Description
1. About this suture
The Absorbable Multifilament PGA Suture Without Needle USP 0 Violet 3×50 cm (factory ref. 11-3.5010 · SKU Cahnos AM11-3.5010) is the reference solution for B2B procurement for operating theatres, purchasing groups, general surgery clinics, ambulatory minor surgery services and healthcare distributors. Its presentation in sachets of 3 threads of 50 cm, without needle and in violet, makes it the natural choice for ligatures, tissue approximation and manual sutures, where the surgeon threads the strand onto the needle holder or ligature needle of their choice. It is a synthetic absorbable, sterile, single-use medical device with an excellent quality-price ratio for continuous supply to the facility: box of 12 units with a minimum order of 30 boxes.
2. Technical explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer with a long clinical track record, presented in a braided multifilament structure coated with polycaprolactone and calcium stearate. This configuration facilitates the passage of the thread through tissue, reduces the sawing effect, offers smooth handling and guarantees firm, secure knot tying in medium-tension gauges such as USP 0. Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, which is metabolised without causing significant tissue reaction. Complete absorption occurs between 60 and 90 days, maintaining the necessary tensile support during the critical phase of wound healing: 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. As it has no mounted needle, the strand is especially valued for vascular ligatures, closure of deep planes and procedures requiring maximum assembly flexibility. The violet colour ensures optimal visibility of the thread on the surgical field. The product is supplied sterile by ethylene oxide (EtO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference 11-3.5010
| Parameter | Specification |
| Brand / Range | Premisut (polyglycolic acid) |
| Factory reference | 11-3.5010 |
| SKU Cahnos | AM11-3.5010 |
| Composition | 100% polyglycolic acid (PGA), synthetic absorbable |
| Thread structure | Braided multifilament with coating |
| Coating | Polycaprolactone and calcium stearate |
| USP / metric gauge | USP 0 (metric EP 3.5) |
| Approximate thread diameter | 0.35 – 0.399 mm (according to USP/EP) |
| Thread colour | Violet (colourless version available in the family) |
| Length / presentation | 3 threads of 50 cm each, without needle |
| Absorption mechanism | Hydrolysis, 60 – 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units (individual sterile sachets); minimum order 30 boxes |
| Regulatory standard | USP / European Pharmacopoeia (EP) |
3.2. Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
| 2 weeks | 75% of the initial strength |
| 3 weeks | 50% of the initial strength |
| 4 weeks | 40% of the initial strength |
| Complete absorption | 60 – 90 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
| 2 | 5 | 0.50 – 0.599 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding its limits.
4. Equivalences and Cross-References
Coated braided multifilament polyglycolic acid (PGA) with medium absorption (60–90 days) is one of the most widely used absorbable suture families in general surgery, comparable at clinical category level with the needle-free ligature lines of major international manufacturers. The following homologous reference has been verified against manufacturer sources and authorised distribution:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| SMI (Belgium) | Surgicryl® PGA without needle | 11200015 (manufacturer’s ref.) | Comparable by category (not interchangeable 1:1) | Same principle: braided multifilament PGA coated with polycaprolactone and calcium stearate, violet, without needle, absorption 60–90 days by hydrolysis. The verified reference corresponds to USP 3/0 (EP 2) gauge in 150 cm format, different from the USP 0 in 3×50 cm of this datasheet; the declared retention profile varies by supplier. Verified in an authorised distributor catalogue with manufacturer data. |
Furthermore, other homologous families in the same category on the market are Safil® (B. Braun), of pure braided coated PGA with needle-free ligature presentations (GUDID cross-reference verified for the range in 5×70 cm formats: Safil Violet 2/0, ref. C1038446 — gauge and format different from those in this datasheet), Dexon / Dexon S (Medtronic), DemeSORB® PGA (DemeTECH), AssuCryl® (Assut Medical) and SERAFIT® (Serag-Wiessner), whose specific codes for needle-free format in USP 0 gauge must be confirmed with each manufacturer before any substitution. The VICRYL™ (Ethicon) and Novosyn® (B. Braun) ranges use polyglactin 910 (PGLA) copolymer, chemically different from PGA homopolymer and with an absorption profile of 56–72 days, so they are not interchangeable 1:1 without technical validation. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference; no unverified cross-reference codes are published.
There is no equivalence table validated by the manufacturer for this specific configuration (PGA without needle, USP 0, 3 threads of 50 cm, violet); consult the technical department of Cahnos before use in tenders. To substitute this reference in a specification, check one by one: exact material (PGA homopolymer), USP 0 gauge (EP 3.5), braided multifilament structure, needle-free presentation, thread length per sachet (50 cm), number of threads, colour and CE/MDR regulatory classification.
5. Selection tips and variants of interest
USP 0 gauge (metric EP 3.5) is the usual choice for ligatures of medium-calibre vessels, subcutaneous tissue and approximation of deep planes with moderate tension in general surgery. As it is a needle-free presentation, the thread can be threaded onto reusable ligature needles or freely combined according to the surgeon’s technique, optimising operating theatre stock.
| Variant (SKU) | Description |
| AM11-3.5010 (11-3.5010) | PGA without needle – USP 0 violet – 3 × 50 cm (this product) |
| AM11-3.4510 (11-3.4510) | PGA without needle – USP 0 violet – 3 × 45 cm |
| AM11-3.5030 (11-3.5030) | PGA without needle – USP 3/0 violet – 3 × 50 cm (smaller gauge) |
| AM11-3.5001 (11-3.5001) | PGA without needle – USP 1 violet – 3 × 50 cm (larger gauge) |
| AM11-5.7001 (11-5.7001) | PGA without needle – USP 1 violet – 5 × 70 cm (more strands per envelope) |
The violet colour favours visibility of the thread during the procedure, especially in bleeding fields; on request, the range offers colourless thread for maximum aesthetic discretion. As it is a sterile single-use product, always check the integrity of the sachet and the expiry date before each procedure, keep reference 11-3.5010 together with the batch number for traceability in the operating theatre and store in a cool, dry place, protected from sunlight and below 30 °C. For special B2B conditions, hospital supply contracts or consultation of additional gauges, lengths and colours, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.