We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture (Polyglycolic Acid) | ½ Circle Cylindrical Body Trocar Point Tapercut Needle HRT 40 mm | USP 2/0 (Metric 3) Gauge | Violet Fluted Thread 90 cm | Ref. 113HRT4020 | Box of 12 units

Original price was: 34,90 €.Current price is: 26,10 €.

Synthetic absorbable suture of 100% polyglycolic acid (PGA), braided and coated multifilament, from the Premisut range, mounted with a ½-circle needle with cylindrical body and trocar point (Tapercut), 40 mm (HRT 40), USP 2/0 (metric 3) gauge and 90 cm violet fluted thread. Predictable absorption by hydrolysis in 60–90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterilised by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and general surgery. Manufacturer reference 113HRT4020 · SKU AM113HRT4020, presentation in a box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM113HRT4020

Description

1. Commercial Introduction

The absorbable multifilament suture made of polyglycolic acid (PGA), reference 113HRT4020 (SKU AM113HRT4020), is the reference surgical closure solution for hospitals, private operating theatres, clinics and purchasing centres looking for a reliable, predictable synthetic absorbable thread with an excellent price-quality ratio in B2B procurement and tenders. Its ½ circle trocar-point needle of 40 mm penetrates firm tissues with controlled trauma, while the 90 cm violet grooved thread ensures optimal visibility of the surgical field and excellent handling at every stitch. It is a synthetic, absorbable medical device, sterile by ethylene oxide and single-use, presented in a box of 12 units in individual sachets with batch traceability.

2. Technical Explanation

Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a grooved finish. Its coating of polycaprolactone and calcium stearate improves the thread’s sliding through tissue, reduces friction and the sawing effect, and facilitates firm, secure knot tying. Absorption occurs by hydrolysis, i.e., by controlled degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, metabolised by the body with minimal tissue reaction.

The ½ circle needle (approx. 180°) with cylindrical body and trocar point (Tapercut profile) combines a rounded body that passes through tissue separating the fibres with minimal injury and a contained cutting tip that allows penetration of fibrous and non-compliant tissues — fascia, aponeurosis, muscular planes — with less effort and control. The ½ curvature facilitates work in deep planes and closed surgical fields, and the violet colour improves thread visibility throughout the procedure.

3. Technical Specifications

3.1. Technical data sheet for reference 113HRT4020

Parameter Specification
Factory reference 113HRT4020
Reference (SKU) AM113HRT4020
Range / Quality PREMISUT – Normal quality
Composition 100% synthetic absorbable polyglycolic acid (PGA)
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 2/0 (metric 3 – EP)
Thread colour Violet grooved
Thread length 90 cm
Needle shape ½ circle (approx. 180°)
Needle body Cylindrical
Needle tip Trocar (Tapercut)
Needle size HRT 40 (40 mm), 1 needle per thread
Absorption mechanism Hydrolysis (60–90 days)
Sterilisation Ethylene oxide (EO); single-use, non-reesterilizable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (individual sterile sachets)
Minimum order 30 boxes
Regulatory standard Conforms to USP/EP Pharmacopoeia for synthetic absorbable sutures

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75%
3 weeks 50%
4 weeks 40%
Complete absorption 60–90 days (by hydrolysis)

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Sterile by ethylene oxide. Price per box of 12 units.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia

USP size Metric measurement (EP) Approximate thread diameter
2/0 (this product) 3 0.30 – 0.349 mm
0 3.5 0.35 – 0.399 mm
1 4 0.40 – 0.499 mm

The thread diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without exceeding their limits.

4. Equivalences and Cross-References

Polyglycolic acid (PGA) is the most widely used medium-duration braided multifilament absorbable on the market. This reference shares the absorption profile (60–90 days), braided structure coated with polycaprolactone and calcium stearate, USP 2/0 gauge, ½ circle HRT 40 mm trocar-point needle and 90 cm length with the main homologous families of braided absorbable suture: SMI Surgicryl® PGA (pure violet braided polyglycolic acid), B. Braun Safil® (pure coated braided polyglycolic acid) and, at category level, the polyglactin 910 copolymer ranges such as Ethicon Vicryl® / Vicryl® Plus, Medtronic Polysorb® or Assut Assucryl® 910.

The comparison with polyglactin 910-type copolymers is made at category level and is not interchangeable 1:1: they coincide in needle geometry, gauge and handling, but the polymer differs (90/10 glycolide/L-lactide copolymer versus PGA homopolymer) and the declared absorption profile (56–72 days in PGLA versus 60–90 days in PGA). No confirmed external reference code has been found in official sources for the exact configuration USP 2/0 / trocar-point HRT 40 mm needle / 90 cm thread / violet in other commercial houses; specific codes must be confirmed with each manufacturer. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.

Within the Cahnos catalogue, the most direct alternatives by needle configuration and gauge are: 1L13HRT4020 (polyglactin 910 USP 2/0, same HRT 40 mm needle, violet, 90 cm, absorption 56–72 days), AM113HRT4010 (PGA USP 0, same HRT 40 mm needle, violet, 90 cm), AMP113HRT4010 (PGA Prime USP 0, same configuration, superior quality) and AM113HRT4820 (PGA USP 2/0, HRT 48 mm trocar needle, violet, 90 cm, longer needle).

5. Selection tips and variants of interest

The USP 2/0 gauge (metric 3) is very versatile: suitable for subcutaneous tissue, superficial muscular planes, approximation of soft tissues and closures that require a balance between initial strength and delicacy during a healing period of 2 to 4 weeks. The trocar point (Tapercut) is recommended for firm and dense tissues (fascia, aponeurosis); if the tissue is soft or friable, consider the conical point variant (HR, ref. AM113HR4020); if maximum atraumaticity is sought, the blunt point (HRN, ref. AM113HRN4010H); and for very firm tissues with clean cutting, the reverse cutting triangular point (HS). The violet grooved thread offers maximum visibility over the surgical field.

Reference (SKU) Variant of interest
AM113HRT4020 PGA USP 2/0, HRT 40 mm trocar needle, violet, 90 cm (current product)
1L13HRT4020 PGLA 910 USP 2/0, same HRT 40 mm needle, violet, 90 cm (absorption 56–72 days)
AM113HRT4010 PGA USP 0, same HRT 40 mm needle, violet, 90 cm (larger gauge)
AM113HRT4820 PGA USP 2/0, HRT 48 mm trocar needle, violet, 90 cm (longer needle)
AM113HR4020 PGA USP 2/0, HR 40 mm conical needle, violet, 75 cm (soft tissues)
AM113HRN4010H PGA USP 0, blunt point HRN 40 Heavy needle, violet, 90 cm (maximum atraumaticity)

All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or confirmation of equivalences for tenders, contact our technical-commercial team.

Additional information

Material

100% polyglycolic acid (PGA) multifilament braided

Coating

Polycaprolactone and calcium stearate

USP size

2/0 (metric 3)

Needle shape

½ circle (approx. 180°)

Needle body

Cylindrical

Needle size

HRT 40 mm (1 needle per thread)

Colour

Violet grooved

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units (individual sterile sachets)

Minimum order

30 boxes

Manufacturer reference

113HRT4020

Medida de aguja

HRT 40

Usp

2/0

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture (Polyglycolic Acid) | ½ Circle Cylindrical Body Trocar Point Tapercut Needle HRT 40 mm | USP 2/0 (Metric 3) Gauge | Violet Fluted Thread 90 cm | Ref. 113HRT4020 | Box of 12 units”

Your email address will not be published. Required fields are marked *