Description
1. Commercial Introduction
PREMISUT RAPID is the accelerated absorption line from Cahnos for professionals who need a resorbable thread with predictable handling, secure knotting and complete disappearance from the body within a few weeks, without the need for suture removal. This configuration combines a braided multifilament strand of polyglycolic acid (PGAR), colourless and 75 cm long, with a ½ circle needle with cylindrical body and Taperpoint conical point of 36 mm (HR36 profile): the ideal choice for soft tissue approximation, ligatures and general surgery, with an excellent quality-price ratio for hospital replenishment, purchasing centres and tenders.
2. Technical Explanation
The PGAR suture (rapid-profile polyglycolic acid) is a synthetic polymer that is 100% absorbable by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves sliding and facilitates firm, secure knotting, with minimal tissue reaction and excellent initial tensile strength.
Its degradation profile is designed for short-duration healing: it retains 50% of tensile strength at 5 days and loses practically all its resistance at 14 days, completing absorption by hydrolysis between 40 and 45 days. The HR36 needle has a ½ circle curvature (1/2 circular, 160°) with a cylindrical body and Taperpoint conical point: the round body passes through soft tissues atraumatically and the conical point penetrates without aggressive cutting effect, avoiding enlargement of the exit hole. The USP 1 gauge (metric 4) provides high initial resistance for planes with medium-high tension. Product sterile by gamma radiation, single-use and non-reesterilizable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Factory reference | 222HR3601 (PREMISUT RAPID nomenclature) |
| Reference Cahnos (SKU) | AM222HR3601 |
| Brand / family | PREMISUT RAPID – PGAR (rapid polyglycolic acid) |
| Thread material | 100 % polyglycolic acid (PGAR), braided multifilament |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 1 (metric 4 / EP 4), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.40 – 0.499 mm |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Colourless |
| Needle shape | ½ circle (1/2 circular, 160°), cylindrical body |
| Tip type | Conical / Taperpoint |
| Needle size | HR36 (36 mm), 1 needle per suture |
| Swaged | 1 needle / 1 suture per unit |
| Absorption | By hydrolysis, completed between 40 and 45 days |
| Sterilisation | Gamma radiation; sterile, single-use, not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for synthetic absorbable sutures; CE marking |
3.2. Absorption profile and tensile strength retention
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis (predictable and uniform rate) |
The cited retention profile corresponds to the rapid absorption formulation (RAPID line); it should not be confused with standard absorption polyglycolic acid (60–90 days) or with standard polyglactin 910 (56–72 days).
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2 | 5 | 0.50 – 0.599 mm |
| 1 (this product) | 4 | 0.40 – 0.499 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
The strand diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding its limits.
3.4. Decoding of the official reference
The official reference 222HR3601 is decoded as: 222 (75 cm thread) + HR36 (½ circle needle with cylindrical body and Taperpoint conical point of 36 mm) + 01 (USP 1 gauge). Cahnos markets the official reference without altering characters: no digit should be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
The reference 222HR3601 corresponds to the official nomenclature of the PREMISUT RAPID range (rapid absorption polyglycolic acid, multifilament, USP 1, colourless 75 cm thread, ½ circle cylindrical needle with Taperpoint conical point of 36 mm). Rapid absorption polyglycolic acid (PGAR) is one of the most widespread braided absorbable suture families on the market and can be homologated at the clinical category level with the rapid lines of major manufacturers, particularly with the CT-1 series of VICRYL RAPIDE™. Only references whose code and complete attributes have been verified in the manufacturer’s official catalogue and authorised distribution are included:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | VICRYL RAPIDE™ (polyglactin 910, braided, undyed) | VR944 – USP 3/0, CT-1 ½ circle needle with conical point of 36 mm, colourless thread of 90 cm | Comparable by category (not interchangeable 1:1) | They match in rapid absorption profile (≈42 days), braided multifilament, ½ circle curvature, 36 mm conical point needle (CT-1), colourless colour and 1 needle configuration. They differ in gauge (USP 3/0 vs USP 1) and polymer (polyglactin 910 vs polyglycolic acid). Code confirmed in official Ethicon catalogue. |
| Ethicon (J&J MedTech) | VICRYL RAPIDE™ (polyglactin 910, braided, undyed) | VR945 – USP 2/0, CT-1 ½-circle conical-point 36 mm needle, undyed 90 cm suture | Comparable by category (not interchangeable 1:1) | They match in CT-1 36 mm conical point needle, colourless thread, ½ circle curvature and rapid absorption profile. They differ in gauge (USP 2/0 vs USP 1) and chemical composition (polyglactin 910 vs PGA). Code confirmed in official Ethicon catalogue. |
The W9964 reference from VICRYL RAPIDE (USP 1, ½ circle 36 mm needle) is marketed with a Tapercut trocar point and 90 cm thread, so it differs in point family and strand length and cannot be considered 1:1 interchangeable with this configuration. The remaining homologous lines in the rapid absorption segment (Safil Quick and Novosyn Quick from B. Braun / Aesculap, DemeCRYL Fast from DemeTECH and Surgicryl Fast Absorb from SMI) must be reviewed property by property —material, USP 1 gauge, multifilament structure, ½ circle curvature, Taperpoint conical point, 36 mm needle length, 75 cm strand, colourless colour, 1 needle configuration and CE/MDR regulatory classification— before any substitution; no unverified cross-reference codes are published. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
There is no manufacturer-validated equivalence table that cross-references this reference with other brands; consult the technical department of Cahnos before using in tenders. Within the PREMISUT system itself, the PGAR RAPID family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other as long as gauge and needle geometry are respected.
5. Selection tips and variants of interest
USP 1 (metric 4) is a large size indicated for planes under considerable tension: approximation of soft tissues of some consistency, ligation of medium-calibre vessels, closure of deep planes and general surgery when wound support does not exceed 14 days. The HR36 ½-circle needle with Taperpoint conical point combines the sharp entry of the point with the non-traumatic passage of the cylindrical body: it is the recommended option for soft, well-perfused tissues, where an atraumatic passage is sought, without a broad cutting effect and with minimal bleeding. The colourless colour offers maximum discretion in the surgical field; if greater visibility is required, consider the same configuration in dyed thread on request.
| Variant (SKU) | Description |
| AM222HR3601 (222HR3601) | PGAR RAPID – HR36 Taperpoint conical point – USP 1 colourless – 75 cm (this product, standard range) |
| AMP222HR3601 (P222HR3601) | PGAR RAPID Prime – HR36 Taperpoint conical point – USP 1 colourless – 75 cm (same configuration, Prime quality) |
| AMP223HR3601 (P223HR3601) | PGAR RAPID Prime – HR36 Taperpoint conical point – USP 1 colourless – 90 cm (same needle and gauge, longer thread) |
| AM222HR3610 (222HR3610) | PGAR RAPID – HR36 conical point – USP 0 colourless – 75 cm (same needle geometry, smaller gauge) |
| AM222HR3620 (222HR3620) | PGAR RAPID – HR36 conical point – USP 2/0 colourless – 75 cm (medium gauge for moderate tension) |
| AM222HRT3620 (222HRT3620) | PGAR RAPID – HRT36 Tapercut trocar point – USP 2/0 colourless – 75 cm (trocar point for denser tissues) |
| AM2L22HR3601 (2L22HR3601) | PGLAR Polyglactin 910 RAPID – HR36 Taperpoint conical point – USP 1 colourless – 75 cm (same geometry, glycolide/L-lactide copolymer) |
Sterility and storage: sterile product by gamma radiation and single-use; check the integrity of the pouch and the expiry date before each use and keep reference 222HR3601 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.