Description
At Cahnos we offer the absorbable multifilament suture of polyglycolic acid (PGA) in Prime quality, reference P118GR1940 (SKU AMP118GR1940), a high-end professional solution for B2B supply to operating theatres, clinics and purchasing centres. This presentation combines a straight needle with cylindrical body and conical Taperpoint point of 19 mm (GR19), USP gauge 4/0 (metric 1.5) and a violet braided thread of 70 cm with non-grooved surface, soft feel and controlled passage through tissue.
It is the ideal choice for approximation of soft tissues, ligatures and general surgery, with predictable absorption that avoids the need for suture removal, reliable mechanical support during the first weeks of healing and special B2B ordering conditions for hospitals and volume buyers.
Technical explanation of the material and procedure
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer, structured as a braided multifilament coated with polycaprolactone and calcium stearate. This combination ensures smooth passage through tissue, low suture memory and firm, secure knot seating, even in fine gauges such as USP 4/0. With its non-grooved surface, the thread offers a very regular texture that reduces the sawing effect on tissue during passage.
Its absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable interval of 60 to 90 days. This profile maintains the necessary tensile strength during the first 2 to 4 weeks of healing, while the tissue recovers its own resistance.
The straight needle with cylindrical body and conical point (Taperpoint geometry) of 19 mm passes through tissue separating the fibres without cutting effect: it is the most atraumatic configuration for soft and friable tissues, with precise penetration and minimal tissue trauma along the path, ideal for manual suturing on directly accessible surfaces. The violet colour ensures optimal visibility of the thread throughout the procedure. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.
Technical specifications
3.1. Technical data sheet for reference AMP118GR1940
| Characteristic | Specification |
| Reference (SKU) | AMP118GR1940 |
| Factory reference | P118GR1940 |
| Quality | Prime (Premisut range) |
| Material | 100 % polyglycolic acid (PGA), synthetic absorbable |
| Coating | Polycaprolactone and calcium stearate |
| Suture type | Synthetic absorbable braided multifilament |
| Thread structure | Braided multifilament, non-grooved surface |
| USP / metric gauge | 4/0 (metric 1.5) |
| Approximate diameter | 0.15 – 0.199 mm (USP/EP standard) |
| Thread colour | Violet |
| Thread length | 70 cm |
| Needle shape | Straight |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | 19 mm (GR 19 Prime) |
| Absorption mechanism | Hydrolysis |
| Total absorption | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Regulatory standard | USP/EP |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
Equivalences and cross-references
Coated braided polyglycolic acid is the most established absorbable multifilament medium-absorption raw material in surgical practice (classic ‘Dexon’ type family). This Prime reference, with hydrolysis absorption of 60-90 days, tensile strength retention of 75/50/40% at 2/3/4 weeks and a straight Taperpoint conical-point needle of 19 mm, is comparable at category level (not interchangeable 1:1) with the following homologous PGA lines from other manufacturers, verified against official sources (manufacturer catalogue and/or GUDID database):
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| B. Braun | Safil® Violet (coated braided polyglycolic acid) | G1048008 / X1048008 – Safil Violet 4/0 (1.5), 70 cm, violet (verified in GUDID, DI 04038653944002 / 04038653965656) | Comparable by category (not interchangeable 1:1) | Same 100% PGA, same USP gauge 4/0, same length of 70 cm and violet colour; they differ in needle geometry (½ circle HR13 in Safil versus straight GR19 in this reference) and the coating specific to each manufacturer. |
| SMI (Belgium) | Surgicryl® PGA (coated braided multifilament, violet) | 11150113 – USP 4/0 (metric 1.5), ½ circle round body conical point HR 13 mm needle, 75 cm, violet (official SMI catalogue, Rev. 10) | Comparable by category (not interchangeable 1:1) | Same coated PGA polymer, same gauge and colour; they differ in needle geometry (½ circle HR13 versus straight GR19), thread length (75 cm versus 70 cm) and the commercial coding specific to each manufacturer. |
At category level, the following are also homologous coated braided PGA lines: DemeTECH DemeSORB® PGA, Assut AssuCryl® PGA and the historic Medtronic Dexon® / Dexon II® range. Ethicon Vicryl® / Vicryl Plus® (polyglactin 910) shares the multifilament behaviour and medium-absorption philosophy, but uses a different copolymer with absorption of 56-72 days, so it is not interchangeable 1:1 material for material. Any specific reference substitution must be validated code by code, verifying material, gauge, needle geometry (shape, body, point and size), thread length and presentation in the technical data sheet or IFU of each manufacturer.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The indicated correspondences are functional comparisons verified against official sources (manufacturer catalogue and GUDID) and must be confirmed code by code before a formal reference substitution. Within the Cahnos catalogue, the reference with identical configuration (straight GR19 needle, USP 4/0, violet, 70 cm, non-grooved) in polyglactin 910 (PGLA) is P1L18GR1940 (absorption 56-72 days).
Selection tips and variants of interest
Select the gauge according to the tissue and the tension the suture must withstand: USP gauge 4/0 (metric 1.5) is indicated for fine tissues and moderate tension, such as mucosa, subcutaneous tissue, delicate planes, ligatures and precision approximations in general surgery and minor ambulatory surgery. The straight needle with conical point of 19 mm is especially suitable for manual suturing on directly accessible surfaces where atraumatic penetration in soft tissues is prioritised.
Variants of interest in the Cahnos catalogue:
- P1L18GR1940: same needle geometry and gauge in polyglactin 910 (PGLA), absorption 56-72 days.
- AMP118GR1930: PGA Prime, straight needle GR19, USP 3/0, violet, 70 cm (intermediate gauge, larger diameter).
- AMP111GR1940-2: PGA Prime, double straight GR19 needle, USP 4/0, violet, 45 cm (double-thread presentation for bilateral surgery).
- AMP118DS1940FN: PGA Prime, ⅜ circle triangular point needle of 19 mm, USP 4/0, violet, 70 cm (for tissues of greater consistency).
- AMP228GR1940: PGAR Rapid, straight GR19 needle, USP 4/0, colourless, 70 cm (absorption 40-45 days, for short-term tissue support).
- AMP118GR4830: PGA Prime, straight conical-point needle of 48 mm for approaches with a longer needle.
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply to the healthcare facility. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or equivalents from other commercial brands, contact our technical-commercial team.





Reviews