We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGAR RÁPIDO 2/0 | ½ Circle Cylindrical Needle Tapercut Trocar Point 36 mm (HRT36) | Undyed Thread 90 cm | PREMISUT RAPID | Box of 12 units (Ref. 223HRT3620)

Original price was: 39,90 €.Current price is: 30,50 €.

Absorbable multifilament suture PGAR RÁPIDO (100% polyglactic acid) from the PREMISUT RAPID range, in USP 2/0 (metric 3) gauge and undyed 90 cm strand, mounted with a ½-circle cylindrical-body needle and Tapercut trocar point of 36 mm (HRT36): firm penetration in dense or poorly distensible tissues without tearing the puncture bed. Coated with polycaprolactone and calcium stearate for smooth sliding and secure knotting. Predictable absorption by hydrolysis in 40–45 days, with 50% retention of tensile strength at day 5 and 0% at day 14. Sterilised by gamma radiation, single-use, with minimal tissue reaction. Indicated for tissue approximation, ligatures and general surgery. Factory ref. 223HRT3620 · SKU AM223HRT3620. Price per box of 12 units (minimum order 30 boxes).

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM223HRT3620

Description

1. Commercial Introduction

The absorbable multifilament PGAR RAPID suture from PREMISUT is the accelerated absorption surgical closure solution designed for general surgery operating theatres, ambulatory surgery, day hospitals and B2B purchasing centres that need a braided, flexible thread with early and fully predictable loss of tensile strength. This configuration combines a 90 cm colourless multifilament strand in USP 2/0 gauge with a ½ circle needle, cylindrical body and 36 mm Tapercut trocar point (HRT36 profile): firm penetration in tissues of certain density with a clean passage without tearing the puncture bed. Sterile, ready-to-use product, presented in a box of 12 units in individual sachets with batch traceability. Ideal for hospital replenishment, clinics, distribution and tenders seeking a high-performance rapid absorbable thread with an excellent quality-price ratio.

2. Technical Explanation

Polyglactic acid (PGAR) is a 100% synthetic polymer absorbable by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves sliding and facilitates firm, secure knotting, with minimal tissue reaction. In its RAPID variant (low molecular weight), absorption occurs by hydrolysis —a predictable process independent of the patient’s enzymatic activity— within 40 to 45 days: it retains approximately 50% of the initial tensile strength at 5 days and loses it completely at 14 days. This short support window makes it ideal for rapidly healing tissues, minimising residual foreign material and avoiding thread removal.

The HRT36 needle features a ½ circle curvature (1/2 circular, 160°) with a cylindrical body and trocar point (Tapercut): the round body allows clean passage through soft tissues, while the sharp triangular point perforates dense or poorly distensible tissues (aponeurosis, fascia, muscle, organ walls) in a controlled manner without the broad cutting effect of a conventional cutting needle. Its 36 mm length makes it suitable for deeper planes, approximation of tissues under moderate tension and ligatures. USP 2/0 gauge (metric EP 3) provides an optimal balance between strength and fineness. Gamma radiation sterilisation guarantees final sterility with minimal alteration of mechanical properties; single-use product, not resterilisable.

3. Technical Specifications

Parameter Specification
Factory reference 223HRT3620 (PREMISUT RAPID nomenclature)
Reference Cahnos (SKU) AM223HRT3620
Brand / quality PREMISUT RAPID (standard range)
Thread material 100% polyglactic acid (PGAR), braided multifilament
Thread structure Braided (multifilament), smooth finish
Coating Polycaprolactone and calcium stearate
Absorption Rapid by hydrolysis, completed between 40 and 45 days
Tensile strength retention 50% at 5 days; 0% at 14 days
Gauge / size USP 2/0 (metric 3 / EP 3), conforming to USP/EP Pharmacopoeia
Approximate thread diameter 0.30 – 0.339 mm
Thread length 90 cm (free end, without loop)
Thread colour Colourless
Needle shape ½ circle (1/2 circular, 160°), cylindrical body
Needle tip Trocar / Tapercut (triangular)
Needle size HRT 36 (36 mm), 1 needle per suture
Swaged 1 needle / 1 suture per unit
Sterilisation Gamma radiation; sterile, single-use, not re-sterilisable
Indications Approximation of soft tissues, ligatures, general surgery and moderate tension planes
Commercial presentation Box of 12 units (sterile individual sachets); minimum order of 30 boxes; batch traceability
Regulatory standard Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR)

3.1. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
1 4 0.40 – 0.499 mm
0 3.5 0.35 – 0.399 mm
2/0 (this product) 3 0.30 – 0.339 mm
3/0 2 0.20 – 0.249 mm

The thread diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding its limits.

3.2. Tensile strength retention profile

Post-implantation time Retained tensile strength
5 days 50% of initial tensile strength
14 days 0% (total loss of tensile support)
Total absorption 40–45 days, by hydrolysis (predictable and uniform rate)

The cited retention profile corresponds to the rapid absorption formulation (RAPID line); it should not be confused with standard absorption polyglactin 910 (PGLA line, 56–72 days), also available in our catalogue.

