We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA 4/0 Suture (Polyglycolic Acid) | 3/8 Circle Reverse Cutting Triangular Point Needle DS19 (19 mm) | Undyed Fluted Thread 75 cm | Ref. 122DS1940 | Box of 12 units

Original price was: 27,44 €.Current price is: 26,10 €.

Absorbable multifilament suture of polyglycolic acid (PGA) from the PREMISUT range, mounted on a ⅜ circle needle with a reverse cutting triangular point of 19 mm (DS19). USP gauge 4/0 (metric 1.5), undyed fluted thread of 75 cm with polycaprolactone and calcium stearate coating. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and general surgery. Ref. 122DS1940 · SKU AM122DS1940 · box of 12 units, minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM122DS1940

Description

1. Commercial Introduction

The absorbable multifilament polyglycolic acid (PGA) suture PREMISUT is the reference solution for operating theatre services, purchasing centres and distributors looking for a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security in tissue approximation, ligatures and general surgery.

This presentation incorporates a ⅜ circle needle with a reverse cutting triangular point (inverted triangular) of 19 mm (DS19), USP 4/0 gauge (metric 1.5) and a colourless fluted thread of 75 cm. Sterile medical device, single-use, ready to use, in a box of 12 units. Tariff reference 122DS1940 · SKU Cahnos AM122DS1940.

2. Technical Explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer widely used in surgical sutures, presented here in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration facilitates the passage of the thread through tissue, reduces the sawing effect, offers smooth sliding and guarantees excellent knot security, even in fine gauges such as USP 4/0.

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance that the body metabolises without causing significant tissue reaction. The tensile strength retention profile maintains the necessary support during the critical phase of healing, while the tissue recovers its own strength.

The ⅜ circle needle with a 19 mm reverse cutting triangular point penetrates firm, fibrous and non-compliant tissues (skin, fascia, aponeurosis) with controlled trauma and without tearing the planes, making it especially suitable for skin closures, soft tissue approximation, ligatures and reduced surgical fields. The colourless colour reduces visual interference on the surgical field to a minimum. Sterilisation by ethylene oxide (EO); does not allow re-sterilisation.

3. Technical Specifications

3.1. General characteristics of reference 122DS1940

Parameter Specification
Brand / Range PREMISUT (standard quality)
Catalogue reference 122DS1940
SKU Cahnos AM122DS1940
Composition 100 % Polyglycolic Acid (PGA), absorbable by hydrolysis
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 4/0 (metric 1.5)
Thread colour Colourless (also available in violet in the range)
Thread length 75 cm
Needle shape 3/8 circle (approx. 135°)
Tip type Triangular with reverse cutting (inverted triangular)
Needle size DS19 (19 mm)
Absorption mechanism Hydrolysis, between 60 and 90 days
Tensile strength retention 2 weeks 75 % · 3 weeks 50 % · 4 weeks 40 %
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (minimum order 30 boxes)

3.2. Tensile strength retention profile after implantation

Period Tensile strength retention
2 weeks 75% of initial strength
3 weeks 50% of initial strength
4 weeks 40% of initial strength
Complete absorption 60-90 days by hydrolysis

Excellent initial tensile strength, optimal knot tying and fully predictable absorption rate, with minimal tissue reaction.

3.3. Size equivalence

USP size Metric size Approximate diameter
4/0 1.5 0.15 – 0.199 mm (indicative according to USP/EP)

