We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Prime Suture | ½ Circle Cylindrical Trocar Point (Tapercut) Needle HRT 36 mm | USP 1 Gauge | Violet Thread 90 cm | Box of 12 units Ref. AMP113HRT3601

Original price was: 44,90 €.Current price is: 32,60 €.

Absorbable multifilament suture of 100% polyglycolic acid (PGA) in Prime quality, USP 1 gauge (metric 4), mounted on a ½ circle cylindrical body needle with trocar point (tapercut) of 36 mm (HRT36) and a 90 cm grooved violet thread. Predictable absorption by hydrolysis between 60 and 90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Coated with polycaprolactone and calcium stearate for smooth passage and secure knotting; sterile by ethylene oxide, single-use and with minimal tissue reaction. Ideal for tissue approximation, ligatures and general surgery. Price per box of 12 units; minimum order of 30 boxes. Ref. AMP113HRT3601.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP113HRT3601

Description

1. Commercial Introduction

The Absorbable Multifilament PGA Prime Suture, reference AMP113HRT3601, is the surgical closure solution your centre needs for general surgery, gynaecology and urology procedures that require controlled reabsorption, excellent handling and impeccable knot security. It combines a ½ circle needle with a cylindrical body and trocar point (tapercut) of 36 mm with a braided thread of 100% polyglycolic acid (PGA) in USP 1 gauge, violet fluted colour and 90 cm length.

Presented in B2B format in a box of 12 units with a minimum order of 30 boxes, it offers an outstanding price-quality ratio for operating theatres, clinics, distributors, purchasing centres and tenders for surgical material.

2. Technical Explanation

Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer that is presented in a braided multifilament structure with a fluted finish, coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves thread glide and facilitates firm, secure knotting, with minimal tissue reaction.

Absorption occurs by hydrolysis, a predictable process independent of the patient’s enzymatic activity, completed within 60 to 90 days. Tensile strength retention maintains the necessary support during the first 2 to 4 weeks of healing (75% at 2 weeks, 50% at 3 and 40% at 4), while the tissue regains its own strength.

The HRT36 needle features a ½ circle curvature with a cylindrical body and trocar point (tapercut): a convergent triangular-section point that combines firm penetration in moderate-to-high tension tissues with contained trauma. Its 36 mm length makes it suitable for deeper planes. The violet colour of the thread ensures optimal visibility on the surgical field. Product sterilised by ethylene oxide, single-use and not re-sterilisable.

3. Technical Specifications

3.1. Technical data sheet for reference AMP113HRT3601

Characteristic Specification
Reference (SKU) AMP113HRT3601 (manufacturer ref. P113HRT3601)
Range / Quality Premisut – Prime
Material 100 % Polyglycolic acid (PGA), absorbable homopolymer
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge / size USP 1 (metric 4), conforming to USP/EP Pharmacopoeia
Thread colour Violet grooved
Thread length 90 cm
Needle shape ½ circle (1/2 circular)
Needle body Cylindrical
Needle tip Tapercut (converging triangular cross-section)
Needle size HRT 36 mm, 1 needle per thread
Absorption mechanism Hydrolysis, completed between 60 and 90 days
Sterilisation Ethylene oxide (EtO); sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Commercial presentation Box of 12 units; minimum order of 30 boxes

3.2. Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Total absorption 60-90 days, by hydrolysis

3.3. Size equivalence

USP size Metric size Approximate diameter
1 4 0.40 – 0.499 mm (indicative according to Pharmacopoeia)

3.4. Reference code decoding

Official reference P113HRT3601: 113 (90 cm violet thread) + HRT36 (½ circle needle with cylindrical body and trocar point of 36 mm) + 01 (USP 1 gauge). The reference is marketed without altering characters: no digit may be added, removed or reordered when ordering or tendering.

