Description
1. Product Presentation
The absorbable multifilament suture of polyglycolic acid (PGA) from the Premisut range is the reference synthetic reabsorbable solution for the professional who demands predictable behaviour, excellent tensile strength and great security in knot tying. This presentation incorporates a ½ circle needle with cylindrical body and Taperpoint conical point of 17 mm (HR17), USP 6/0 gauge (metric 0.7) and a 70 cm braided violet fluted thread.
It is the ideal choice for the approximation of soft tissues, ligatures, general surgery and ophthalmic surgery, in a professional format of a box of 12 units, ideal for stock management in operating theatres, clinics and purchasing centres, with special B2B conditions for hospitals and volume buyers (minimum order of 30 boxes). Price per box.
2. Technical explanation of the material and procedure
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure and coated with polycaprolactone and calcium stearate. This configuration gives the thread a regular (fluted) surface that favours sliding through tissue, smooth handling, low memory and firm, secure knot tying, even in fine gauges such as USP 6/0.
Its absorption occurs by hydrolysis, a uniform process independent of the patient’s enzymatic activity, with total absorption between 60 and 90 days: during the first weeks of healing the thread retains the necessary tensile strength (75% at 2 weeks, 50% at 3 and 40% at 4), just enough time for the tissue to recover its own strength.
The ½ circle needle with cylindrical body and conical point (Taperpoint geometry) of 17 mm separates the fibres without cutting effect: it is the most atraumatic configuration for delicate and friable tissues, with controlled passage and minimal injury along the penetration path. The fluted violet colour guarantees optimal visibility on the surgical field, highly valued in deep planes and in microsurgery. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AM118HR1760
| Parameter | Specification |
| Reference (SKU) | AM118HR1760 |
| Factory reference | 118HR1760 |
| Brand / Range | Premisut – Standard quality |
| Suture type | Synthetic absorbable braided multifilament |
| Material | 100 % absorbable polyglycolic acid (PGA) |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament, grooved surface |
| USP / metric gauge | 6/0 (metric 0.7) |
| Thread diameter | 0.070 – 0.099 mm (USP/EP standard) |
| Thread colour | Braided violet (also available undyed) |
| Thread length | 70 cm |
| Swaged | Single needle (1xHR17) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | 17 mm (HR17) |
| Absorption mechanism | Hydrolysis |
| Total absorption | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Regulatory standard | USP/EP |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis |
3.3. Size equivalence
| USP size | Approximate diameter (USP/EP standard) | Metric size |
| 6/0 | 0.070 – 0.099 mm | 0.7 |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
4. Equivalences and Cross-References
Braided coated polyglycolic acid is the most proven absorbable multifilament raw material of medium absorption in surgical practice (classic family like ‘Dexon’). This Premisut reference, with hydrolysis absorption of 60–90 days, tensile strength retention of 75/50/40% at 2/3/4 weeks and a single 17 mm cylindrical Taperpoint needle, is comparable at category level (not interchangeable 1:1) with the homologous PGA lines on the market verified against official sources: B. Braun Safil® (braided coated PGA range, violet), SMI Surgicryl® PGA, DemeTECH DemeSORB® PGA, Assut AssuCryl® PGA and the historical Medtronic Dexon® / Dexon II® range. However, no specific assembly code of single needle HR17 + USP 6/0 + 70 cm thread has been confirmed in public sources for these particular houses, so it cannot be tabulated as a closed reference.
There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. The polyglactin 910 lines (Ethicon Vicryl®, Medtronic Polysorb®, Safil® Quick in its PGLA variant, SMI Surgicryl® 910, Assut AssuCryl® 910) share the needle geometry and multifilament behaviour, but use a different copolymer (glycolide/L-lactide) with absorption of 56–72 days: they are comparable by category, not interchangeable 1:1 material to material. Any substitution must be validated code by code, verifying material, gauge, needle geometry (shape, body, point and size), assembly, thread length and presentation in the technical data sheet or IFU of each manufacturer.
5. Selection tips and variants of interest
The USP 6/0 gauge (metric 0.7) is the finest in the HR17 needle range, indicated for very delicate and low-tension tissues: mucosa, subcutaneous tissue, superficial planes and precision approximations, with special application in ophthalmic surgery, where aesthetic healing and minimal trauma are sought. The ½ circle conical point needle of 17 mm is the most atraumatic option for these tissues.
Variants and alternatives from the same Cahnos catalogue: AMP118HR1760 (same HR17 configuration, USP 6/0, violet, 70 cm in Prime quality, for high-demand protocols); 1L18HR1760 and P1L18HR1760 (same needle geometry and gauge in polyglactin 910 PGLA, with absorption of 56–72 days, to compare materials and unify stocks); AM118HR1730-2 (double needle 2xHR17 in USP 3/0 gauge for continuous sutures with bidirectional anchoring); AM118HR1330 / AM118HR1340 (short HR13 needle in USP 3/0 and 4/0 gauges, violet, 70 cm) and AM112HR1730 (HR17 needle, 3/0 gauge, 75 cm thread).
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply to the healthcare centre. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, institutional rates or equivalences from other commercial houses, contact our technical-commercial team.