We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture Premisut – ½ Circle Cylindrical Taper Point Needle (Taperpoint) HR 48 mm – Gauge USP 2 (Metric 5) – Violet Fluted Thread 90 cm – Ref. 113HR4802 – Box of 12 units

Original price was: 31,42 €.Current price is: 21,50 €.

Multifilament absorbable polyglycolic acid (PGA) suture from the Premisut range, ref. 113HR4802 (SKU AM113HR4802), mounted with ½-circle needle, cylindrical body and taper point (taperpoint), 48 mm (HR 48). Gauge USP 2 (metric 5), 90 cm violet fluted thread, coated with polycaprolactone and calcium stearate. Predictable absorption by hydrolysis in 60–90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterile by ethylene oxide, single-use, minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and general surgery. Price per box of 12 sterile units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM113HR4802

Description

1. Commercial Introduction

The absorbable multifilament polyglycolic acid (PGA) suture from the Premisut range, reference 113HR4802 (SKU AM113HR4802), is the reference choice in the operating theatre for hospitals, private clinics, purchasing groups and wholesalers seeking a high-performance synthetic absorbable thread with an excellent price-quality ratio in B2B procurement and tenders.

It incorporates a ½ circle needle with a cylindrical body and taper point (taperpoint) of 48 mm, gauge USP 2 and violet fluted thread of 90 cm coated with polycaprolactone and calcium stearate: a combination designed for the approximation of soft tissues, deep planes, ligatures and general surgery. Each unit is supplied sterile by ethylene oxide and ready to use, in individual sachets with batch traceability.

2. Technical Explanation

Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration facilitates the passage of the thread through tissue, reduces friction and the sawing effect, offers very smooth handling and guarantees firm and secure knot tying, even in high working gauges such as USP 2.

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance that the body metabolises without generating significant tissue reaction. The tensile strength retention profile maintains the necessary support during the critical phase of healing (75% at 2 weeks, 50% at 3 and 40% at 4).

The ½ circle needle (approx. 180°) with cylindrical body and taper point (taperpoint) penetrates by separating the fibres without cutting them, minimising trauma to soft and friable tissues. The violet colour ensures optimal visibility on the surgical field. Single-use product, with no possibility of re-sterilisation.

3. Technical Specifications

3.1. General characteristics (Ref. 113HR4802)

Parameter Specification
Factory reference 113HR4802
Reference (SKU Cahnos) AM113HR4802
Range / Quality PREMISUT – Normal quality
Thread material 100 % polyglycolic acid (PGA), synthetic absorbable
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 2 (metric 5 – EP)
Thread colour Violet grooved
Thread length 90 cm
Needle shape ½ circle (approx. 180°)
Needle body Cylindrical
Needle tip Taperpoint
Needle size 48 mm (HR 48), 1 needle per thread
Absorption mechanism Hydrolysis (60–90 days)
Sterilisation Ethylene oxide (EO); single-use, non-reesterilizable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 sterile units (individual pouches)
Minimum order 30 boxes
Regulatory standard Conforms to USP/EP Pharmacopoeia for synthetic absorbable sutures

3.2. Tensile strength retention profile

Post-implantation time Retained tensile strength
2 weeks 75% of initial strength
3 weeks 50% of initial strength
4 weeks 40% of initial strength
Complete absorption 60–90 days by hydrolysis

Predictable absorption by hydrolysis with minimal tissue reaction, excellent tensile strength and optimal knot tying, conforming to USP / European Pharmacopoeia.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia

USP size Metric measurement (EP) Approximate thread diameter
2/0 3 0.30 – 0.349 mm
0 3.5 0.35 – 0.399 mm
1 4 0.40 – 0.499 mm
2 (this product) 5 0.50 – 0.599 mm

The thread diameter complies with the official ranges of the USP Pharmacopoeia for synthetic absorbable sutures, without exceeding its limits.