4. Equivalences and Cross-References

Polyglycolic acid (PGA) with 60-90 days of absorption is one of the most well-established synthetic absorbable multifilament suture raw materials on the market. There is no official equivalence table validated by the manufacturer for a 1:1 cross-reference with the exact configuration of this reference (HRT 36 mm needle, USP 1 gauge, 90 cm violet thread); therefore, the codes cited below correspond to catalogue comparisons verified against authorised distribution and are not interchangeable 1:1.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) Coated VICRYL® Plus Antibacterial – braided polyglactin 910 with triclosan, violet, USP 1, 90 cm, 36 mm tapercut needle, ½ circle VCP519H Comparable by category (not interchangeable 1:1) Confirmed in authorised distribution: USP 1 gauge, violet colour, 90 cm length, ½ circle shape, 36 mm needle size and tapercut point family all match; the polymer differs (polyglactin 910 with triclosan versus 100% PGA) and the presentation (box of 36 units versus 12 units).
Ethicon (Johnson & Johnson MedTech) Coated VICRYL® – braided coated polyglactin 910, violet, USP 1, 90 cm, CT-1 needle of 36 mm, ½ circle, taper point J347H Comparable by category (not interchangeable 1:1) USP 1 gauge, colour, 90 cm length, ½ circle shape and 36 mm needle size match; the point differs (atraumatic CT-1 taper versus reinforced-penetration trocar tapercut) and the polymer (polyglactin 910 versus 100% PGA).

There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering. As equivalent market families to verify reference by reference in their official data sheet before substitution, the following lines are cited: 100% PGA braided coated —Safil (B. Braun), Dexon II (Medtronic/Covidien), Surgicryl PGA (SMI)— and polyglactin 910 —Vicryl / Vicryl Plus (Ethicon), Polysorb (Medtronic), Novosyn (B. Braun)—, always checking USP 1 gauge, 36 mm needle size in ½ circle, trocar point, 90 cm thread length and violet colour. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.

5. Selection tips and variants of interest

USP 1 gauge (metric 4) is indicated for tissues that withstand moderate-to-high tension: fascia, aponeurosis, muscle planes, abdominal wall and ligation of medium-calibre vessels. The HRT ½ circle trocar point (tapercut) needle is the appropriate choice for firm tissues requiring clean, tear-free penetration; if you need a fully atraumatic point for soft tissues, consider the conical point (HR) versions of the same PGA family.

Reference Variant
AMP113HRT3601 PGA Prime USP 1, HRT36 trocar point needle, violet, 90 cm (current product)
AMP123HRT3601 PGA Prime USP 1, HRT36 trocar point needle, colourless, 90 cm (same configuration in colourless)
AMP113HRT3610 PGA Prime USP 0, HRT36 trocar point needle, violet, 90 cm (smaller gauge)
AMP113HRT3620 PGA Prime USP 2/0, HRT36 trocar point needle, violet, 90 cm (smaller gauge)
AMP113HRT3630 PGA Prime USP 3/0, HRT36 trocar point needle, violet, 90 cm (fine gauge)
AMP113HR3601 PGA Prime USP 1, HR36 conical point needle, violet, 90 cm (atraumatic point)
AMP113HRN3601H PGA Prime Heavy USP 1, HRN36 blunt point needle, violet, 90 cm (maximum atraumatic in friable tissues)
AM113HRT3601 PGA standard quality USP 1, HRT36 trocar point needle, violet, 90 cm (standard range)
P1L13HRT3601 PGLA Prime USP 1, HRT36 trocar point needle, violet, 90 cm (absorption 56-72 days)
P1L23HRT3601 PGLA Prime USP 1, HRT36 trocar point needle, colourless, 90 cm (colourless PGLA version)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. If you require a longer strength retention (180-210 days), consider the polydioxanone (PDO) family. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, and keep the reference together with the batch number for traceability in the operating theatre. For B2B volume conditions or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

100% Polyglycolic acid (PGA), polycaprolactone and calcium stearate coating

Thread structure

Multifilament braided fluted

Gauge

USP 1 (metric 4)

Needle shape

1/2 circle, cylindrical body

Needle size

HRT 36 mm, 1 needle per thread

Colour

Violet grooved

Strength retention

75% at 2 weeks; 50% at 3 weeks; 40% at 4 weeks

Sterilisation

Ethylene oxide (EtO), single-use, not re-sterilisable

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Manufacturer reference

P113HRT3601

Quality range

Premisut – Prime

Medida de aguja

HRT 36

Usp

1

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Prime Suture | ½ Circle Cylindrical Trocar Point (Tapercut) Needle HRT 36 mm | USP 1 Gauge | Violet Thread 90 cm | Box of 12 units Ref. AMP113HRT3601”

Your email address will not be published. Required fields are marked *