We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture Prime 2 – ½ Circle Cylindrical Conical Point Taperpoint Needle HR 48 mm – USP 2 (Metric 5) Gauge – Violet Braided Thread 75 cm – Ref. AM112HR4802H (Box of 12 units)

Original price was: 34,75 €.Current price is: 29,75 €.

Absorbable multifilament suture of polyglycolic acid (PGA) in Prime 2 quality, mounted with a ½ circle needle, cylindrical body and conical point (Taperpoint) of 48 mm (HR 48). Violet braided thread of USP 2 (metric 5) gauge and 75 cm length, coated with polycaprolactone and calcium stearate for smooth passage and secure knot. Predictable absorption by hydrolysis in 60–90 days, maintaining 75% of tensile strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterilised by ethylene oxide, single-use, with minimal tissue reaction. Indicated for tissue approximation, ligation and general surgery. Price per box of 12 units; minimum order of 30 units. Ref. AM112HR4802H.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 units por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM112HR4802H

Description

1. Introduction

The Absorbable Multifilament PGA Prime 2 Suture is the reference choice in the operating theatre for hospitals, private clinics and purchasing groups looking for a high-performance absorbable synthetic thread with a very competitive price-quality ratio. This presentation combines a ½ circle needle with cylindrical body and tapered point (Taperpoint) of 48 mm (HR 48), USP 2 gauge and 75 cm violet fluted thread.

Each unit is supplied sterile and ready to use, with the guarantee of professional distribution from Cahnos. Its Prime 2 design ensures superior performance in procedures requiring high safety and reliability: tissue approximation, ligatures, deep planes and general surgery.

2. Technical explanation of the product and procedure

Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, very smooth handling, low memory and firm, secure knot tying, even in larger diameter gauges such as USP 2.

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, without depending on the patient’s enzymatic activity. The thread retains 75% of its tensile strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks, an ideal profile for tissues requiring support for 2 to 4 weeks of healing.

The ½ circle needle with cylindrical body and tapered point (Taperpoint) penetrates by separating the fibres without cutting them, which minimises trauma to soft tissues; the violet fluted colouring ensures optimal visibility of the thread on the surgical field. Sterilisation by ethylene oxide; sterile single-use product, not for re-sterilisation.

3. Technical Specifications

3.1. Technical data sheet of the reference

Characteristic Specification
Reference (SKU) AM112HR4802H
Range / Quality PREMISUT, Prime 2 quality
Material 100 % Polyglycolic acid (PGA) multifilament
Coating Polycaprolactone and calcium stearate
Thread structure Braided multifilament with grooved finish
Colour Violet (also available colourless)
Gauge USP 2 (metric 5)
Thread length 75 cm (1 strand)
Needle shape ½ circle (1/2)
Needle body Cylindrical
Needle tip Conical (Taperpoint)
Needle size 48 mm (HR 48)
Absorption mechanism Hydrolysis
Absorption period 60–90 days
Sterilisation Ethylene oxide (EO), single-use, not for re-sterilisation
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 %
3 weeks 50 %
4 weeks 40 %
Total absorption 60–90 days, by hydrolysis

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a totally predictable absorption rate.

3.3. Presentation and ordering conditions

Value Value
Presentation Box of 12 units (individual sterile unit)
Minimum order 30 units
Format Sterile, single-use

4. Equivalences and Cross-References

The polyglycolic acid (PGA) suture belongs to the family of synthetic absorbable braided sutures of medium absorption. By polymer composition (PGA homopolymer), braided structure, coating, hydrolysis absorption profile (60–90 days) and tensile retention, it is comparable at category level (not interchangeable 1:1) with international market lines: Ethicon (Johnson & Johnson) with its Coated VICRYL / VICRYL Plus range (coated braided polyglactin 910, violet; differs in copolymer material PGLA 90/10 versus PGA homopolymer and in absorption window 56–72 days), B. Braun with Safil (braided PGLA violet), Medtronic / Covidien with Polysorb, SMI with Surgicryl, Assut with Assucryl 910 and Laboratorio Aragó (HR/TC needle series of ½ circle cylindrical). There is no equivalence table validated by the manufacturer that cross-references these brands for the configuration of tapered needle HR 48 mm, USP 2 gauge and 75 cm thread; the lines cited are provided as a functional category comparison and must be verified field by field (gauge, thread length, needle radius and coating) before any formal substitution in a tender.

There is no equivalence table validated by the manufacturer; consult the technical department before use in a tender.

Within the same manufacturer and family PREMISUT, the references with equivalent or very similar configuration are:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
PREMISUT (Cahnos) PGA Prime Heavy USP 2, HR 48 mm needle, violet, 75 cm AMP112HR4802H Comparable by category (not interchangeable 1:1) Same HR 48 mm needle, same gauge, colour and length; differs in Prime Heavy quality versus Prime 2.
PREMISUT (Cahnos) PGA Prime 2 USP 1, HR 48 mm needle, violet, 75 cm AM112HR4801H Comparable by category (not interchangeable 1:1) Same needle and length; smaller gauge (USP 1) for areas of lower traction.
PREMISUT (Cahnos) PGA Heavy USP 2, HR 40 mm needle, violet, 75 cm AM112HR4002H Comparable by category (not interchangeable 1:1) Same gauge with HR 40 mm needle (smaller radius), for surgical fields with more limited access.

For a formal substitution of references in protocol or tender, consult our technical-commercial department.

5. Selection tips and variants of interest

USP 2 gauge (metric 5) is indicated for tissues requiring greater initial strength: deep planes, fascia, aponeurosis, high-tension closures and ligatures. The tapered point (Taperpoint) separates fibres without cutting them, ideal for soft and friable tissues; if the tissue is very delicate, the most atraumatic option is the blunt point, while for fibrous and dense structures the trocar point is recommended.

Check the needle radius (HR 40, 45 or 48 mm) according to the depth and surgical area to be treated. Within the Cahnos PGA Prime family, variants are offered in gauge 2/0 (AM112HR4020), USP 1 (AM112HR4801H) and HR 40 mm radius (AM112HR4002H); if you prefer a polyglactin 910 alternative with an absorption window of 56–72 days, consult the PGLA family. For longer strength retention needs (180–210 days), the polydioxanone (PDO) family is the recommended alternative.

As it is a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. Consult our technical-commercial team for special volume conditions: minimum order of 30 units, with scheduled deliveries for hospitals, clinics and purchasing groups.

Additional information

Manufacturer reference

112HR4802H

Material

100% polyglycolic acid (PGA) multifilament braided

Coating

Polycaprolactone and calcium stearate

Gauge

USP 2 (metric 5)

Colour

Violet grooved

Needle body

Cylindrical

Needle tip

Conical (Taperpoint)

Needle size

48 mm (HR 48)

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO), single-use

Tissue reaction

Minimal

Presentation

Box of 12 units

Minimum order

30 units

Indications

Tissue approximation, ligatures and general surgery

Medida de aguja

HR 48

Usp

2

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal, Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture Prime 2 – ½ Circle Cylindrical Conical Point Taperpoint Needle HR 48 mm – USP 2 (Metric 5) Gauge – Violet Braided Thread 75 cm – Ref. AM112HR4802H (Box of 12 units)”

Your email address will not be published. Required fields are marked *