Description
Block 1 – Commercial introduction
PREMISUT RAPID is the short-term absorbable suture solution for the professional who needs rapid, predictable reabsorption with sufficient initial wound support during the critical healing phase. This reference combines a braided multifilament thread of rapid polyglycolic acid with a ½ circle needle and reverse cutting triangular point of 22 mm, offering firm penetration in high-density tissues (skin, mucosa) with lower risk of tearing. Presentation in a box of 12 units, sterile by gamma radiation and ready for the operating theatre.
Block 2 – Technical explanation of the product
It is a synthetic absorbable braided and coated multifilament suture, composed 100% of rapid-profile polyglycolic acid (PGAR). The coating of polycaprolactone and calcium stearate reduces friction, improves sliding through tissue and facilitates knot seating without compromising its safety. Absorption occurs by hydrolysis: the thread retains approximately 50% of its tensile strength at 5 days and loses practically all of it at 14 days, with reabsorption completing between 40 and 45 days. The colourless (undyed) colour allows clear visualisation of the surgical bed and provides aesthetic advantages in superficial areas. The HS 22 needle (½ circle, triangular body and point, reverse cutting) places the third cutting edge on the outer curvature, which reduces the risk of tissue cutting when tensioning the thread compared to a conventional cutting needle.
Block 3 – Technical specifications
| Parameter | Value |
| Thread material | 100% rapid polyglycolic acid (PGAR) braided multifilament |
| Coating | Polycaprolactone and calcium stearate |
| Type | Synthetic absorbable, short-term, braided and coated multifilament |
| Gauge | USP 2/0 (metric 3) |
| Thread length | 45 cm |
| Needle | ½ circle, 22 mm, reverse cutting triangular body and point (HS 22) |
| Colour | Colourless |
| Absorption | By complete hydrolysis, 40–45 days |
| Tensile strength retention | 5 days: 50% · 14 days: 0% |
| Sterilisation | Gamma radiation |
| Indications | Approximation and ligation of soft tissues, general surgery |
| Contraindications | Extended tissue, cardiovascular and neurological tissues, allergy to components |
| Presentation | Box of 12 units · Minimum order 30 boxes |
Block 4 – Equivalences and cross-references
This suture falls into the worldwide category of short-term synthetic absorbable multifilament sutures of rapid profile type PGA/polyglactin. The following reference from another manufacturer has been compared against the official catalogue and sources from authorised distributors:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE (polyglactin 910) colourless – needle X-1 CONV ½ circle 22 mm, 45 cm | W9935 | Comparable by category (not interchangeable 1:1) | It matches in needle geometry (½ circle 22 mm), thread length (45 cm), colourless colour and rapid absorption profile; it differs in gauge (USP 3/0 vs 2/0 of the Cahnos product), the point (conventional cutting vs reverse cutting) and the polymer (polyglactin 910: glycolide/L-lactide). |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE (polyglactin 910) colourless – needle PRIME PC-22 ½ circle 22 mm, 45 cm | W9927 | Comparable by category (not interchangeable 1:1) | Needle ½ circle of 22 mm with 45 cm and colourless with rapid absorption; it differs in gauge (USP 3/0 vs 2/0) and the point (conventional PRIME cutting vs reverse cutting). |
The Safil Quick family from B. Braun (low molecular weight polyglycolic acid, rapid absorption, multifilament) is the closest clinical profile counterpart, but a specific code equivalent to the combination 2/0 · 45 cm · HS22 could not be verified in public sources; code not verifiable in public sources; confirm with the manufacturer before use. There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders.
Block 5 – Selection advice and variants of interest
For requirements that require maintaining the same needle geometry (½ circle, reverse cutting triangular body and point) in 22 mm and 45 cm, within the PREMISUT RAPID family there is the PRIME quality version (same 2/0 configuration) and the variant in USP 3/0 gauge with identical needle and length. If the surgical technique requires other curves or points (⅜ circle, taperpoint conical point or straight), the PGAR family offers the same thread in multiple combinations of needle, gauge and length. Always verify the USP gauge, thread length and needle geometry required in your protocol before substituting one reference for another.