We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA (Polyglycolic Acid) Prime Suture PREMISUT | 3/8 Circle Needle Reverse Cutting Triangular Point DS19 (19 mm) | USP 3/0 (Metric 2) Gauge | Undyed Fluted 75 cm Thread | Ref. P122DS1930 | Box of 12 units

Original price was: 35,27 €.Current price is: 32,60 €.

Absorbable multifilament suture of polyglycolic acid (PGA) in Prime quality from the PREMISUT range, mounted on a ⅜ circle needle with reverse cutting triangular point, 19 mm (DS19). USP 3/0 (metric 2) gauge, undyed fluted 75 cm thread with polycaprolactone and calcium stearate coating. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and general surgery. Ref. P122DS1930 · SKU AMP122DS1930 · box of 12 units, minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP122DS1930

Description

1. Commercial Introduction

The absorbable multifilament suture PGA Prime (PREMISUT) is the reference solution for operating theatre services, purchasing centres and distributors looking for a synthetic absorbable polyglycolic acid thread with controlled absorption, excellent handling and fully predictable clinical performance. Its Prime quality guarantees a regular surface and smooth sliding that minimises tissue damage during suturing, with an excellent price-performance ratio for continuous B2B supply.

This presentation incorporates a ⅜ circle needle with reverse cutting triangular point (inverted triangular or reverse cutting) of 19 mm (DS19), USP 3/0 gauge (metric 2) and a 75 cm colourless grooved thread, ideal for tissue approximation, ligatures and general surgery. Sterile medical device, single-use, ready to use, in a box of 12 units. Manufacturer’s list reference P122DS1930 · SKU Cahnos AMP122DS1930.

2. Technical explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer widely used in surgical sutures, presented here in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This configuration facilitates the passage of the thread through tissue, reduces the sawing effect, offers smooth sliding and guarantees excellent knot security, even in medium working gauges such as USP 3/0.

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance that the body metabolises without causing relevant tissue reaction. The tensile strength retention profile maintains the necessary support during the critical phase of healing, while the tissue recovers its own resistance. Complete absorption occurs between 60 and 90 days.

The ⅜ circle needle with a 19 mm reverse cutting triangular point penetrates firm, fibrous and non-compliant tissues (skin, fascia, aponeurosis) with controlled trauma and without tearing, making it especially suitable for skin closures, soft tissue approximation, ligatures and reduced surgical fields. The colourless colour minimises visual interference on the surgical field. Sterilisation by ethylene oxide (EO); does not allow re-sterilisation.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Brand / Range PREMISUT (Prime quality)
Catalogue reference P122DS1930
SKU Cahnos AMP122DS1930
Material 100 % absorbable polyglycolic acid (PGA)
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 3/0 (metric 2)
Thread colour Colourless (also available in violet in the range)
Thread length 75 cm
Needle shape 3/8 circle (approx. 135°)
Tip type Triangular with reverse cutting (inverted triangular / reverse cutting)
Needle size DS 19 mm (Prime)
Absorption mechanism Hydrolysis (60-90 days)
Tensile strength retention 75% at 2 weeks · 50% at 3 · 40% at 4
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (minimum order 30 boxes)

3.2. Tensile strength retention profile

Period Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 40 %
Complete absorption 60-90 days by hydrolysis

Excellent initial tensile strength, optimal knot tying and fully predictable absorption rate, with minimal tissue reaction.

3.3. Size equivalence

USP size Metric size Approximate diameter
3/0 2 0.20 – 0.249 mm (indicative according to USP/EP)

