consult with the technical department before using in tenders.
5. Selection tips and variants of interest
Before placing the order, check three parameters: the USP gauge (USP 2 is reserved for tissues requiring high initial strength; for delicate tissues fine gauges 4/0 to 2/0 are recommended), the needle geometry (the ½ circle with 48 mm trocar point is ideal for moderately resistant tissues and confined spaces, while the conical point is most common in lax tissues) and the thread length (90 cm, ideal for general surgery and material replenishment).
Within the same PGAR RAPID Prime range with trocar point you will find complementary configurations: the HRT 40 variant in USP gauge 2/0 (ref. AMP223HRT4020), the HRT 40 in standard quality, and the same geometry in conical taperpoint HR 48 (ref. AMP223HR4802). If the protocol requires longer support duration, consider the PGA family of standard polyglactic acid (absorption 60–90 days, ref. AMP123HR4802 or AMP113HRT4802 in violet); if maximum field visibility is needed, request the same configuration in dyed thread on demand.
As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions or volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.