4. Equivalences and Cross-References

Braided multifilament coated polyglycolic acid (PGA) with medium absorption (60–90 days) is one of the most widely used synthetic absorbables in general surgery and ligatures. The specific configuration of this data sheet —PGA homopolymer, ½ circle HR 48 mm taper point (taperpoint) needle, USP 2 gauge, 90 cm violet thread— has been compared with the main homologous families on the market. The closest external reference located and verified in terms of gauge, length, colour and needle geometry is the following:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) Coated VICRYL® (polyglactin 910, braided coated multifilament, violet, TP-1 taper point needle 48 mm, ½ circle, 90 cm) J585G (GTIN 30705031467600) Comparable by category (not interchangeable 1:1) They match in USP 2 gauge, 90 cm length, violet colour, ½ circle 48 mm needle with taper point and coated braided structure. They differ in the polymer (polyglactin 910 copolymer versus PGA homopolymer) and the absorption profile (56–72 days versus 60–90 days). Code confirmed in official manufacturer sources and authorised distribution; consult the technical data sheet before substituting in a tender.

Other commercial houses with homologous families of medium-absorption braided absorbable suture —B. Braun with Safil® (coated braided PGA; glyconate coating versus polycaprolactone and calcium stearate), Medtronic with the braided polyglactin 910 range such as Polysorb, SMI with Surgicryl® PGA or DemeTECH with DemeSORB® PGA— offer products in the same clinical category, but no confirmed code has been found in official sources for the exact configuration USP 2 + HR 48 mm taper point needle + 90 cm thread + violet.

There is no equivalence table validated by the manufacturer that cross-references this specific reference with closed codes from other brands; consult the technical department before using in a tender. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (48 mm), ½ curvature, point family (taper/taperpoint), thread length (90 cm) and colour. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference.

5. Selection tips and variants of interest

USP 2 gauge (metric 5) is indicated for tissues requiring high initial strength: deep planes, fascia, aponeurosis, high-tension closures and ligatures in general and digestive surgery. The ½ circle needle with 48 mm taper point is recommended for soft, friable or lax tissues, where the atraumatic point separates the fibres without cutting them; if the tissue is dense or fibrous, consider the trocar point (tapercut), and for very firm structures with clean cutting, the reverse cutting triangular point (HS). The 90 cm thread offers sufficient strand for medium-length continuous sutures and multiple ligatures.

Reference (SKU) Variant of interest
AM113HR4802 PGA USP 2, HR 48 mm taper point needle, violet, 90 cm (current product)
AM118HR4802 PGA USP 2, same HR 48 mm needle, violet, 70 cm (shorter thread)
AM113HR4502 PGA USP 2, HR 45 mm taper point needle, violet, 90 cm (intermediate needle)
AM113HR4002 PGA USP 2, HR 40 mm taper point needle, violet, 90 cm (shorter needle, reduced fields)
AM113HRT4802 PGA USP 2, HRT 48 mm trocar needle, violet, 90 cm (cutting point for dense tissues)
1L13HR4802 Polyglactin 910 USP 2, HR 48 mm taper point needle, violet, 90 cm (absorption 56–72 days)
1L23HR4802 Polyglactin 910 USP 2, HR 48 mm taper needle, undyed, 90 cm (maximum discretion)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place protected from sunlight. For longer strength retention requirements (180–210 days), the polydioxanone (PDO) family is the recommended alternative. For special B2B conditions, volume orders or confirmation of equivalences for tenders, contact our technical-commercial team.

Additional information

Manufacturer reference

113HR4802

Product line

PREMISUT

Material

100% polyglycolic acid (PGA), braided multifilament

Coating

Polycaprolactone and calcium stearate

Gauge

USP 2 (metric 5)

Colour

Violet grooved

Needle body

Cylindrical

Needle tip

Conical (Taperpoint)

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 units

Minimum order

30 boxes

Regulatory standard

Conforms to USP / European Pharmacopoeia

Medida de aguja

HR 48

Usp

2

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture Premisut – ½ Circle Cylindrical Taper Point Needle (Taperpoint) HR 48 mm – Gauge USP 2 (Metric 5) – Violet Fluted Thread 90 cm – Ref. 113HR4802 – Box of 12 units”

Your email address will not be published. Required fields are marked *