Description
1. Commercial Introduction
PREMISUT RAPID is the accelerated absorption line from Cahnos for the professional who needs a resorbable thread with predictable handling, secure knotting and complete disappearance from the body within a few weeks, without the need to remove stitches. This Prime quality configuration combines a braided multifilament strand of polyglycolic acid (PGAR), colourless and 75 cm long, with a ½ circle needle with cylindrical body and 17 mm Taperpoint conical point (HR17 profile): the ideal choice for approximation of soft tissues, ligatures and general surgery, with an excellent quality-price ratio for hospital replenishment, purchasing centres and tenders.
2. Technical Explanation
The PGAR suture (rapid-profile polyglycolic acid) is a synthetic polymer that is 100% absorbable by hydrolysis, braided into a multifilament and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves sliding and facilitates firm, secure knotting, with minimal tissue reaction and excellent initial tensile strength.
Its degradation profile is designed for short-duration healing: it retains 50% of tensile strength at 5 days and loses practically all its resistance at 14 days, completing absorption by hydrolysis between 40 and 45 days. The HR17 needle has a ½ circle curvature (1/2 circular, 160°) with a cylindrical body and Taperpoint conical point: the round body passes through soft tissues atraumatically and the sharp conical point penetrates without aggressive cutting effect, avoiding enlargement of the exit hole. Its 17 mm length makes it especially suitable for reduced surgical fields, paediatric surgery, skin, subcutaneous tissue and mucous membranes. Product sterile by gamma radiation, single-use and non-reesterilisable.
3. Technical Specifications
3.1. General characteristics (Ref. P222HR1730 · SKU AMP222HR1730)
| Parameter | Specification |
| Factory reference | P222HR1730 (Prime range) |
| Reference Cahnos (SKU) | AMP222HR1730 |
| Brand / quality | PREMISUT RAPID (Prime range) |
| Thread material | 100% polyglycolic acid (PGAR), synthetic absorbable, low molecular weight variant (RAPID) |
| Thread structure | Coated braided multifilament |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 3/0 (metric 2 / EP 2), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.20 – 0.249 mm |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Colourless (undyed) |
| Needle shape | ½ circle (1/2 circular, 160°), cylindrical body |
| Tip type | Taperpoint conical |
| Needle size | HR 17 Prime (17 mm), 1 needle per thread |
| Swaged | 1 needle / 1 suture per unit |
| Absorption mechanism | Hydrolysis; complete between 40 and 45 days |
| Tensile strength retention | 50% at 5 days / 0% at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking (MDR) |
3.2. Absorption profile and tensile strength retention
| Post-implantation time | Retained tensile strength |
| 5 days | 50% of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis (predictable and uniform rate) |
The cited retention profile corresponds to the rapid absorption formulation (RAPID line); it must not be confused with standard absorption polyglycolic acid (PGA line, 60-90 days) nor with standard polyglactin 910 (56-72 days).
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 5/0 | 1 | 0.10 – 0.149 mm |
The diameter of the strand complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding its limits.
4. Equivalences and Cross-References
The reference P222HR1730 corresponds to the official nomenclature of the PREMISUT RAPID range (rapid absorption polyglycolic acid, multifilament, USP 3/0, colourless 75 cm thread, ½ circle cylindrical needle with 17 mm Taperpoint conical point, Prime quality). Rapid absorption polyglycolic acid (PGAR) belongs to the worldwide family of short-duration braided absorbable sutures of the rapid-profile PGA/polyglactin type, whose international clinical reference is the VICRYL RAPIDE line (Ethicon / Johnson \u0026 Johnson MedTech). Only references whose complete code and attributes have been verified in the manufacturer’s catalogue and authorised distribution are included:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless) | VRI 215 H – USP 3/0, ½ circle cylindrical needle (SH) of 17 mm, colourless thread of 75 cm | Comparable by category (not interchangeable 1:1) | They match USP 3/0 gauge, colourless 75 cm thread, ½ circle curvature and 17 mm cylindrical needle with conical point; they differ in the polymer (polyglactin 910 versus polyglycolic acid) and the coating. Code verified in authorised distribution catalogue; check IFU before substituting. |
The remaining homologous lines in the rapid absorption segment (Safil Quick and Novosyn Quick from B. Braun / Aesculap, DemeCRYL Fast from DemeTECH and Surgicryl Fast Absorb from SMI) must be reviewed property by property —material, USP 3/0 gauge, multifilament structure, ½ circle curvature, conical point family, 17 mm needle length, 75 cm strand, colourless colour, 1 needle configuration and CE/MDR regulatory classification— before any substitution; unverified cross-reference codes are not published. Standard VICRYL (absorption 56-72 days) is not comparable to this RAPID version. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department of Cahnos before using in a tender. Within the PREMISUT system itself, the PGAR RAPID family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other respecting gauge and needle geometry.
5. Selection tips and variants of interest
The USP 3/0 gauge (metric 2) is a fine-medium size indicated for rapidly healing tissues: approximation of skin, subcutaneous tissue, mucous membranes, episiotomies, phimosis and paediatric surgery. The HR17 ½ circle needle with Taperpoint conical point combines the sharp entry of the point with the non-traumatic passage of the cylindrical body: it is the recommended option for reduced fields and soft tissues where an atraumatic passage is sought, without a broad cutting effect and with minimal bleeding. The colourless colour offers maximum discretion in the surgical bed.
| Variant (SKU) | Description |
| AMP222HR1730 (P222HR1730) | PGAR RAPID Prime – HR17 taperpoint – USP 3/0 colourless – 75 cm (this product) |
| AMP222HR1740 (P222HR1740) | PGAR RAPID Prime – HR17 taperpoint – USP 4/0 colourless – 75 cm (same needle geometry, smaller gauge) |
| AMP222HR1750 (P222HR1750) | PGAR RAPID Prime – HR17 taperpoint – USP 5/0 colourless – 75 cm (fine gauge for very delicate tissues) |
| AM222HR1730 (222HR1730) | PGAR RAPID standard – HR17 taperpoint – USP 3/0 colourless – 75 cm (standard range, same geometry and gauge) |
| AMP222HR2630 (P222HR2630) | PGAR RAPID Prime – HR26 taperpoint – USP 3/0 colourless – 70 cm (larger needle for wider fields) |
| AMP222DS1630 (P222DS1630) | PGAR RAPID Prime – DS16 reverse cutting (⅜ circle) – USP 3/0 colourless – 75 cm (triangular point for more fibrous tissues) |
Sterility and storage: sterile product by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each use and keep the reference P222HR1730 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from humidity and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team of Cahnos.





Reviews