Description
1. About this suture
The Absorbable Multifilament PGA Prime Suture from the PREMISUT range, tariff reference P121DS1950, is the reference solution for B2B supply to operating theatres, purchasing centres and healthcare distributors. It combines a synthetic absorbable polyglycolic acid (PGA) thread with controlled absorption, exceptional handling and fully predictable clinical behaviour.
Mounted on a ⅜ circle needle with a 19 mm reverse cutting triangular point (inverted triangle) (DS19 Prime), it features gauge USP 5/0 (metric 1) and a 45 cm undyed fluted thread. It is indicated for tissue approximation, ligatures and general surgery, and is supplied as a sterile single-use medical device in a box of 12 units.
2. Technical explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer widely used in surgical sutures, presented here in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration facilitates the passage of the thread through tissue, reduces the sawing effect, offers smooth sliding and guarantees excellent knot security even in fine gauges such as USP 5/0 (approximate diameter 0.10-0.149 mm).
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance that the body metabolises without causing significant tissue reaction. The tensile strength retention profile maintains the necessary support during the critical healing phase, while the tissue recovers its own strength.
The 19 mm ⅜ circle needle with reverse cutting triangular point penetrates firm, fibrous and non-compliant tissues with controlled trauma and without tearing, making it especially suitable for closures of skin, fascia, aponeurosis, ligatures and reduced surgical fields. The undyed colour minimises visual interference on the surgical field, an advantage appreciated in aesthetic and reconstructive surgery. Sterilisation by ethylene oxide (EO); does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics of reference P121DS1950
| Parameter | Specification |
| Brand / Range | PREMISUT (Prime quality) |
| Catalogue reference | P121DS1950 |
| SKU Cahnos | AMP121DS1950 |
| Material | 100 % absorbable polyglycolic acid (PGA) |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 5/0 (metric 1) |
| Thread colour | Colourless |
| Thread length | 45 cm |
| Needle shape | 3/8 circle (approx. 135°) |
| Tip type | Triangular with reverse cutting (inverted triangular) |
| Needle size | DS19 (19 mm) Prime |
| Absorption mechanism | Hydrolysis (60-90 days) |
| Sterilisation | Ethylene oxide (EO), single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units (minimum order 30 boxes) |
3.2. Tensile strength retention profile
| Period | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
| Complete absorption | 60-90 days by hydrolysis |
Excellent initial tensile strength, optimal knot tying and fully predictable absorption rate, with minimal tissue reaction.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 5/0 | 1 | 0.10 – 0.149 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
The coated braided multifilament polyglycolic acid (PGA) with medium absorption (60-90 days) corresponds to the homologous families of the main manufacturers on the market: pure PGA is the material of the Safil (B. Braun) and Surgicryl (SMI) lines; the Novosyn (B. Braun) and Vicryl (Ethicon) ranges use polyglactin 910, a glycolide-based copolymer comparable by clinical category but not interchangeable 1:1 with pure PGA. References verified in manufacturer sources or regulated repertoires:
| Manufacturer / Brand | Family / Range | Code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun (Aesculap) | Safil® — pure polyglycolic acid, coated braided multifilament | C1049219 | Comparable by category (not interchangeable 1:1) | Safil undyed USP 5/0 (EP 1), 45 cm, DS19 reverse cutting needle. Matches in material, gauge, needle, length and colour; differs in coating (glyconate vs polycaprolactone) and commercial presentation. Code verified in the medical device repertoire of B.Braun Surgical SA. |
| B. Braun (Aesculap) | Novosyn® — polyglactin 910, coated braided multifilament | C0069219 | Comparable by category (not interchangeable 1:1) | Novosyn undyed 5/0 (1), 45 cm, DS19. Differs in material: polyglactin 910 (copolymer 90 % glycolide / 10 % L-lactide) vs pure PGA. Code verified in the official catalogue of B. Braun (Aesculap). |
| SMI (Surgical Materials Industries) | Surgicryl® PGA — polyglycolic acid, braided multifilament coated with polycaprolactone and calcium stearate | 11101512U | Comparable by category (not interchangeable 1:1) | Surgicryl PGA USP 5/0 (1), undyed, 45 cm, with DS12 reverse cutting needle. Matches in material, coating, gauge, length and colour; differs in needle size (DS12 vs DS19). The official SMI catalogue does not publish DS19 in gauge 5/0 at 45 cm. Code verified in official SMI catalogue. |
There is no equivalence table validated by the manufacturer for this specific configuration (PGA multifilament Prime, ⅜ circle DS19 mm reverse cutting needle, gauge USP 5/0, undyed 45 cm thread); consult with the technical department of Cahnos before using in a tender. Before replacing this reference in a specification, check one by one: material, USP gauge, needle size (19 mm), ⅜ curvature, point family (reverse cutting), thread length (45 cm) and colour. The brands cited belong to their respective manufacturers and are mentioned only as a reference for equivalence.
5. Selection tips and variants of interest
The USP 5/0 gauge (metric 1) is indicated for delicate and moderate tension tissues: thin skin, mucous membranes, subcutaneous tissue and fast-healing planes. The ⅜ circle needle with reverse cutting triangular point is recommended when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis). The undyed thread is chosen when maximum aesthetic discretion is sought; if maximum visibility in the surgical field is preferred, the same configuration is available in violet.
| Reference | Variant |
| AMP121DS1950 | PGA Prime, DS19, USP 5/0, undyed, 45 cm (current product) |
| AMP111DS1950 | PGA Prime, DS19, USP 5/0, violet, 45 cm (maximum visibility) |
| AMP112DS1950 | PGA Prime, DS19, USP 5/0, violet, 75 cm (greater length) |
| AMP122DS1950 | PGA Prime, DS19, USP 5/0, undyed, 75 cm (longer length) |
| AM121DS1950 | PGA standard quality, DS19, USP 5/0, undyed, 45 cm (economical alternative) |
| AMP121XDS1950 | PGA Prime, XDS19 precision needle with square body, USP 5/0, undyed, 45 cm |
| P1L21DS1950 | Polyglactin 910 (PGLA) Prime, DS19, USP 5/0, undyed, 45 cm |
| AMP321DS1950 | PGCL monofilament (polyglecaprone 25), DS19, USP 5/0, undyed, 45 cm (absorption 90-120 days) |
All references are supplied in a box of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours available on request, contact the technical-commercial team of Cahnos.