Description
1. Product Presentation
The Prime-quality multifilament absorbable polyglycolic acid (PGA) suture is the reference surgical closure solution for hospitals, private operating theatres, clinics and procurement centres that require a synthetic absorbable suture with predictable behaviour, excellent handling and maximum knot security. This presentation is fitted with a ⅜ circle precision reverse cutting triangular-point needle with a 26 mm square body (XDS26 profile), USP 3/0 gauge and a 70 cm undyed suture, a configuration designed for aesthetic, plastic and reconstructive surgery, as well as for tissue approximation and ligation in general surgery.
Each unit is supplied sterile and ready to use, with the guarantee of professional distribution by Cahnos, in boxes of 12 units and B2B terms with a minimum order of 30 boxes. Article reference P128XDS2630 (SKU AMP128XDS2630).
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure, coated with polycaprolactone and calcium stearate. This configuration provides great flexibility, low shape memory and a reduced coefficient of friction that favours suture glide, handling and firm, secure knot tying, with high initial tensile strength.
Absorption occurs by hydrolysis, independent of the patient’s enzymatic activity, over a predictable period of 60 to 90 days. The suture retains 75% of its tensile strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks, just enough time for the tissue to regain its own strength. The ⅜ circle needle with reverse cutting triangular point and square body (precision profile) combines controlled penetration with minimal cutting effect, ideal for cutaneous planes and tissues requiring atraumatic passage and optimal scarring; the undyed suture offers a neutral aesthetic highly valued in cosmetic surgery. Sterile single-use product, not suitable for re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AMP128XDS2630
| Parameter | Specification |
|---|---|
| Reference (SKU) | AMP128XDS2630 |
| Factory reference | P128XDS2630 |
| Quality / Brand | Prime |
| Suture type | Absorbable synthetic multifilament |
| Material | 100% polyglycolic acid (PGA) |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament, non-ribbed |
| USP / metric gauge | 3/0 (metric 2) |
| Thread diameter | 0.20 – 0.249 mm (USP/EP standard) |
| Thread colour | Colourless |
| Thread length | 70 cm per unit |
| Needle shape | ⅜ circle (3/8) |
| Needle body | Square (plastic / cosmetic) |
| Needle tip | Precision reverse cutting triangular |
| Needle reference | XDS26 |
| Needle size | 26 mm |
| Swaged | 1 needle per suture |
| Absorption mechanism | Hydrolysis |
| Total absorption | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures, general surgery and aesthetic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Regulatory standard | USP / European Pharmacopoeia (EP) |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis |
4. Equivalences and Cross-References
Coated braided polyglycolic acid is the most proven absorbable multifilament medium-absorption raw material in surgical practice (classic ‘Dexon’-type family). In terms of composition (PGA homopolymer), braided structure, polycaprolactone and calcium stearate coating and hydrolysis absorption in 60–90 days, this reference is comparable at category level with the main PGA lines on the market. There is no manufacturer-validated equivalence table cross-referencing the XDS26 reference with other brands; the following correspondences have been checked against the official manufacturer catalogue and are functional comparisons, not 1:1 interchangeable:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| SMI (Belgium) | Surgicryl® PGA (braided coated polyglycolic acid, violet) | SM1120 1524 – USP 3/0, DS 24 mm 3/8 circle reverse cutting needle (official SMI catalogue) | Comparable by category (not interchangeable 1:1) | Same polymer (PGA), same coating (polycaprolactone and calcium stearate at 1%), same USP 3/0 gauge and same 3/8 reverse cutting needle family; the needle size differs (24 mm vs 26 mm of the XDS26 profile) and the colour (violet vs undyed). Verify IFU before substituting. |
| B. Braun (Aesculap) | Safil® Violet (coated braided polyglycolic acid) | C1048248 – SAFIL VIOLET 0 (3.5) 70CM DS30 (verified in official B. Braun catalogue) | Comparable by category (not interchangeable 1:1) | Same material (pure coated braided PGA), same 3/8 reverse cutting lancet needle geometry (DS) and 70 cm length; the gauge differs (USP 0 vs 3/0) and the needle size (30 mm vs 26 mm). It is cited as a DS family reference, not as a direct substitute. |
There is no manufacturer-validated equivalence table for this reference; consult the technical department before use in tenders. At category level, the following are also homologous coated braided PGA lines: DemeTECH DemeSORB® PGA, Assut AssuCryl® PGA and the historical Medtronic Dexon®/Dexon II® range; Ethicon Vicryl® (polyglactin 910) shares the multifilament behaviour and needle geometry, but has a different copolymer and absorption profile (56–72 days). In all cases, any substitution must be validated code by code, checking material, gauge, curvature, needle body and point, needle size, swaging, suture length and presentation in each manufacturer’s technical data sheet or IFU.
5. Selection tips and variants of interest
Select this suture when you need a fine-to-medium gauge (USP 3/0) with high handling and a precision needle for cutaneous planes and delicate tissues: the reverse cutting triangular point with square body (XDS26) penetrates with control and minimises tearing, making it a common choice in aesthetic, plastic and reconstructive surgery, as well as general surgery and ligation. The undyed suture is especially indicated when maximum aesthetic discretion is required in the suture bed.
- Same PGA Prime family with reverse cutting triangular needle: ref. AMP112DS3602 (DS36 needle, USP 2, violet, 75 cm) for larger gauges and greater suture length.
- Precision with atraumatic taper point: ref. AMP111DR9,360 (DR 9.3 mm needle, USP 6/0, violet, 45 cm) for mucosal, vascular and low-tension planes.
- Greater suture length with cutting needle: keep the PGA Prime material and consider 90 cm formats (e.g. AMP113DRN6401, blunt DRN 64 point, USP 1) depending on wound extent.
- Double needle for continuous sutures: ref. AMP118HR1730-2 (2xHR17, USP 3/0, violet, 2×70 cm) for anchoring at both ends.
- Material alternative: if the protocol requires longer wound support (180–210 days), consider the polydioxanone (PDO) family; for faster absorption, the fast-absorbing range (PGLAR type).
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply to the healthcare facility. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or equivalents from other commercial houses, contact our technical-commercial team.





Reviews
There are no reviews yet.