Description
1. Product Presentation
The Absorbable Multifilament PGA Prime 7/0 Suture is the precision reference your operating theatre service, ophthalmology unit or purchasing department needs for procedures requiring maximum fineness and predictable performance. It is fitted with a ⅜ circle spatulated Micropoint-type needle of 6.5 mm on a braided thread of 100% absorbable polyglycolic acid (PGA), violet in colour and with a 30 cm strand: the classic format for ophthalmic microsurgery and for the approximation of delicate soft tissues. Professional presentation in a box of 12 sterile units with batch traceability, ideal for supplier approval and public procurement tenders.
2. Technical Explanation
The thread is manufactured from polyglycolic acid (PGA), a synthetic linear-chain polyester that degrades by hydrolysis with predictable kinetics: mass absorption is complete between 60 and 90 days, while tensile strength is maintained above the critical healing phase (75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks). The polycaprolactone and calcium stearate coating reduces friction and the sawing effect on tissue, improves thread glide and facilitates knot seating with excellent knot security.
The Micropoint DSP 6.5 spatulated needle features a flat lateral cutting edge that separates and displaces the fibres of lamellar tissues (cornea, sclera, conjunctiva, fine skin) rather than cutting them, minimising trauma and the risk of leakage. The Prime finish (non-grooved surface) optimises passage through tissue. USP 7/0 gauge (metric 0.5) is the usual thickness for precision ophthalmic suture, and the violet colour ensures immediate visibility on the surgical field. Product sterile by ethylene oxide (EO), single-use, not re-sterilisable and conforming to USP/EP pharmacopoeias for sterile absorbable sutures.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the manufacturer/distributor (Cahnos S.L.).
3.1. General characteristics
| Parameter | Specification |
| Brand / quality | PREMISUT PRIME (premium range) |
| Thread material | Polyglycolic acid (PGA) 100 % synthetic |
| Structure | Braided multifilament, non-grooved surface |
| Coating | Polycaprolactone and calcium stearate |
| Absorption type | By hydrolysis; complete mass absorption in 60-90 days |
| Gauge / size | USP 7/0 (metric EP 0.5) |
| Needle shape | ⅜ circle (3/8 circular) |
| Tip type | Spatulated Micropoint Spatula (DSP 6.5 Prime profile) |
| Needle size | 6.5 mm |
| Swaged | Single needle (1 thread with needle) |
| Thread length | 30 cm |
| Thread colour | Violet |
| Sterilisation | Ethylene oxide (EO); single-use, not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmic surgery and microsurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for sterile absorbable sutures |
| Manufacturer reference | P114DSP6,570 |
| SKU Cahnos | AMP114DSP6,570 |
3.2. Tensile strength and absorption profile
| Period | Remaining tensile strength | Absorption |
| 2 weeks | Approximately 75 % | — |
| 3 weeks | Approximately 50 % | — |
| 4 weeks | Approximately 40 % | — |
| 60-90 days | — | Complete absorption by hydrolysis |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 8/0 | 0.4 | 0.040 – 0.049 mm |
| 7/0 (this product) | 0.5 | 0.050 – 0.069 mm |
| 6/0 | 0.7 | 0.070 – 0.099 mm |
| 5/0 | 1 | 0.10 – 0.149 mm |
4. Equivalences and Cross-References
The reference P114DSP6,570 corresponds to the official nomenclature of the PREMISUT PRIME range (DSP 6.5 profile: ⅜ circle spatulated Micropoint needle of 6.5 mm, USP 7/0 gauge, violet 30 cm thread, single-needle configuration) and Cahnos markets it without altering any characters: no digit may be added, removed or reordered when ordering or tendering.
Braided polyglycolic acid with a precision spatulated needle is one of the most standardised ophthalmic absorbable suture families on the market. There is no manufacturer-validated equivalence table cross-referencing this specific configuration (100% PGA, USP 7/0, 3/8 spatulated needle of 6.5 mm, single needle, 30 cm) with references from other manufacturers; the following rows are offered as a functional comparison verified against the manufacturer’s official catalogue or GUDID/FDA database and must be validated against the IFU before any substitution. As they are another brand, they do not constitute an exact reference equivalence (reserved for the same manufacturer).
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | COATED VICRYL® (polyglactin 910) – MICROPOINT Spatula, TG140-8 6.5 mm, 3/8 circle, 7-0, 30 cm, violet braided | J566G | Comparable by category (not interchangeable 1:1) | They match on the micropoint spatulated needle TG140-8 of 6.5 mm in 3/8 circle, USP 7/0 gauge, 30 cm length, violet colour and braided structure. They differ in material (polyglactin 910 / PGLA vs. 100% PGA), coating and configuration (double needle vs. single needle). Code confirmed in GUDID/FDA database and official Ethicon catalogue. |
| B. Braun (Aesculap) | SAFIL® Violet – 7/0 (0.5), 30 cm, double needle DLM6 6 mm, 3/8 circle micropoint lancet type | G1048712 | Comparable by category (not interchangeable 1:1) | They match on base material (pure polyglycolic acid), USP 7/0 gauge (EP 0.5), 30 cm length and violet colour. B. Braun does not use the term ‘spatula’: its functional equivalent is the 6 mm micropoint lancet needle (within ±0.5 mm tolerance over 6.5 mm). They differ in configuration (double needle vs. single needle), coating (glyconate vs. polycaprolactone/calcium stearate) and sterilisation. Code confirmed in GUDID/FDA database. |
| SMI (Steelco Medical Industries) | SURGICRYL® PGA Ophthalmic – side cutting spatula, 2×DSP 6.4 mm, 7/0, 45 cm, violet | OSU072 | Comparable by category (not interchangeable 1:1) | They match on material (braided polyglycolic acid coated with polycaprolactone and calcium stearate), USP 7/0 gauge, 6.4 mm side-cutting spatulated needle (within tolerance) and colour scheme. They differ in strand length (45 cm vs. 30 cm) and configuration (double needle vs. single needle). Code confirmed in official SMI datasheet. |
There is no manufacturer-validated equivalence table cross-referencing this specific configuration (100% PGA, 6.5 mm micropoint spatulated needle in ⅜ circle, USP 7/0 gauge, 30 cm strand, Prime quality, single needle) with references from other manufacturers; consult the technical department before use in tenders. Other homologous families of braided polyglycolic acid with spatulated needle — e.g. Dexon II / Safil Quick (rapid-release PGA), Novosyn (PGLA from B. Braun) or Polysorb (Lactomer) — must be reviewed property by property (material, coating, USP/metric gauge, curvature, needle point family, needle size and number, strand length, colour and CE/MDR regulatory classification) before any substitution. This needle geometry (DSP 6.5, USP 7/0, 30 cm, single needle) is only fully safely interchangeable within the PREMISUT system itself.
5. Selection tips and variants of interest
Tissue to suture: USP 7/0 gauge (metric EP 0.5, diameter 0.050-0.069 mm) is the microsurgery choice for very delicate planes: cornea, sclera and conjunctiva in ophthalmology, fine vascular approximation, closure of fine skin and low-tension soft tissues. The 6.5 mm micropoint spatulated needle in ⅜ circle is the best option for lamellar tissues, where it dissects the plane without cutting it and reduces the risk of leakage.
Single-needle configuration: this 30 cm reference with a single needle is the standard format for interrupted precision sutures. If your protocol prefers continuous suture without rethreading, the same family offers the double-needle version: PGA Prime 7/0 2×DSP 6.5 mm of 45 cm (SKU AMP111DSP6,570-2). For maximum fineness, the same DSP 6.5 needle in 8/0 gauge of 30 cm (SKU AMP114DSP6,580).
Material variants on the same needle: if an absorption profile with polyglactin kinetics is required (56-72 days instead of 60-90 days), the PREMISUT range of Polyglactin 910 offers the same spatulated assembly DSP 6.5 in 7/0 and 30 cm (SKU P1L14DSP6,570) and in double needle of 45 cm (SKU P1L11DSP6,570-2). Note that the polymer composition changes, so it is not interchangeable for indication purposes without clinical validation.
Sterility verification: sterile product by ethylene oxide and single-use; check the blister integrity and expiry date before each use, keep the reference P114DSP6,570 together with the batch number for traceability in the operating theatre and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.