Description
1. Commercial Introduction
The absorbable multifilament suture of polyglycolic acid (PGA) from the Premisut range, reference 118HR4002 (SKU AM118HR4002), is the reference surgical closure solution for hospitals, private clinics, operating theatres and purchasing centres looking for a high-performance synthetic absorbable thread with an excellent price-quality ratio in B2B procurement and tenders.
It incorporates a ½ circle needle with a cylindrical body and conical point (Taperpoint) of 40 mm, USP 2 gauge and a 70 cm grooved violet thread: a combination designed for the approximation of soft tissues, deep planes, ligatures and general surgery. Each unit is supplied sterile and ready to use, with fully predictable absorption and reliable mechanical behaviour during the critical healing period.
2. Technical explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that favours the passage of the thread through tissue, reduces friction and the sawing effect, offers very smooth handling, low memory and guarantees firm and secure knot tying, even in high working gauges such as USP 2 (metric 5).
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, which the body metabolises without generating significant tissue reaction. The ½ circle needle with cylindrical body and conical point (Taperpoint) penetrates by separating the fibres without cutting them, minimising trauma to soft and friable tissues; the grooved violet colour ensures optimal visibility of the thread on the surgical field. The product is sterilised by ethylene oxide and is single-use, with no possibility of re-sterilisation.
3. Technical Specifications
3.1. General characteristics (Ref. AM118HR4002)
| Parameter | Specification |
| Reference (SKU Cahnos) | AM118HR4002 |
| Manufacturer reference | 118HR4002 |
| Range / Quality | PREMISUT – Normal quality |
| Thread material | 100 % polyglycolic acid (PGA), synthetic absorbable |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 2 (metric 5 – EP) |
| Thread colour | Violet grooved |
| Thread length | 70 cm (1 thread) |
| Needle shape | ½ circle (approx. 180°) |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), tapered and atraumatic |
| Needle size | 40 mm (HR 40), 1 needle per thread |
| Absorption mechanism | Hydrolysis (60-90 days) |
| Sterilisation | Ethylene oxide (EO); single-use, non-reesterilizable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 sterile units (individual pouches) |
| Minimum order | 30 boxes |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for synthetic absorbable sutures |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
| 2 weeks | 75% of initial strength |
| 3 weeks | 50% of initial strength |
| 4 weeks | 40% of initial strength |
| Complete absorption | 60-90 days by hydrolysis |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate and in accordance with the USP/European Pharmacopoeia.
3.3. Presentation and ordering conditions
| Value | Value |
| Presentation | Box of 12 units (individual sterile unit) |
| Minimum order | 30 units |
| Format | Sterile, single-use |
4. Equivalences and Cross-References
The polyglycolic acid (PGA) suture belongs to the family of synthetic braided absorbable sutures with medium absorption. Due to the polymer composition (PGA homopolymer), braided structure, coating, hydrolysis absorption profile (60-90 days) and tensile retention, it is comparable at category level (not interchangeable 1:1) with homologous lines on the international market:
- Ethicon (Johnson & Johnson): Coated VICRYL® / VICRYL® Plus range (coated braided polyglactin 910, violet; differs in material, PGLA 90/10 copolymer versus PGA homopolymer, and in absorption window of 56-72 days).
- B. Braun: Safil® (violet braided PGLA).
- Medtronic / Covidien: Polysorb® and Dexon® (absorbable braided ranges; Dexon is 100% PGA).
- SMI: Surgicryl® PGA (braided polyglycolic acid).
- DemeTECH: DemeSORB® PGA.
- Assut: Assucryl® (absorbable braided range).
- Laboratorio Aragó: Atramat, HR/TC needle series of ½ circle cylindrical.
No exact code from another brand has been found in official sources that matches field by field (USP 2 gauge + 40 mm HR conical needle + 70 cm violet thread + PGA homopolymer) with the exact configuration of this datasheet. There is no equivalence table validated by the manufacturer; consult the technical department before using in a tender. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (40 mm), ½ curvature, point family (conical/taperpoint), thread length (70 cm) and colour. The copolymeric polyglactin 910 ranges (Vicryl, Polysorb, Safil) are chemically different from PGA homopolymer and should not be treated as 1:1 interchangeable without validation from the pharmacy service or the technical department.
5. Selection tips and variants of interest
USP 2 gauge (metric 5) is indicated for tissues requiring high initial strength: deep planes, fascia, aponeurosis, high-tension closures and ligatures in general and digestive surgery. The ½ circle needle with conical point (Taperpoint) of 40 mm is recommended for soft, friable or lax tissues, where the atraumatic point separates the fibres without cutting them; if the tissue is dense or fibrous, consider the trocar point (tapercut), and for very firm structures with clean cutting, the reverse cutting triangular point (HS).
Within the PGA family of Cahnos, the variants of interest for this configuration are:
| Reference (SKU) | Variant of interest |
| AM118HR4002 | PGA USP 2, HR 40 mm taperpoint needle, violet, 70 cm (current product) |
| AMP118HR4002 | PGA Prime quality, same HR 40 mm needle, USP 2, violet, 70 cm (premium range) |
| AM113HR4002 | PGA USP 2, same HR 40 mm needle, violet, 90 cm (longer thread length) |
| AM118HR4502 | PGA USP 2, HR 45 mm conical needle, violet, 70 cm (intermediate needle) |
| AM118HR4802 | PGA USP 2, HR 48 mm conical needle, violet, 70 cm (longest needle) |
| AM118HR4001 | PGA USP 1, same HR 40 mm needle, violet, 70 cm (smaller gauge) |
| AM112HR4002H | PGA USP 2, reinforced Heavy HR 40 mm needle, violet, 75 cm (greater robustness) |
| 1L18HR4002 | Polyglactin 910 USP 2, HR 40 mm needle, violet, 70 cm (absorption 56-72 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. For longer tensile strength retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or confirmation of equivalences for tenders, contact our technical-commercial team.





Reviews
There are no reviews yet.