4. Equivalences and Cross-References

The coated braided multifilament polyglycolic acid (PGA) with medium absorption (60-90 days) corresponds to the homologous families of the main manufacturers on the market: pure PGA is the material of the Safil® (B. Braun), Surgicryl® (SMI) and DemeSORB® (DemeTECH) lines; the Vicryl® (Ethicon, polyglactin 910) and Polysorb® (Medtronic, Lactomer) ranges are glycolide-based copolymers, comparable by clinical category but not interchangeable 1:1 with PGA homopolymer. The references cited below have been verified in official catalogues and authorised distributors of each manufacturer.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
SMI (Surgical Materials Industries, Belgium) Surgicryl® PGA (polyglycolic acid, braided multifilament coated with polycaprolactone and calcium stearate) 11201519U (colourless) / 11201519 (violet) Comparable by category (not interchangeable 1:1) Surgicryl PGA USP 3/0 (metric 2) with DS19 needle of ⅜ circle and reverse cutting of 19 mm, 75 cm thread; matches in material (100% PGA), coating (polycaprolactone and calcium stearate), gauge, needle, length and colour (colourless version 11201519U). Configuration confirmed in authorised SMI distributors (omega-medical and tammexmedical) and official manufacturer data sheet; box of 12 units.
DemeTECH (USA) DemeSORB® PGA (polyglycolic acid, braided coated with polycaprolactone and calcium stearate) PGA273019F4P (colourless) / PGA283019F4P (violet) Comparable by category (not interchangeable 1:1) DemeSORB PGA USP 3/0, 75 cm (30″) thread and DFS-2 needle of 3/8 circle with reverse cutting of 19 mm; matches in material (100% PGA coated with polycaprolactone and calcium stearate), gauge, length, colour (colourless version PGA273019F4P) and needle size. Configuration confirmed in official DemeTECH store and authorised distributors; verify needle geometry before substituting. Box of 12 units.
B. Braun (Aesculap) Safil® (pure polyglycolic acid, braided multifilament coated with polyglyconate) C1049421 (colourless, box of 36) Comparable by category (not interchangeable 1:1) Safil 3/0 (metric 2) colourless with DS19 (M) needle of ⅜ circle and reverse cutting of 19 mm, 70 cm thread; differs in length (70 cm vs 75 cm), coating (polyglyconate vs polycaprolactone) and presentation (36 units vs 12 units). Code confirmed in the official Safil brochure from B. Braun and authorised distributors.

There is no manufacturer-validated equivalence table for this specific configuration (Prime multifilament PGA, ⅜ circle DS 19 mm needle, reverse cutting triangular point, USP 3/0 gauge, 75 cm colourless thread); consult the technical department of Cahnos before use in tenders. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (19 mm), ⅜ curvature, point family (reverse cutting), thread length (75 cm) and colour. The copolymer ranges of polyglactin 910 (PGLA), such as Vicryl® from Ethicon, and Lactomer (Polysorb®, Medtronic), are chemically different from PGA homopolymer and are not interchangeable 1:1 without validation from the technical department. The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.

5. Selection tips and variants of interest

USP 3/0 (metric 2) gauge offers an ideal balance between initial strength and handling for tissues with moderate mechanical demands: soft tissue approximation, skin closures, subcutaneous planes and ligatures. The DS 19 mm needle with reverse cutting triangular point is indicated when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis) in medium or small surgical fields. The undyed suture is recommended when maximum aesthetic discretion over the surgical field is sought; if maximum visibility is preferred, a violet version of the same configuration is available.

Reference Variant
AMP112DS1930 PGA Prime, DS19, USP 3/0, violet, 75 cm (same configuration in violet colour)
AM122DS1930 PGA standard quality, DS19, USP 3/0, undyed, 75 cm (economical alternative)
AMP122DS1940 PGA Prime, DS19, USP 4/0, undyed, 75 cm (finer gauge)
AMP122DS2430 PGA Prime, DS24, USP 3/0, colourless, 75 cm (intermediate needle)
AMP122DS3030 PGA Prime, DS30, USP 3/0, undyed, 75 cm (larger needle)
AMP222DS1930 PGAR Rapid, DS19, USP 3/0, undyed, 75 cm (rapid absorption 40-45 days)
P1L22DS1930 PGLA (polyglactin 910) Prime, DS19, USP 3/0, undyed, 75 cm (absorption 56-72 days)
AMP322DS1930 PGCL monofilament (poliglecaprone 25), DS19, USP 3/0, undyed, 75 cm (absorption 90-120 days)

All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.

Additional information

Material

100 % absorbable polyglycolic acid (PGA)

Coating

Polycaprolactone and calcium stearate

Gauge

USP 3/0 (metric 2)

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Use

Single-use, not re-sterilisable

Presentation

Box of 12 units

Minimum order

30 boxes

Manufacturer reference

P122DS1930

Indications

Tissue approximation, ligatures and general surgery

Thread structure

Braided multifilament coated with fluted finish

Needle shape

3/8 circle (approx. 135°)

Tip type

Triangular with reverse cutting (reverse cutting)

Needle size

DS19 (19 mm) Prime

Absorption mechanism

Hydrolysis, 60-90 days

Tensile strength retention

75 % (2 wks) · 50 % (3 wks) · 40 % (4 wks)

Tissue reaction

Minimal

Medida de aguja

DS 19

Usp

3/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA (Polyglycolic Acid) Prime Suture PREMISUT | 3/8 Circle Needle Reverse Cutting Triangular Point DS19 (19 mm) | USP 3/0 (Metric 2) Gauge | Undyed Fluted 75 cm Thread | Ref. P122DS1930 | Box of 12 units”

Your email address will not be published. Required fields are marked *