Description
1. Commercial Introduction
The multifilament absorbable suture PREMISUT RAPID Prime is the accelerated absorption closure solution for operating theatres in general surgery, emergency departments, major ambulatory surgery and B2B purchasing centres that require a braided, flexible thread with early, predictable and fully documented loss of strength. This reference combines a 100% polyglycolic acid (PGAR) strand in USP 1 gauge, undyed and 90 cm, mounted with a ½ circle needle with cylindrical body and blunt point of 40 mm (HRN 40): the ideal atraumatic choice for tissue approximation, ligatures and general surgery procedures, with excellent value for money for hospital restocking, clinics and tenders.
2. Technical Explanation
Polyglycolic acid (PGAR) is a synthetic polymer that is 100% absorbable by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate, which reduces friction when passing through tissue, improves glide and facilitates firm, secure knotting. In its rapid absorption variant (RAPID, low molecular weight), degradation occurs by hydrolysis — a predictable process independent of the patient’s enzymatic activity — over a period of 40 to 45 days, with retention of 50% of initial tensile strength at 5 days and total loss of tensile support at 14 days.
The blunt point needle separates and displaces fibres without cutting them, minimising tissue damage and reducing bleeding: a decisive clinical advantage in delicate, highly vascularised or friable tissues, and in procedures where surgeon and patient safety is a priority. The undyed thread (uncoloured) facilitates visualisation of the surgical bed and offers aesthetic advantages in superficial areas. The product is sterilised by gamma radiation, is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics (SKU AMP223HRN4001)
| Parameter | Specification |
| Thread material | 100% polyglycolic acid (PGAR), synthetic absorbable, low molecular weight variant (RAPID) |
| Thread structure | Coated braided multifilament |
| Coating | Polycaprolactone and calcium stearate |
| Quality | Prime (PREMISUT RAPID range) |
| Gauge | USP 1 (metric 4; approx. diameter 0.40–0.499 mm according to Pharmacopoeia) |
| Thread colour | Colourless (undyed) |
| Thread length | 90 cm |
| Needle shape | Half circle (1/2, 160°) |
| Needle body | Cylindrical |
| Needle tip | Roma (blunt point) |
| Needle size | HRN 40 mm (1 needle per suture) |
| Absorption mechanism | Hydrolysis; complete between 40 and 45 days |
| Tensile strength retention | 50% at 5 days / 0% at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Reference | SKU Cahnos AMP223HRN4001 (factory reference not published in public sources; confirm for tender) |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50% of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40–45 days by hydrolysis (predictable and uniform rate) |
The retention profile corresponds to the rapid absorption formulation (RAPID line); it should not be confused with standard absorption polyglycolic acid (PGA line, 60–90 days) nor with standard polyglactin 910 (56–72 days).
3.3. Reference decoding
SKU AMP223HRN4001: A (distribution brand) + M (multifilament) + P (Prime range) + 223 (90 cm thread) + HRN40 (½ circle needle with cylindrical body and blunt point of 40 mm) + 01 (USP 1 gauge). Cahnos markets the reference without altering characters: no digit should be added, removed or rearranged when ordering or tendering.
4. Equivalences and Cross-References
Rapid absorption polyglycolic acid (PGAR) belongs to the worldwide family of short-term braided absorbable sutures of the PGA/polyglactin rapid profile type, whose international clinical reference is the VICRYL RAPIDE line (Ethicon / Johnson \u0026 Johnson MedTech). The following reference has been cross-checked against the manufacturer’s own sources and authorised distributors; no reference should be considered 1:1 interchangeable without validation from the technical department.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | VICRYL RAPIDE – braided polyglactin 910 rapid absorption, undyed | W9964 – USP 1, ½ circle needle 36 mm tapercut point, 90 cm, undyed | Comparable by category (not interchangeable 1:1) | Matches in USP 1 gauge, undyed 90 cm thread, ½ circle curvature and rapid absorption profile (≈42 days); differ in needle size (36 mm vs HRN 40 mm), point type (tapercut vs blunt point) and polymer (polyglactin 910: 90% glycolide / 10% L-lactide vs PGA). Code confirmed in official Ethicon EMEA catalogue and authorised distributors. Check IFU before substituting. |
There is no equivalence table validated by the manufacturer; consult with the technical department before using in a tender. Comparable ranges in the rapid absorption segment include Safil Quick / NOVOSYN QUICK (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category, material and absorption profile, although for the exact combination USP 1 / blunt point needle HRN 40 mm / 90 cm thread, their specific codes must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version.
5. Selection tips and variants of interest
USP 1 gauge (metric 4) is indicated for tissues with medium to high tension requirements: fascia, aponeurosis, abdominal wall, ligation of medium-calibre vessels and approximation of thick tissues where good initial strength combined with rapid resorption is needed. The ½ circle blunt point needle of 40 mm is the recommended atraumatic choice in delicate, highly vascularised or friable tissues, as well as in deep fields where minimal tissue injury is prioritised. Always verify the USP gauge, needle size and thread length from the surgical report before finalising the order.
Within the same PGAR RAPID Prime range, Cahnos offers complementary configurations:
| Reference | Variant |
| AMP223HR4001 | PGAR RAPID Prime USP 1, conical point needle (taperpoint) HR 40 mm, undyed, 90 cm (for lax tissues) |
| AMP223HRT4001 | PGAR RAPID Prime USP 1, trocar point needle (tapercut) HRT 40 mm, undyed, 90 cm (for somewhat firmer tissues) |
| AMP223HR4010 / AMP223HR4002 | PGAR RAPID Prime with conical point HR 40 in USP 0 and USP 2 gauges, undyed, 90 cm |
| AMP223HR4801 | PGAR RÁPIDO Prime USP 1, HR 48 mm needle, undyed, 90 cm (larger radius for wide fields) |
| AMP2L23HRN4001 | PGLAR RÁPIDO (polyglactin 910) Prime USP 1, blunt point HRN 40 mm needle, undyed, 90 cm |
The undyed version offers maximum discretion in the field; if greater visibility is required, consider the same configuration in dyed thread on request. For longer tensile support, consider the standard PGA family (absorption 60–90 days) or PGLA polyglactin 910 (absorption 56–72 days). As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight and below 30 °C, recording the batch number for traceability in the operating theatre. For special B2B conditions, volume orders or equivalents from other manufacturers, contact the technical-commercial team at Cahnos.





Reviews