We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGAR RÁPIDO | ½ Circle Cylindrical Body Needle Tapercut Trocar Point 36 mm (HRT36) · USP 0 (Metric 3.5) · Colourless Thread 90 cm · PREMISUT RÁPIDO · Box of 12 units

Original price was: 39,90 €.Current price is: 30,50 €.

Absorbable multifilament suture PREMISUT RÁPIDO (polyglactic acid / PGAR) for general surgery: ½-circle needle with cylindrical body and 36 mm Tapercut trocar point (HRT36), gauge USP 0 (metric 3.5), colourless thread of 90 cm and coating of polycaprolactone and calcium stearate for smooth sliding and secure knot. Predictable absorption by hydrolysis in 40–45 days: retains 50 % of tensile strength at day 5 and loses it at day 14. Sterilised by gamma radiation, single-use, with minimal tissue reaction. Factory reference 223HRT3610 · SKU AM223HRT3610. Price per box of 12 units; minimum order 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM223HRT3610

Description

1. Commercial Introduction

The absorbable multifilament suture PREMISUT RÁPIDO (100 % polyglactic acid / PGAR) is the accelerated absorption surgical closure solution designed for general surgery operating theatres, ambulatory surgery, day hospitals and B2B purchasing centres that need a braided, flexible thread with early and fully predictable loss of tensile strength. This configuration combines a colourless multifilament strand of 90 cm in USP 0 gauge with a ½ circle needle, cylindrical body and Tapercut trocar point of 36 mm (HRT36 profile): firm penetration into tissues of a certain density with a clean passage without tearing the puncture bed. Sterile, ready-to-use product, presented in a box of 12 units in individual sachets with batch traceability. Ideal for hospital replenishment, clinics, distribution and tenders seeking a high-performance rapid absorbable thread with an excellent quality-price ratio.

2. Technical Explanation

Polyglactic acid (PGAR) is a synthetic polymer 100 % absorbable by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves sliding and facilitates firm, secure knotting, with minimal tissue reaction. In its RÁPIDO variant (low molecular weight), absorption occurs by hydrolysis —a predictable process independent of the patient’s enzymatic activity— within 40 to 45 days: it retains approximately 50 % of the initial tensile strength at 5 days and loses it completely at 14 days. This short support window makes it suitable for rapidly healing tissues, minimising residual foreign material and avoiding thread removal.

The HRT36 needle features a ½ circle curvature (1/2 circular) with a cylindrical body and trocar point (Tapercut): the round body allows clean passage through soft tissues, while the sharp triangular point perforates dense or poorly distensible tissues (aponeurosis, fascia, muscle, organ walls) in a controlled manner and without the extensive cutting effect of a conventional cutting needle. Its 36 mm length makes it suitable for planes of a certain depth, approximation of tissues with moderate tension and ligatures. The USP 0 gauge (metric EP 3.5) provides the necessary strength for medium-high tension planes. Gamma radiation sterilisation guarantees final sterility with minimal alteration of mechanical properties; single-use product, not re-sterilisable.

3. Technical Specifications

Parameter Specification
Factory reference 223HRT3610 (PREMISUT RÁPIDO nomenclature)
Reference Cahnos (SKU) AM223HRT3610
Brand / quality PREMISUT RAPID (standard range)
Thread material 100 % polyglactic acid (PGAR), braided multifilament
Thread structure Braided (multifilament), smooth finish
Coating Polycaprolactone and calcium stearate
Absorption Rapid by hydrolysis, completed between 40 and 45 days
Tensile strength retention 50% at 5 days; 0% at 14 days
Gauge / size USP 0 (metric 3.5 / EP 3.5), conforming to USP/EP Pharmacopoeia
Approximate thread diameter 0.35 – 0.399 mm
Thread length 90 cm (free end, without loop)
Thread colour Colourless
Needle shape ½ circle (1/2 circular), cylindrical body
Needle tip Trocar / Tapercut (triangular)
Needle size HRT 36 (36 mm), 1 needle per suture
Swaged 1 needle / 1 suture per unit
Sterilisation Gamma radiation; sterile, single-use, not re-sterilisable
Indications Approximation of soft tissues, ligatures, general surgery and moderate tension planes
Commercial presentation Box of 12 units (sterile individual sachets); minimum order of 30 boxes; batch traceability
Regulatory standard Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR)

3.1. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
1 4 0.40 – 0.499 mm
0 (this product) 3.5 0.35 – 0.399 mm
2/0 3 0.30 – 0.339 mm
3/0 2 0.20 – 0.249 mm

The thread diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding their limits.

3.2. Tensile strength retention profile

Post-implantation time Retained tensile strength
5 days 50 % of initial tensile strength
14 days 0% (total loss of tensile support)
Total absorption 40–45 days, by hydrolysis (predictable and uniform rate)

3.3. Decoding of the official reference

Official reference 223HRT3610: 223 (90 cm thread) + HRT36 (½ circle needle with cylindrical body and 36 mm trocar point) + 10 (USP 0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.

