Description
1. Commercial Introduction
The Absorbable Multifilament PGA Prime Suture, reference AMP113HRT4820, is the reference choice in the operating theatre for hospitals, private clinics, purchasing groups and wholesalers seeking a high-performance absorbable synthetic thread with excellent value for money in B2B procurement and tenders. It features a ½ circle needle with cylindrical body and trocar point (tapercut) of 48 mm (HRT 48 Prime), USP gauge 2/0 and a 90 cm violet fluted thread, ensuring precision, handling and fully predictable absorption during the first weeks of healing.
Each unit is supplied sterile by ethylene oxide and ready to use, in individual pouches with batch traceability, with the highest quality of the Prime range and the guarantee of professional distribution from Cahnos.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, reduces the sawing effect, offers very smooth handling and guarantees firm and secure knot tying.
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance that the body metabolises without generating significant tissue reaction. The tensile strength retention profile maintains the necessary support during the critical healing phase while the tissue recovers its own resistance.
The ½ circle needle with cylindrical body and trocar point (tapercut profile) combines a rounded body that passes through tissue with minimal damage and a cutting point that allows penetration of fibrous and dense tissues, such as fascia, aponeurosis or muscle planes, with less effort and without enlarging the exit orifice. The violet colour ensures optimal visibility on the surgical field. Sterile single-use product, with no possibility of re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AMP113HRT4820
| Parameter | Specification |
|---|---|
| Reference (SKU Cahnos) | AMP113HRT4820 |
| Range / Quality | Prime (premium range) |
| Thread material | 100% polyglycolic acid (PGA), synthetic absorbable |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 2/0 (metric 3 – EP) |
| Thread colour | Violet (high visibility) |
| Thread length | 90 cm |
| Needle shape | ½ circle (approx. 180°) |
| Needle body | Cylindrical |
| Needle tip | Trocar (tapercut) |
| Needle size | 48 mm (HRT 48 Prime), 1 needle per thread |
| Absorption mechanism | By hydrolysis |
| Absorption period | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO); single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 sterile units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
|---|---|
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Complete absorption | 60 – 90 days by hydrolysis |
Predictable absorption by hydrolysis with minimal tissue reaction, excellent tensile strength and optimal knot tying, in accordance with USP / European Pharmacopoeia for synthetic absorbable sutures.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 2/0 (this product) | 3 | 0.30 – 0.349 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
4. Equivalences and Cross-References
The coated braided multifilament polyglycolic acid (PGA) with medium absorption (60–90 days) is one of the most widely used synthetic absorbables in general surgery and ligatures. The configuration of this data sheet —PGA homopolymer, ½ circle HRT 48 mm needle with trocar point (tapercut), USP gauge 2/0, 90 cm violet thread— has been compared with the main homologous families on the market:
- SMI Surgicryl® PGA: homologous family of braided PGA coated with polycaprolactone and calcium stearate, with comparable clinical behaviour; comparable at category level, not interchangeable 1:1 without verification of the specific code in the official catalogue.
- B. Braun / Aesculap Safil®: line of coated braided PGA with a range of ½ circle needles; the coating differs (glyconate versus polycaprolactone and calcium stearate), so it is not interchangeable 1:1.
- Ethicon / J&J MedTech Coated VICRYL® (polyglactin 910): copolymer range with a shorter absorption profile (56–72 days) and different chemistry from PGA homopolymer; comparable by category, not interchangeable 1:1.
- Medtronic Polysorb® and DemeTECH DemeSORB® PGA: absorbable braided ranges; confirm the exact polymer, point, gauge and geometry before any substitution in a tender.
There is no equivalence table validated by the manufacturer that cross-references this specific reference (PGA Prime USP 2/0, ½ circle HRT 48 mm needle with trocar point, 90 cm violet thread) with closed codes from other brands; consult the technical department before using in a tender. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (48 mm), ½ curvature, point family (trocar/tapercut), thread length (90 cm) and colour. The brands cited belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
USP gauge 2/0 (metric 3) offers an optimal balance between initial strength and delicacy for fine tissue planes, approximation of soft tissues, ligatures and general surgery with healing of 2 to 4 weeks. The ½ circle needle with trocar point (tapercut) is recommended for firm and dense tissues (fascia, aponeurosis, muscle planes); for soft or friable tissues consider the conical point (HR), and for very firm tissues with clean cutting, the reverse cutting triangular point (HS). The 90 cm fluted violet thread offers maximum visibility and sufficient strand for medium-length continuous sutures and multiple ligatures.
| Reference (SKU) | Variant of interest |
|---|---|
| AMP113HRT4820 | PGA Prime USP 2/0, ½ circle trocar needle HRT 48 mm, violet, 90 cm (current product) |
| AMP113HRT4020 | PGA Prime USP 2/0, ½ circle trocar needle HRT 40 mm, violet, 90 cm (shorter needle) |
| AMP113HRT4802 | PGA Prime USP 2, same HRT 48 mm trocar needle, violet, 90 cm (larger gauge) |
| AM113HRT4820 | PGA Normal quality USP 2/0, same HRT 48 mm trocar needle, violet, 90 cm (standard range) |
| P1L13HRT4820 | PGLA (polyglactin 910) Prime USP 2/0, HRT 48 mm trocar needle, violet, 90 cm (absorption 56–72 days) |
| AMP118HRT4810 | PGA Prime USP 0, ½ circle trocar needle HRT 48 mm, violet, 70 cm (higher strength and short strand) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or to enquire about additional gauges, lengths and colours, contact our technical-commercial team.





Reviews
There are no reviews yet.