Description
1. Product Presentation
The absorbable multifilament PGA Prime suture is the reference surgical closure solution for the surgical block that requires a synthetic absorbable thread with fully predictable behaviour, excellent handling and maximum security in knot tying. Its ⅜ circle needle, cylindrical body and blunt point of 64 mm (reference DRN 64) penetrates tissues separating the fibres without cutting them, minimising trauma and being especially suitable for tissue approximation, ligatures and general surgery.
It is a synthetic absorbable medical device, sterile and single-use, with an excellent quality-price ratio for B2B supply to hospitals, clinics, operating theatres and purchasing centres. It is presented in a box of 12 units with a minimum order of 30 boxes, guaranteeing continuous and traceable supply for your healthcare centre. Ref. AMP113DRN6401.
2. Technical explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided and grooved multifilament structure, coated with polycaprolactone and calcium stearate. This configuration provides great flexibility, low shape memory and a contained friction coefficient that favours thread sliding, handling and firm, secure knot tying, with high initial tensile strength.
Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity and with minimal tissue reaction. The thread maintains 75% of tensile strength at 2 weeks, 50% at 3 and 40% at 4, while the tissue recovers its own resistance; an ideal profile for tissues requiring support during 2 to 4 weeks of healing.
The ⅜ circle needle with cylindrical body and blunt (atraumatic) point of 64 mm penetrates separating the fibres without cutting effect, reducing the risk of tearing, especially in friable tissues. The violet thread guarantees optimal visibility on the surgical field. Sterilisation by ethylene oxide; sterile single-use product, with no possibility of re-sterilisation.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference (SKU) | AMP113DRN6401 |
| Range / quality | PGA Prime |
| Composition | 100% polyglycolic acid (PGA), coating of polycaprolactone and calcium stearate |
| Thread structure | Multifilament braided fluted |
| Colour | Violet |
| Gauge | USP 1 (metric 4) |
| Thread length | 90 cm |
| Needle shape | ⅜ circle |
| Needle body | Cylindrical |
| Tip type | Blunt point (atraumatic) |
| Needle reference | DRN 64 |
| Needle size | 64 mm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO), single-use |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
Tensile strength retention profile:
| Period after implantation | Remaining tensile strength |
|---|---|
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Total absorption | 60 – 90 days by hydrolysis |
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is the classic standard among synthetic absorbable multifilament sutures of medium absorption. The homologous reference families on the market are: Ethicon (Vicryl, in polyglactin 910), B. Braun (Safil and Surgicryl), Medtronic (Polysorb and Dexon II), SMI (Surgicryl PGA, with identical polymer, identical polycaprolactone and calcium stearate coating, and absorption of 60-90 days), Assut (Assucryl), DemeTECH (DemeCRYL) and Dolphin Sutures (Petcryl).
There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering. The configuration of this article (PGA multifilament, ⅜ circle needle, cylindrical body, blunt point of 64 mm, USP gauge 1 and 90 cm thread) does not coincide in a verifiable 1:1 manner with any published reference from another manufacturer in official or verifiable catalogue sources. For guidance: in the standard SMI Surgicryl PGA range, the blunt body is limited to conical 1/2 circle needles (HR, maximum 48-50 mm), so the equivalence with this reference would only be functional by category, not interchangeable. Before a formal substitution, the following must be checked one by one: polymer and coating, USP gauge, assembly (single needle), ⅜ curvature, point family (blunt), needle measurement (64 mm ± 1 mm) and thread length.
5. Selection tips and variants of interest
Select this suture when you need a medium-high gauge (USP 1) with high tension retention during the first weeks of healing and complete absorption between 60 and 90 days, especially indicated for tissues under traction, abdominal wall, approximation of planes and ligatures. The blunt point is the most respectful of delicate tissues, as it separates the fibres without cutting them.
If you need another thread length, keep the same DRN 64 needle in 75 cm (ref. AMP112DRN6401) or 100 cm (ref. AMP117DRN6401). In normal quality, the same configuration is available with reference AM113DRN6401. As a polyglactin 910 alternative with the same needle pattern, see references 1L13DRN6401 (normal quality) and P1L13DRN6401 (Prime quality). For purchasing centres, a minimum order of 30 boxes applies; contact the commercial department of Cahnos for institutional conditions, scheduled deliveries and formalised budgets.