Description
1. Commercial Introduction
The PGAR RÁPIDO absorbable multifilament suture from the PREMISUT RÁPIDO range is the accelerated absorption closure solution for professionals who need a resorbable thread with predictable handling, secure knotting and complete disappearance from the body within a few weeks, without the need for stitch removal. This configuration combines a braided strand of 100 % polyglycolic acid in USP 2/0 gauge, colourless and 75 cm long, with a ½ circle needle with cylindrical body and Taperpoint conical point of 40 mm (HR40): atraumatic passage and minimal tissue damage, ideal for approximating soft tissues, ligatures and general surgery.
Sterile, ready-to-use product, presented in a box of 12 units in individual sachets with batch traceability. Aimed at hospital replenishment, purchasing centres, clinics and tenders seeking a rapid absorption thread with an excellent quality-price ratio.
2. Technical Explanation
The PGAR suture (rapid-profile polyglycolic acid) is a synthetic polymer that is 100 % absorbable by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves sliding and facilitates firm, secure knotting, with minimal tissue reaction and excellent initial tensile strength.
Its degradation profile is designed for short-term healing: it retains 50 % of tensile strength at 5 days and loses practically all its resistance at 14 days, completing absorption by hydrolysis between 40 and 45 days. The HR40 needle features a ½ circle curvature (1/2 circular, 160°) with a cylindrical body and Taperpoint conical point: the round body allows clean passage through soft tissues and the conical point separates fibres without an aggressive cutting effect, minimising trauma to the puncture bed. Its 40 mm length makes it suitable for medium-depth planes, subcutaneous tissue, aponeuroses and approximation of tissues under moderate tension. The USP 2/0 gauge (EP metric 3, diameter 0.30–0.339 mm) provides the optimal balance between handling and resistance. Sterile product by gamma radiation, single-use and non-resterilisable.
3. Technical Specifications
3.1. General characteristics (Ref. 222HR4020 · SKU AM222HR4020)
| Parameter | Specification |
| Factory reference | 222HR4020 (official nomenclature PREMISUT RÁPIDO) |
| Reference Cahnos (SKU) | AM222HR4020 |
| Brand / quality | PREMISUT RAPID (standard range) |
| Thread material | 100 % polyglycolic acid (PGAR), braided multifilament |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 2/0 (metric 3 / EP 3), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.30 – 0.339 mm |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Colourless (undyed) |
| Needle shape | ½ circle (1/2 circular, 160°), cylindrical body |
| Needle tip | Conical / Taperpoint (atraumatic) |
| Needle size | HR 40 (40 mm), 1 needle per suture |
| Swaged | 1 needle / 1 suture per unit |
| Absorption mechanism | Hydrolysis; complete between 40 and 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR) |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis (predictable and uniform rate) |
The cited retention profile corresponds to the rapid absorption formulation (RÁPIDO line); it should not be confused with standard absorption polyglycolic acid (60–90 days) or standard polyglactin 910 (56–72 days), also available in our catalogue.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 (this product) | 3 | 0.30 – 0.339 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
The strand diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without extending their limits.
3.4. Decoding of the official reference
The official reference 222HR4020 decodes as: 222 (75 cm thread) + HR40 (½ circle needle with cylindrical body and Taperpoint conical point of 40 mm) + 20 (USP 2/0 gauge). Cahnos markets the official reference without altering characters: no digit should be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
Reference 222HR4020 corresponds to the official nomenclature of the PREMISUT RÁPIDO range (rapid absorption polyglycolic acid, multifilament, USP 2/0, colourless 75 cm thread, ½ circle cylindrical needle with Taperpoint conical point of 40 mm). Rapid absorption polyglycolic acid (PGAR) is one of the most widespread short-duration braided absorbable suture families on the market, comparable at clinical category level with the rapid lines of major manufacturers (VICRYL RAPIDE from Ethicon / Johnson & Johnson MedTech, Safil Quick and Novosyn Quick from B. Braun / Aesculap, DemeCRYL Fast from DemeTECH and Surgicryl Fast Absorb from SMI).
The USP 2/0 · ½ circle conical point needle · 75 cm configuration has been compared against the segment’s reference catalogues: the closest homologous references from VICRYL RAPIDE differ in needle size, point family or gauge (e.g., V9450H/VR945 with CT-1 needle of 36 mm and 90 cm; VR917 with V-34 trocar point and 90 cm; VR9580 in USP 0 gauge), so none meets the required property-by-property match (USP 2/0 gauge, ½ circle curvature, Taperpoint conical point family, 40 mm needle size within ±1 mm tolerance, colourless 75 cm thread and 1-needle configuration).
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Verify in each official datasheet the USP 2/0 gauge (metric 3), the ½ circle curvature, the needle type and size (Taperpoint conical of 40 mm), the thread length (75 cm) and the colourless colour. Standard VICRYL (absorption 56–72 days) is not comparable to this RÁPIDO version. Within the PREMISUT system itself, the PGAR RÁPIDO family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other while respecting gauge and needle geometry.
5. Selection tips and variants of interest
The USP 2/0 gauge (metric 3) is a medium size that balances resistance and fineness, indicated for planes with moderate tension: approximation of subcutaneous tissue and fascia, closure of skin and mucous membranes, ligatures of small-calibre vessels and general surgery when wound support does not exceed 14 days. The HR40 ½ circle needle with Taperpoint conical point passes through soft tissues separating fibres without a cutting effect: it is the recommended option for lax, well-perfused tissues, where an atraumatic passage and minimal bleeding are sought. If the tissue is denser, consider the same family with Tapercut trocar point (HRT40) or reverse cutting. The colourless colour offers maximum discretion in the field and is preferred in aesthetic areas or superficial tissue.
| Variant (SKU) | Description |
| AM222HR4020 (222HR4020) | PGAR RÁPIDO – HR40 taper point – USP 2/0 undyed – 75 cm (this product, standard range) |
| AMP222HR4020 (P222HR4020) | PGAR RÁPIDO Prime – HR40 taper point – USP 2/0 undyed – 75 cm (same geometry and gauge, Prime quality) |
| AM222HR4010 (222HR4010) | PGAR RÁPIDO – HR40 taper point – USP 0 undyed – 75 cm (same needle, larger gauge) |
| AM223HR4010 (223HR4010) | PGAR RÁPIDO – HR40 taper point – USP 0 undyed – 90 cm (same needle, more thread) |
| AM222HR3620 (222HR3620) | PGAR RÁPIDO – HR36 taper point – USP 2/0 undyed – 75 cm (36 mm needle for medium fields) |
| AM222HR3020 (222HR3020) | PGAR RÁPIDO – HR30 taper point – USP 2/0 undyed – 75 cm (shorter needle, 30 mm) |
| AM222HRT4020 (222HRT4020) | PGAR RÁPIDO – HRT40 trocar point – USP 2/0 undyed – 75 cm (trocar point for denser tissues) |
Sterility and storage: sterile product by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each use and keep the reference 222HR4020 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews