Description
1. Product Presentation
The Premisult range multifilament PGA absorbable suture is the reference surgical closure solution for professionals who demand a synthetic resorbable thread with fully predictable behaviour, excellent handling and maximum knot security. Its ⅜ circle, cylindrical body and 64 mm blunt point needle (reference DRN 64) passes through tissues separating fibres without cutting them, minimising trauma and being especially suitable for soft tissue approximation, ligatures and general surgery. It is a synthetic absorbable, sterile, single-use medical device with an excellent quality-price ratio for B2B supply to hospitals, clinics, operating theatres and purchasing centres. It is supplied in a box of 12 units with a minimum order of 30 boxes, guaranteeing a continuous and traceable supply for your healthcare centre. Ref. AM113DRN6401.
2. Technical explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided and fluted multifilament structure, coated with polycaprolactone and calcium stearate. This configuration provides great flexibility, low shape memory and a low friction coefficient that favours thread sliding, handling and a firm, secure knot tying, with high initial tensile strength.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity and with minimal tissue reaction. The thread retains 75% of tensile strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks, an ideal profile for tissues requiring support during 2 to 4 weeks of healing.
The ⅜ circle needle with cylindrical body and 64 mm blunt point (atraumatic, blunt point) penetrates by separating fibres without cutting effect, reducing the risk of tearing, especially in friable tissues. The violet thread ensures optimal visibility on the surgical field. Sterilisation by ethylene oxide; sterile single-use product, not resterilisable.
3. Technical Specifications
| Characteristic | Specification |
| Reference (SKU) | AM113DRN6401 |
| Factory reference | 113DRN6401 |
| Range / quality | Premisult (standard quality) |
| Composition | 100% polyglycolic acid (PGA), coating of polycaprolactone and calcium stearate |
| Thread structure | Multifilament braided fluted |
| Colour | Violet |
| Gauge | USP 1 (metric 4) |
| Thread length | 90 cm |
| Needle shape | ⅜ circle |
| Needle body | Cylindrical |
| Tip type | Blunt point (atraumatic, blunt point) |
| Needle reference | DRN 64 |
| Needle size | 64 mm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60 – 90 days |
| Tensile retention | 75 % (2 weeks) / 50 % (3 weeks) / 40 % (4 weeks) |
| Sterilisation | Ethylene oxide (EO), single-use |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
Tensile strength retention profile:
| Period after implantation | Remaining tensile strength |
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Total absorption | 60 – 90 days by hydrolysis |
Excellent strength during the critical healing period, smooth passage through tissues, uniform and atraumatic surface, absolute knot security and comfortable handling, with minimal tissue reaction.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is the classic standard among medium-absorption synthetic multifilament absorbable sutures. The reference homologous families on the market are: Ethicon (Vicryl, in polyglactin 910), B. Braun (Safil and Surgicryl), Medtronic (Polysorb), SMI (Surgicryl PGA, with identical polymer, identical coating of polycaprolactone and calcium stearate, and 60-90 day absorption), Assut (Assucryl), DemeTECH (DemeSORB in PGA and DemeCRYL in polyglactin 910) and Dolphin Sutures (Petcryl).
These comparisons are offered at category level, not as exact reference equivalence: each manufacturer uses its own needle code and nomenclature, so before a formal substitution, the polymer and coating, USP gauge, armed (single needle), ⅜ curvature, point family (blunt), needle size (64 mm ± 1 mm) and thread length must be checked one by one. As a guide, in the SMI Surgicryl PGA standard range, the blunt body is limited to 1/2 circle conical needles (HR, up to 65 mm) without a blunt point in 3/8 of 64 mm, so the equivalence with this reference would be only functional category, not interchangeable. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
Select this suture when you need a medium-high gauge (USP 1) with high tension retention during the first weeks of healing and complete absorption between 60 and 90 days, especially indicated for tissues under tension, abdominal wall, plane approximation and ligatures. The blunt point is the most respectful of delicate tissues, as it separates fibres without cutting them.
If you need a different thread length, keep the same DRN 64 needle in 75 cm (ref. AM112DRN6401) or 100 cm (ref. AM117DRN6401). In Prime quality, the same configuration is available in 75, 90 and 100 cm (refs. AMP112DRN6401, AMP113DRN6401 and AMP117DRN6401). As a polyglactin 910 (PGLA) alternative with the same needle pattern, see references 1L12DRN6401, 1L13DRN6401 and 1L17DRN6401 (standard quality) and P1L12DRN6401, P1L13DRN6401 and P1L17DRN6401 (Prime quality). All references are supplied in a box of 12 units and the minimum order is 30 boxes. For special B2B conditions, volume orders, scheduled deliveries and formalised quotations, contact the commercial department of Cahnos.





Reviews