Description
1. Product Presentation
The PGA multifilament absorbable suture is the reference surgical closure solution for professionals who demand a synthetic absorbable thread with fully predictable behaviour, excellent handling and maximum security in knot tying. Its ⅜ circle needle, cylindrical body and blunt point of 64 mm (reference DRN 64) penetrates tissues separating the fibres without cutting them, minimising trauma and being especially suitable for tissue approximation, ligatures and general surgery.
It is a synthetic absorbable medical device, sterile and single-use, with an excellent price-quality ratio for B2B procurement for hospitals, clinics, operating theatres and purchasing centres. It is presented in a box of 12 units with a minimum order of 30 boxes, guaranteeing continuous and traceable supply for your healthcare centre. Ref. AM117DRN6401.
2. Technical explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided and grooved multifilament structure, coated with polycaprolactone and calcium stearate. This configuration provides great flexibility, low shape memory and a controlled friction coefficient that favours thread sliding, handling and firm, secure knot tying, with high initial tensile strength.
Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, without depending on the patient’s enzymatic activity and with minimal tissue reaction. The thread maintains 75% of tensile strength at 2 weeks, 50% at 3 and 40% at 4, an ideal profile for tissues requiring support during 2 to 4 weeks of healing.
The ⅜ circle needle with cylindrical body and blunt point (atraumatic, blunt point) of 64 mm penetrates separating the fibres without cutting effect, which reduces the risk of tearing, especially in friable tissues. The violet thread guarantees optimal visibility on the surgical field. Sterilisation by ethylene oxide; sterile single-use product, without possibility of re-sterilisation.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference (SKU) | AM117DRN6401 |
| Range / quality | Normal |
| Composition | 100% polyglycolic acid (PGA), coating of polycaprolactone and calcium stearate |
| Thread structure | Multifilament braided fluted |
| Colour | Violet (also available colourless depending on presentation) |
| Gauge | USP 1 (metric 4) |
| Thread length | 100 cm |
| Needle shape | ⅜ circle |
| Needle body | Cylindrical |
| Tip type | Blunt point (atraumatic, blunt point) |
| Needle reference | DRN 64 |
| Needle size | 64 mm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO), single-use |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
Tensile strength retention profile:
| Period after implantation | Remaining tensile strength |
|---|---|
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Total absorption | 60 – 90 days by hydrolysis |
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is the classic standard among synthetic absorbable multifilament sutures of medium absorption. The homologous reference families on the market are: Ethicon (Vicryl, in polyglactin 910), B. Braun (Safil and Surgicryl), Medtronic (Polysorb and Dexon II), SMI (Surgicryl PGA, with identical polymer, identical polycaprolactone and calcium stearate coating, and 60-90 day absorption), Assut (Assucryl), DemeTECH (DemeCRYL) and Dolphin Sutures (Petcryl).
These comparisons are offered at category level, not as exact reference equivalence: each commercial house uses its own needle code and nomenclature, so before a formal substitution, the polymer and coating, USP gauge, needle configuration (single needle), ⅜ curvature, point family (blunt), needle size (64 mm ± 1 mm) and thread length must be checked one by one. As a guide, in the standard SMI Surgicryl PGA range, the blunt point is limited to conical needles of 1/2 circle (HR, maximum 48-50 mm), so equivalence with this reference would only be functional by category, not interchangeable.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Within the Cahnos catalogue, the reference with identical configuration (DRN 64 needle, USP gauge 1, violet thread of 100 cm) in Prime quality is AMP117DRN6401, and as an alternative in polyglactin 910 (PGLA) with the same needle pattern, 1L17DRN6401 (normal quality) and P1L17DRN6401 (Prime quality) are available.
5. Selection tips and variants of interest
Select this suture when you need a medium-high gauge (USP 1) with high tension retention during the first weeks of healing and complete absorption between 60 and 90 days, especially indicated for tissues under tension, abdominal wall, approximation of planes and ligatures. The blunt point is the most respectful with delicate tissues, as it separates the fibres without cutting them.
If you need another thread length, keep the same DRN 64 needle in 75 cm (ref. AM112DRN6401) or 90 cm (ref. AM113DRN6401). In Prime quality, the same configuration is available in 75, 90 and 100 cm (refs. AMP112DRN6401, AMP113DRN6401 and AMP117DRN6401). As an alternative in polyglactin 910 with the same needle pattern, see references 1L12DRN6401, 1L13DRN6401 and 1L17DRN6401 (normal quality) and P1L12DRN6401, P1L13DRN6401 and P1L17DRN6401 (Prime quality). For purchasing centres, a minimum order of 30 boxes applies; contact the commercial department of Cahnos for institutional conditions, scheduled deliveries and formalised budgets.





Reviews