4. Equivalences and Cross-References

The coated braided multifilament polyglycolic acid (PGA) with medium absorption (60-90 days) corresponds to the homologous families of the main manufacturers on the market: pure PGA is the material of the Safil (B. Braun), Surgicryl (SMI) and DemeSORB (DemeTECH) lines; the Vicryl (Ethicon, polyglactin 910) and Polysorb (Medtronic, Lactomer) ranges are copolymers based on glycolide, comparable by clinical category but not interchangeable 1:1 with the PGA homopolymer. The references cited below have been verified in official catalogues or authorised stores of each manufacturer.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
SMI (Surgical Materials Industries, Belgium) Surgicryl® PGA (polyglycolic acid, braided multifilament coated with polycaprolactone and calcium stearate) 11151519U (colourless) / 11151519 (violet) Comparable by category (not interchangeable 1:1) Surgicryl PGA USP 4/0 (metric 1.5) with a DS19 needle of ⅜ circle and reverse cutting of 19 mm, thread of 75 cm; matches in material (100% PGA), coating, gauge, needle, length and colour (colourless version 11151519U). Configuration confirmed in the official SMI data sheet and authorised distributors; verify needle geometry before substituting. Box of 12 units.
DemeTECH (USA) DemeSORB® PGA (polyglycolic acid, braided coated) PGA274019F4P (colourless) / PGA284019F4P (violet) Comparable by category (not interchangeable 1:1) DemeSORB PGA USP 4/0, thread of 75 cm (30″) and a 3/8 circle reverse cutting needle DFS-2 of 19 mm; matches in material (PGA coated with polycaprolactone and calcium stearate), gauge, length, colour and needle size. Configuration confirmed in the official DemeTECH store and authorised distributors; verify needle geometry before substituting. Box of 12 units.
B. Braun (Aesculap) Safil® (pure polyglycolic acid, braided multifilament coated with polyglyconate) C0049420 (colourless, box of 36) Comparable by category (not interchangeable 1:1) Safil 4/0 (metric 1.5) colourless with a DS19 needle of ⅜ circle and reverse cutting of 19 mm; differs in thread length (70 cm vs 75 cm), coating (polyglyconate vs polycaprolactone) and presentation (box of 36 units vs 12 units). Code confirmed in the official Safil brochure from B. Braun and authorised distributors.

There is no equivalence table validated by the manufacturer for this specific configuration (multifilament PGA, ⅜ circle DS19 needle of 19 mm, reverse cutting triangular point, USP 4/0 gauge, colourless thread of 75 cm); consult the technical department of Cahnos before using in tenders. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (19 mm), curvature ⅜, point family (reverse cutting), thread length (75 cm) and colour. The copolymer ranges of polyglactin 910 (PGLA), such as Vicryl (Ethicon), and Lactomer (Polysorb, Medtronic) are chemically different from the PGA homopolymer and are not interchangeable 1:1 without validation from the technical department. The brands cited belong to their respective manufacturers and are mentioned solely as a reference for equivalence.

5. Selection tips and variants of interest

The USP 4/0 gauge (metric 1.5) is ideal for skin, subcutaneous tissue, low-tension soft tissues and ligatures, offering an excellent relationship between initial strength and handling. The DS19 needle of 19 mm with a reverse cutting triangular point is indicated when it is necessary to penetrate firm tissues without tearing in reduced surgical fields. The colourless thread is recommended when maximum aesthetic discretion on the surgical field is sought; if you prefer maximum visibility, there is a violet version of the same configuration.

Reference Variant
AM122DS1940 PGA USP 4/0, ⅜ triangular needle DS19, undyed, 75 cm (current product)
AM112DS1940 PGA USP 4/0, same DS19 needle, violet, 75 cm (violet variant)
AMP122DS1940 PGA Prime quality USP 4/0, DS19 needle, undyed, 75 cm (superior quality)
AM122DS1930 PGA USP 3/0, same DS19 needle, undyed, 75 cm (larger gauge)
AM122DS1640 PGA USP 4/0, DS16 needle, undyed, 75 cm (shorter needle)
AM222DS1940 PGAR rapid USP 4/0, DS19 needle, undyed, 75 cm (absorption 40-45 days)
1L22DS1940 PGLA (polyglactin 910) USP 4/0, DS19 needle, undyed, 75 cm (absorption 56-72 days)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. As this is a sterile single-use product, always check the integrity of the packaging before each procedure, store it in a cool, dry place away from direct sunlight, and respect the expiry date. For special B2B conditions, volume orders or enquiries about other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.

Additional information

Manufacturer reference

122DS1940

Material

100% Polyglycolic Acid (PGA) absorbable

Coating

Polycaprolactone and calcium stearate

Gauge

USP 4/0 (metric 1.5)

Tip type

Triangular with reverse cutting (inverted triangular)

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Tissue reaction

Minimal

Presentation

Box of 12 units

Minimum order

30 boxes

Intended use

Tissue approximation, ligatures and general surgery

Thread structure

Braided multifilament coated with fluted finish

USP size

4/0 (metric 1.5)

Needle size

DS19 (19 mm)

Needle shape

3/8 circle (approx. 135°)

Needle tip

Reverse cutting triangular (inverted triangular)

Medida de aguja

DS 19

Usp

4/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA 4/0 Suture (Polyglycolic Acid) | 3/8 Circle Reverse Cutting Triangular Point Needle DS19 (19 mm) | Undyed Fluted Thread 75 cm | Ref. 122DS1940 | Box of 12 units”

Your email address will not be published. Required fields are marked *