3.3. Decoding of the official reference

Official reference 223HRT3620: 223 (90 cm thread) + HRT36 (½ circle needle with cylindrical body and 36 mm trocar point) + 20 (USP 2/0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or bidding.

4. Equivalences and Cross-References

Reference 223HRT3620 corresponds to the official nomenclature of the PREMISUT RAPID range (rapid absorption polyglactic acid, multifilament, USP 2/0, 90 cm colourless thread, ½ circle cylindrical needle with 36 mm Tapercut trocar point). Rapid absorption polyglactic acid (PGAR) is one of the most widespread braided absorbable suture families on the market and is comparable at clinical category level with the rapid absorption lines of major manufacturers. Only the reference whose code and complete attributes have been verified in the manufacturer’s official catalogue and in authorised distributor sources is included:

Manufacturer / Brand Family / Model Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (polyglactin 910, braided, colourless) W9962 (EMEA) Comparable by category (not interchangeable 1:1) They match: rapid absorption (≈42 days), USP 2/0 gauge, 90 cm colourless thread and ½ circle 36 mm needle with Tapercut point (V-34). They differ: the polymer (polyglactin 910: glycolide/L-lactide vs polyglactic acid), the braid coating and the packaging format (36 units in Ethicon). Code confirmed in Ethicon’s EMEA catalogue and authorised distributors.

The remaining homologous lines in the rapid absorption segment —Safil Quick and Novosyn Quick (B. Braun / Aesculap), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI)— must be reviewed property by property (material, USP 2/0 gauge, multifilament structure, ½ circle curvature, trocar point family, 36 mm needle length, 90 cm thread length, colourless colour, 1 needle configuration and CE/MDR regulatory classification) before any substitution; unverified cross-reference codes are not published. Standard VICRYL (56–72 day absorption) is not comparable to this RAPID version. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.

There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders. Within the PREMISUT system itself, the PGAR RAPID family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other respecting gauge and needle geometry.

5. Selection tips and variants of interest

The USP 2/0 (metric 3) gauge offers an optimal balance between strength and fineness, indicated for tissues under moderate tension: skin, subcutaneous tissue, mucosa and soft tissue in general, as well as for ligation of small-calibre vessels. The HRT36 ½-circle needle with trocar point combines the penetration of a cutting point with the non-traumatic passage of a cylindrical body: it is the recommended option when firm penetration is required without a wide cutting effect, especially in medium-consistency tissues. The undyed version offers maximum discretion in the surgical field and is preferred in superficial or aesthetic tissue areas.

Variant (SKU) Description
AM223HRT3620 (223HRT3620) PGAR RÁPIDO – HRT36 trocar point – USP 2/0 undyed – 90 cm (this product)
AMP223HRT3620 (P223HRT3620) PGAR RÁPIDO Prime – HRT36 trocar point – USP 2/0 undyed – 90 cm (same configuration, Prime range)
AM222HRT3620 (222HRT3620) PGAR RÁPIDO – HRT36 trocar point – USP 2/0 undyed – 75 cm (same geometry, less thread)
AM223HRT3610 (223HRT3610) PGAR RÁPIDO – HRT36 trocar point – USP 0 undyed – 90 cm (same needle and geometry, larger gauge)
AM223HR3620 (223HR3620) PGAR RÁPIDO – HR36 conical taper point – USP 2/0 undyed – 90 cm (conical point for soft tissues)
AM2L23HRT3620 (2L23HRT3620) PGLAR Polyglactin 910 RÁPIDO – HRT36 trocar point – USP 2/0 undyed – 90 cm (same geometry, glycolide/L-lactide copolymer)

Sterility and storage: sterile product by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each use and keep the reference 223HRT3620 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team of Cahnos.

Additional information

Material

100% polyglactic acid (PGAR), braided multifilament

Coating

Polycaprolactone and calcium stearate

Thread structure

Braided (multifilament), smooth finish

Gauge

USP 2/0 (metric 3 / EP 3)

Thread diameter

0.30 – 0.339 mm

Needle shape

½ circle (160°), cylindrical body

Needle tip

Trocar / Tapercut (triangular)

Needle size

HRT 36 (36 mm), 1 needle per suture

Swaged

1 needle / 1 suture per unit

Sterilisation

Gamma radiation; single-use, not re-sterilisable

Indications

Approximation of soft tissues, ligatures and general surgery

Presentation

Box of 12 units (minimum order 30 boxes)

Manufacturer reference

223HRT3620

Regulatory standard

USP/EP Pharmacopoeia; CE marking (MDR)

Medida de aguja

HRT 36

Usp

2/0

Color

Colourless

Medida de hilo

90 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGAR RÁPIDO 2/0 | ½ Circle Cylindrical Needle Tapercut Trocar Point 36 mm (HRT36) | Undyed Thread 90 cm | PREMISUT RAPID | Box of 12 units (Ref. 223HRT3620)”

Your email address will not be published. Required fields are marked *