Description
1. Commercial Introduction
The Absorbable Multifilament PGA Prime Suture, reference AMP113HR4801 (factory ref. P113HR4801), is the reference choice in the operating theatre for hospitals, private clinics and purchasing centres looking for a high-performance absorbable synthetic thread with a very competitive price-quality ratio. This presentation combines a ½ circle needle with cylindrical body and conical point (Taperpoint) of 48 mm (HR 48), USP 1 gauge and 90 cm violet fluted thread.
Each unit is supplied sterile and ready to use, in a box of 12 units with batch traceability, in a B2B format aimed at hospital replenishment, tenders and public procurement. Its Prime quality guarantees superior performance in tissue approximation, ligatures and general surgery, with a rate of numerous interventions with full confidence.
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that favours the passage of the thread through tissue, very smooth handling, low memory and firm, secure knot tying, even in medium gauges such as USP 1.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity. The thread retains 75% of tensile strength at 2 weeks, 50% at 3 and 40% at 4, a profile ideal for tissues requiring support for 2 to 4 weeks of healing while they recover their own resistance.
The ½ circle needle with cylindrical body and conical point (Taperpoint) penetrates by separating the fibres without cutting them, which minimises trauma to soft and friable tissues; the fluted violet colouring ensures optimal visibility of the thread on the surgical field. Product sterilised by ethylene oxide, single-use and with no possibility of re-sterilisation; minimal tissue reaction and excellent tensile strength.
3. Technical Specifications
3.1. Technical data sheet for reference AMP113HR4801
| Characteristic | Specification |
|---|---|
| Reference (SKU Cahnos) | AMP113HR4801 (factory ref. P113HR4801) |
| Range / Quality | Prime (premium range) |
| Material | 100% Polyglycolic acid (PGA), absorbable by hydrolysis |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 1 (metric 4), conforming to USP/EP Pharmacopoeia |
| Thread colour | Violet grooved |
| Thread length | 90 cm (1 needle per thread) |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Conical Taperpoint, atraumatic |
| Needle size | 48 mm (HR 48 Prime) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Minimum order | 30 units |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis |
Predictable and controlled absorption, with minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate.
4. Equivalences and Cross-References
The coated braided polyglycolic acid (PGA) suture belongs to the family of medium-absorption synthetic absorbable multifilament sutures most established in surgical practice (classic Dexon-type family). By polymer composition (PGA homopolymer), braided structure, coating, hydrolysis absorption profile (60–90 days) and tension retention, it is comparable at category level with the polylactin 910 and PGA lines on the international market. The verified homologous reference in the official manufacturer catalogue and authorised distribution in the closest configuration is as follows:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL (polyglactin 910) braided coated – CTX taper point needle 48 mm, USP 1, violet, 90 cm | J371H | Comparable by category (not interchangeable 1:1) | Same ½ circle conical point needle of 48 mm, same USP 1 gauge, same violet colour and same thread length (90 cm); the composition differs (PGLA 90/10 glycolide-L-lactide copolymer versus PGA homopolymer) and the declared absorption window (56–70 days versus 60–90 days). Code verified in the Ethicon catalogue and authorised distribution (presentation in box of 36 units). |
At category level, they are also homologous lines of medium-absorption absorbable braided suture: B. Braun (Safil, PGLA), Medtronic (Polysorb), SMI (Surgicryl PGA), DemeTECH (DemeSORB PGA) and Assut (AssuCryl PGA). The polylactin 910 ranges share the absorbable multifilament category but differ in chemical composition and absorption window, so they are not interchangeable 1:1 without technical validation. Within the Cahnos catalogue, the closest reference in polylactin 910 with the same configuration is P1L13HR4801 (PGLA Prime, HR 48 mm needle, USP 1, violet, 90 cm, absorption 56–72 days).
There is no equivalence table validated by the manufacturer that cross-references this specific configuration (Prime multifilament PGA, ½ circle conical Taperpoint needle HR 48 mm, USP 1 gauge, 90 cm violet thread) against the aforementioned commercial houses; consult the technical department before use in tenders. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (48 mm), ½ curvature, point family (conical), configuration (single needle), thread length (90 cm) and colour.
5. Selection tips and variants of interest
USP 1 gauge (metric 4) is indicated for tissues requiring medium-high resistance: aponeurosis, fascia, muscular planes, moderate-high tension closures and ligatures. The conical point (Taperpoint) separates the fibres without cutting them, ideal for soft and friable tissues; if the tissue is very delicate, the most atraumatic option is the blunt point (HRN), while for fibrous and dense structures the triangular reverse-cutting point (HS) is recommended.
Verify the needle radius (HR 40, 45 or 48 mm) according to the depth and surgical area to be treated. Within the PGA Prime HR 48 family from Cahnos, the following variants of interest are offered:
| Reference | Recommended variant |
|---|---|
| AMP113HR4802 | PGA Prime USP 2, HR 48 mm needle, violet, 90 cm (larger gauge for deep planes) |
| AMP113HRN4801 | PGA Prime USP 1, HRN 48 mm blunt point needle, violet, 90 cm (maximum atraumatic) |
| AMP113HS4801 | PGA Prime USP 1, HS 48 mm reverse cutting needle, violet, 90 cm (firm and dense tissues) |
| AM113HR4801 | PGA USP 1, HR 48 mm needle, violet, 90 cm (same configuration in standard quality) |
| P1L13HR4801 | PGLA Prime USP 1, HR 48 mm needle, violet, 90 cm (absorption 56–72 days) |
If the protocol requires longer wound support (180–210 days), consider the polydioxanone (PDO) family. As it is a sterile single-use product, always check the integrity of the pouch and the expiry date before each procedure, keep the reference with the batch for traceability in the operating theatre and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalence validation with other houses, contact our technical-commercial team.