Description
1. Commercial Introduction
The absorbable multifilament polyglycolic acid (PGA) suture from the Premisult range, reference 111DS1950, is the trusted choice for the professional seeking a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security in tissue approximation, ligatures and general surgery. Its ⅜ circle needle with 19 mm reverse cutting triangular point (DS19) offers firm, controlled penetration in medium-consistency tissues, while the 45 cm violet braided grooved thread guarantees optimal visibility over the surgical field and smooth sliding during suturing.
It is a synthetic absorbable medical device, sterile and single-use, with an excellent price-performance ratio for B2B supply to operating theatres, purchasing centres and distributors of surgical material. Commercial presentation in a box of 12 units with a minimum order of 30 boxes.
2. Technical Explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, reduces the sawing effect, offers smooth handling and guarantees firm, secure knot tying, even in fine working gauges such as USP 5/0 (approximate diameter 0.10-0.149 mm).
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days and independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance that the body metabolises without generating relevant tissue reaction. The tensile strength retention profile maintains the necessary support during the critical phase of healing, while the tissue recovers its own resistance.
The ⅜ circle needle with reverse cutting triangular point (reverse cutting), body and point, 19 mm, penetrates firm, unyielding tissues —skin, muscle, scar tissue— with a clean cut and controlled trauma, without tearing. The violet colour improves thread visibility over the surgical field. The product is supplied sterile by ethylene oxide (EO), is single-use and is not resterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference 111DS1950
| Parameter | Specification |
| Brand / Range | Premisult (standard quality) |
| Catalogue reference | 111DS1950 |
| SKU Cahnos | AM111DS1950 |
| Composition | 100 % polyglycolic acid (PGA) absorbable by hydrolysis |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided coated multifilament, fluted finish |
| Gauge | USP 5/0 (metric 1); approximate diameter 0.10-0.149 mm (USP/EP) |
| Thread colour | Violet (also available undyed in the range) |
| Thread length | 45 cm |
| Needle shape | 3/8 circle (approx. 135°) |
| Tip type | Triangular with reverse cutting (inverted triangular / reverse cutting), body and point |
| Needle size | DS19 (19 mm) |
| Absorption mechanism | By hydrolysis, between 60 and 90 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units (minimum order 30 boxes) |
3.2. Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
| 2 weeks | 75% of initial strength |
| 3 weeks | 50% of initial strength |
| 4 weeks | 40% of initial strength |
| Complete absorption | 60-90 days by hydrolysis |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 5/0 | 1 | 0.10 – 0.149 mm (indicative according to USP/EP) |
4. Equivalences and Cross-References
Coated braided multifilament polyglycolic acid (PGA) with medium absorption (60-90 days) is one of the most widely used synthetic absorbables in general surgery. The homologous families by composition (coated PGA homopolymer), absorption profile, gauge, needle and colour that have been verified with reference code in public sources are as follows. As they are from other manufacturers, none is declared interchangeable 1:1 without validation by the technical service.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| B. Braun (Aesculap) | Safil® — pure polyglycolic acid, coated braided multifilament | C1048219 | Comparable by category (not interchangeable 1:1) | Material (100% PGA), USP 5/0 gauge, 45 cm violet thread and DS19 ⅜ circle reverse cutting needle match; the coating (glyconate vs polycaprolactone + calcium stearate), the house needle and the commercial presentation (usually 36 units) differ. Code verified in the medical device repository of B.Braun Surgical SA. |
| DemeTECH (USA) | DemeSORB® PGA (glycolide homopolymer, braided coated) | PGA185019F4P (DFS-2, 19 mm) | Comparable by category (not interchangeable 1:1) | Material (glycolic homopolymer coated with polycaprolactone and calcium stearate), USP 5/0 gauge, violet colour, 45 cm (18″) thread and 19 mm 3/8 circle reverse cutting needle match. Configuration confirmed in the official DemeTECH store and authorised distributors. The needle geometry (DFS-2 vs DS19) and the published retention profile (84% at 2 weeks / 23% at 4 weeks vs the Premisult profile) differ. |
| SMI (Surgical Materials Industries, Belgium) | Surgicryl® PGA (polyglycolic acid, braided multifilament coated with polycaprolactone and 1% calcium stearate) | 11101519 (DS-19, 19 mm, 75 cm) | Comparable by category (not interchangeable 1:1) | Material, coating, USP 5/0 gauge, violet colour and DS19 ⅜ circle reverse cutting needle match; the thread length differs (75 cm vs 45 cm): the official SMI catalogue does not publish the 5/0 + DS19 combination in 45 cm. Code verified in the manufacturer’s official catalogue. |
There is no equivalence table validated by the manufacturer for this specific configuration (multifilament PGA, ⅜ circle DS19 19 mm needle, reverse cutting triangular point, USP 5/0 gauge, 45 cm violet thread); consult the Cahnos technical department before use in tenders. Before substituting this reference in a tender specification, check one by one: material, USP gauge, needle size (19 mm), ⅜ curvature, point family (reverse cutting), thread length (45 cm) and colour. Copolymer polyglactin 910 (PGLA) ranges, such as Vicryl® from Ethicon, are chemically different from PGA homopolymer and are not interchangeable 1:1 without validation by the technical department. The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.
5. Selection tips and variants of interest
USP 5/0 gauge (metric 1) is indicated for fine and low-to-moderate tension tissues: soft tissue approximation, skin closures, subcutaneous planes, microsurgery and ligation of small-calibre vessels. The 19 mm DS19 needle with reverse cutting triangular point is recommended when firm tissues need to be penetrated without tearing in medium or reduced-size surgical fields. The violet colour favours thread visibility during the procedure; if maximum aesthetic discretion is preferred, a colourless version of the same configuration is available.
| Reference | Variant |
| AM111DS1950 (111DS1950) | PGA USP 5/0, ⅜ triangular DS19 mm needle, violet, 45 cm (current product) |
| AMP111DS1950 | PGA Prime quality, USP 5/0, same DS19 mm needle, violet, 45 cm (superior quality) |
| AM121DS1950 | PGA USP 5/0, same DS19 mm needle, colourless grooved, 45 cm (colourless variant) |
| AM112DS1950 | PGA USP 5/0, same DS19 mm needle, violet, 75 cm (longer length) |
| AM111DS1650 | PGA USP 5/0, triangular DS16 mm needle, violet, 45 cm (shorter needle) |
| AM111DS1940 | PGA USP 4/0, same DS19 mm needle, violet, 45 cm (smaller gauge) |
| 1L11DS1950 | PGLA (polyglactin 910) USP 5/0, same DS19 mm needle, violet, 45 cm (absorption 56-72 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. As this is a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours, contact the technical-commercial team at Cahnos.





Reviews