Description
1. Commercial Introduction
The absorbable multifilament suture of polyglycolic acid (PGA) in Prime quality is the reference surgical closure solution for operating theatres, private clinics and purchasing groups that demand completely predictable behaviour, excellent tensile strength and great knot security. This presentation features a ½ circle, cylindrical body and taper point Taperpoint needle of 45 mm (HR45), USP 1 gauge and fluted violet thread of 70 cm.
It is supplied sterile and ready to use, in a box of 12 units with batch traceability, in B2B format aimed at hospital replenishment, tenders and public procurement. Reference AMP118HR4501.
2. Technical explanation of the material and procedure
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided and fluted multifilament structure, coated with polycaprolactone and calcium stearate. This configuration provides great flexibility, low shape memory and a low friction coefficient, which favours thread sliding through tissue, very smooth handling and a firm, secure knot.
Absorption occurs by hydrolysis, a uniform mechanism independent of the patient’s enzymatic activity, with total absorption between 60 and 90 days and minimal tissue reaction. During the first weeks of healing the thread maintains the necessary tensile strength while the tissue recovers its own resistance.
The ½ circle needle with cylindrical body and taper point (Taperpoint geometry) of 45 mm separates the fibres without cutting effect: it is the most atraumatic configuration for soft and friable tissues, with controlled passage and minimal injury along the penetration path. The fluted violet colour guarantees optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AMP118HR4501
| Characteristic | Specification |
| Reference (SKU) | AMP118HR4501 |
| Range / quality | PGA Prime |
| Suture type | Absorbable synthetic multifilament |
| Composition | 100 % polyglycolic acid (PGA) |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament, grooved |
| Gauge | USP 1 (metric 4) |
| Thread colour | Violet grooved |
| Thread length | 70 cm (1 thread) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical Taperpoint, atraumatic |
| Needle size | 45 mm (HR45), 1 needle per thread |
| Absorption mechanism | Hydrolysis |
| Total absorption | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Regulatory standard | USP / European Pharmacopoeia (EP) |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a completely predictable absorption rate. Indicated for tissue approximation, ligatures and general surgery.
4. Equivalences and Cross-References
Coated braided polyglycolic acid (PGA) is the most proven absorbable multifilament medium-absorption raw material in surgical practice (classic ‘Dexon’ family). This Prime reference, with hydrolysis absorption of 60–90 days and tensile strength retention of 75/50/40% at 2/3/4 weeks, shares polymer, coating (polycaprolactone and calcium stearate) and clinical profile with the homologous PGA lines on the market: B. Braun Safil® (coated braided PGA), SMI Surgicryl® PGA, DemeTECH DemeSORB® PGA, Assut AssuCryl® PGA and the historic range Medtronic Dexon®/Dexon II®. The polyglactin 910 (PGLA) ranges, such as Ethicon Vicryl® or Medtronic Polysorb®, share the absorbable multifilament category but differ in chemical composition and absorption profile (56–72 days).
There is no equivalence table validated by the manufacturer for this specific configuration (multifilament PGA Prime, ½ circle taper point Taperpoint HR45 needle of 45 mm, USP 1 gauge, violet thread of 70 cm) against the commercial houses cited; consult with the technical department before using in a tender. Before substituting this reference in a specification, check one by one: material, USP gauge, needle measurement (45 mm), curvature ½, point family (taper point), mounting (single needle), thread length (70 cm) and colour.
5. Selection tips and variants of interest
USP 1 gauge (metric 4) is indicated for tissues requiring high initial resistance: aponeurosis, fascia, muscular planes and high-tension closures. The taper point Taperpoint needle separates the fibres without cutting them, being the most atraumatic option for soft and friable tissues; if the plane to be sutured is firm and non-compliant, consider trocar or reverse cutting points from the same range.
| Reference | Variant |
| AMP118HR4501 | PGA Prime USP 1, HR 45 mm needle, violet, 70 cm (current product) |
| AM118HR4501 | PGA standard quality, USP 1, HR 45 mm needle, violet, 70 cm (cost optimisation) |
| AMP118HR4502 | PGA Prime USP 2, HR 45 mm needle, violet, 70 cm (larger gauge) |
| AMP113HR4501 | PGA Prime USP 1, HR 45 mm needle, violet, 90 cm (longer thread) |
| AMP118HR4001 | PGA Prime USP 1, HR 40 mm needle, violet, 70 cm (shorter needle) |
| AMP118HR4801 | PGA Prime USP 1, HR 48 mm needle, violet, 70 cm (longer needle) |
| P1L18HR4501 | PGLA Prime USP 1, HR 45 mm needle, violet, 70 cm (polyglactin 910, absorption 56-72 days) |
| AMP112HR4501H | PGA Prime Heavy USP 1, HR 45 mm taper needle, violet, 75 cm |
All references are supplied in a box of 12 units; the minimum order is 30 boxes. If you need longer strength retention, consider the polydioxanone (PDO) family, with absorption from 180 to 210 days. As it is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and keep the reference and batch for traceability in the operating theatre. For special B2B conditions by volume, hospital supply contracts or equivalences from other manufacturers, contact our technical-commercial team.





Reviews