4. Equivalences and Cross-References

Reference 223HRT3610 corresponds to the official nomenclature of the PREMISUT RÁPIDO range (rapid absorption polyglactic acid, multifilament, USP 0, colourless 90 cm thread, ½ circle cylindrical needle with 36 mm Tapercut trocar point). Rapid absorption polyglactic acid (PGAR) is one of the most widespread braided absorbable suture families on the market and can be homologated at clinical category level with the rapid absorption lines of major manufacturers. There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the following match is a functional comparison at category level and should not be treated as interchangeable 1:1 without prior technical validation:

Manufacturer / Brand Family / Model Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (polyglactin 910) undyed VR2218 Comparable by category (not interchangeable 1:1) It matches in USP 0 gauge, colourless 90 cm thread and ½ circle tapercut needle of 36 mm (V-34); they differ in the polymer (polyglactin 910: glycolide/L-lactide versus polyglactic acid/PGA of this reference), the braid coating and the manufacturer. Code confirmed in the official Ethicon catalogue and authorised distributors.

Homologous families in the segment that must be reviewed property by property (material, USP 0 gauge, multifilament structure, ½ circle curvature, trocar point family, needle length 36 mm, thread length 90 cm, colourless colour, 1 needle configuration and CE/MDR regulatory classification) before any substitution: VICRYL RAPIDE® (Ethicon / J&J MedTech), Safil Quick® (B. Braun / Aesculap), DemeCRYL Fast (DemeTECH) and the rapid PGA ranges of European distribution. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference; no unverified cross-reference codes are published. Standard VICRYL (absorption 56–72 days) is not comparable to this RÁPIDO version.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering. Within the PREMISUT system itself, the PGAR RÁPIDO family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other respecting gauge and needle geometry.

5. Selection tips and variants of interest

USP 0 (metric 3.5) is a medium-high size indicated for planes with moderate tension: tissue approximation, ligatures, closure of deep planes, general surgery and minor surgery. The HRT36 ½-circle needle with trocar point combines the cutting penetration of a triangular point with the non-traumatic passage of the cylindrical body: suitable for dense or poorly distensible tissues (aponeurosis, fascia, muscle) without enlarging the puncture bed. The colourless colour facilitates direct visualisation of the surgical bed and is preferred in superficial or aesthetic tissue areas.

Variant (SKU) Description
AM223HRT3610 (223HRT3610) PGAR RÁPIDO – HRT36 trocar point – USP 0 colourless – 90 cm (this product)
AMP223HRT3610 (P223HRT3610) PGAR RÁPIDO Prime – HRT36 trocar point – USP 0 colourless – 90 cm (same configuration, Prime range)
AM222HRT3610 (222HRT3610) PGAR RÁPIDO – HRT36 trocar point – USP 0 colourless – 75 cm (same needle and gauge, less thread)
AM223HRT3620 (223HRT3620) PGAR RÁPIDO – HRT36 trocar point – USP 2/0 colourless – 90 cm (same geometry, smaller gauge)
AM223HR3610 (223HR3610) PGAR RÁPIDO – HR36 taperpoint conical point – USP 0 colourless – 90 cm (conical point for soft tissues)
AM2L23HRT3610 (2L23HRT3610) PGLAR Polyglactin 910 RÁPIDO – HRT36 trocar point – USP 0 colourless – 90 cm (same geometry, glycolide/L-lactide copolymer)

Sterility and storage: sterile product by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each use and keep reference 223HRT3610 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team of Cahnos.

Additional information

Material

100% Polyglactic acid (PGAR), braided multifilament

Coating

Polycaprolactone and calcium stearate

Gauge

USP 0 (metric 3.5 / EP 3.5)

Thread diameter

0.35 – 0.399 mm

Needle shape

1/2 circle (½ circular), cylindrical body

Needle tip

Trocar / Tapercut (triangular)

Needle size

HRT 36 (36 mm)

Swaged

1 needle / 1 suture per unit

Sterilisation

Gamma radiation; single-use, not re-sterilisable

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units (minimum order 30 boxes)

Manufacturer reference

223HRT3610

Regulatory classification

CE (MDR), conforming to USP/EP Pharmacopoeia

Medida de aguja

HRT 36

Usp

0

Color

Colourless

Medida de hilo

90 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Estructura hilo

Braided multifilament

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGAR RÁPIDO | ½ Circle Cylindrical Body Needle Tapercut Trocar Point 36 mm (HRT36) · USP 0 (Metric 3.5) · Colourless Thread 90 cm · PREMISUT RÁPIDO · Box of 12 units”

Your email address will not be published. Required fields are marked *