We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture (Polyglycolic Acid) – ½ Circle Cylindrical Conical Taperpoint Needle HR 45 mm – USP 1 Gauge (Metric 4) – Violet Fluted Thread 70 cm – Box of 12 units – Ref. 118HR4501

Original price was: 34,90 €.Current price is: 26,10 €.

Absorbable multifilament suture, 100% polyglycolic acid (PGA) from the Premisut range, reference 118HR4501, with a ½ circle needle, cylindrical body and 45 mm Taperpoint conical point (HR45), USP 1 gauge (metric 4) and 70 cm violet fluted thread coated with polycaprolactone and calcium stearate. Predictable absorption by hydrolysis in 60–90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks. Sterile by ethylene oxide, single-use, minimal tissue reaction and optimal knot security. Indicated for tissue approximation, ligatures and general surgery. Presentation in a box of 12 units; minimum order of 30 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 units por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM118HR4501

Description

1. Commercial Introduction

The absorbable multifilament suture of polyglycolic acid (PGA), reference 118HR4501 from the Premisut range, is the reference surgical closure solution for hospitals, general surgery operating theatres, private clinics and B2B purchasing centres looking for a high-performance absorbable synthetic thread with an excellent price-quality ratio in procurement and tenders.

It incorporates a ½ circle needle with cylindrical body and Taperpoint conical point of 45 mm, USP 1 gauge and 70 cm violet grooved thread: a combination designed for the approximation of soft tissues, deep planes, ligatures and general surgery. Each unit is supplied sterile and ready to use, in an individual sachet with batch traceability, in a box of 12 units.

2. Technical explanation of the product and procedure

Polyglycolic acid (PGA) is a 100 % absorbable synthetic polymer presented in a braided multifilament structure with a grooved finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, reduces friction and the sawing effect, offers very smooth handling, low shape memory and guarantees firm and secure knot tying, even in medium-high diameter gauges such as USP 1.

Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, which the body metabolises without causing relevant tissue reaction. The thread retains 75% of its tensile strength at 2 weeks, 50% at 3 and 40% at 4, an ideal profile for tissues that require support for 2 to 4 weeks of healing while they recover their own resistance.

The ½ circle needle (approx. 180°) with cylindrical body and Taperpoint conical point penetrates separating the fibres without cutting them, minimising trauma to soft and friable tissues; the violet grooved colouration ensures optimal visibility of the thread on the surgical field. Product sterilised by ethylene oxide (EO), single-use and with no possibility of re-sterilisation.

3. Technical Specifications

3.1. General characteristics of reference 118HR4501

Parameter Specification
Reference (SKU Cahnos) AM118HR4501 · Factory ref. 118HR4501
Range / Quality Premisut – Normal quality
Suture type Absorbable synthetic multifilament
Thread material 100 % polyglycolic acid (PGA)
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 1 (metric 4); approximate diameter 0.40 – 0.499 mm (USP/EP)
Thread colour Grooved violet (also available undyed)
Thread length 70 cm (1 thread, 1 needle)
Needle shape ½ circle (1/2 circular)
Needle body Cylindrical
Needle tip Conical (Taperpoint), tapered and atraumatic
Needle size 45 mm (HR 45)
Absorption mechanism Hydrolysis
Absorption period 60 – 90 days
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Tissue reaction Minimal, with excellent tensile strength and knot security
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (individual sterile unit)
Minimum order 30 units
Regulatory standard Conforms to USP Pharmacopoeia / European Pharmacopoeia (EP) for synthetic absorbable sutures

3.2. Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75% of initial strength
3 weeks 50% of initial strength
4 weeks 40% of initial strength
Total absorption 60 – 90 days, by hydrolysis

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Absorption range and retention values copied literally from the manufacturer’s documentation, without extension of limits.

3.3. Gauge equivalence according to USP/EP Pharmacopoeia

USP size Metric measurement (EP) Approximate thread diameter
2/0 3 0.30 – 0.349 mm
0 3.5 0.35 – 0.399 mm
1 (this product) 4 0.40 – 0.499 mm
2 5 0.50 – 0.599 mm

4. Equivalences and Cross-References

Braided coated multifilament polyglycolic acid (PGA) of medium absorption (60–90 days) is one of the most well-established synthetic absorbables in surgical practice (classic family type «Dexon»). By polymer composition, braided structure, coating, hydrolysis absorption profile and tensile retention, this reference is comparable at category level (not 1:1 interchangeable) with the following homologous configuration on the international market, verified in the manufacturer’s official catalogue and authorised distribution:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) Coated VICRYL – braided coated polyglactin 910, violet J331H Comparable by category (not interchangeable 1:1) USP 1, 90 cm violet thread and CT-2 taper point needle of 40 mm in ½ circle: gauge, colour, curvature and conical point family match. They differ in polymer (PGLA 90/10 copolymer versus PGA homopolymer), needle size (40 versus 45 mm), thread length (90 versus 70 cm) and absorption window (56–72 days versus 60–90 days). Code verified in official catalogue and authorised distribution.
Ethicon (Johnson & Johnson MedTech) Coated VICRYL – braided coated polyglactin 910, violet V366H Comparable by category (not interchangeable 1:1) USP 1, 90 cm violet thread and CTX taperpoint needle of 48 mm in ½ circle: gauge, colour, curvature and point match. They differ in polymer (PGLA 910 versus PGA), needle size (48 versus 45 mm) and absorption window (56–72 days versus 60–90 days).

As homologous families of 100 % braided coated PGA that must be verified reference by reference in their official datasheet before any formal substitution, the lines Safil (B. Braun), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH), AssuCryl (Assut) and the historical range Dexon II (Medtronic/Covidien) are cited, always checking polymer, USP 1 gauge, ½ circle curvature, 45 mm conical point, single needle attachment, 70 cm thread length and violet colour. The copolymer polyglactin 910 ranges (Vicryl, Polysorb, Novosyn) are chemically different from PGA homopolymer and should not be treated as 1:1 interchangeable without validation from the pharmacy service or the technical department.

There is no equivalence table validated by the manufacturer that cross-references this specific configuration (multifilament PGA, ½ circle conical Taperpoint HR45 needle of 45 mm, USP 1 gauge, 70 cm violet thread) with closed codes from other commercial houses; consult the technical department before using in tenders. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.

5. Selection tips and variants of interest

USP 1 gauge (metric 4) is indicated for tissues requiring high initial strength: fascia, aponeurosis, muscular planes, abdominal wall and moderate-high tension closures. The ½ circle conical Taperpoint needle separates the fibres without cutting them, ideal for soft and friable tissues; if the tissue is very delicate, the most atraumatic option is the blunt point (HRN), while for fibrous and dense structures the trocar point (Tapercut) or the reverse cutting triangular point (HS) is recommended. Also verify the needle radius (HR 40, 45 or 48 mm) according to the depth and surgical area to be treated.

Reference (SKU) Variant of interest
AM118HR4501 (118HR4501) PGA USP 1, conical needle HR 45 mm, violet, 70 cm (current product)
AMP118HR4501 (P118HR4501) Prime quality PGA, same HR 45 mm needle, USP 1, violet, 70 cm (premium range, same configuration)
AM113HR4501 (113HR4501) PGA USP 1, same HR 45 mm needle, violet, 90 cm (longer thread length)
AM118HR4502 (118HR4502) PGA USP 2, same HR 45 mm needle, violet, 70 cm (larger gauge)
AM118HR4001 (118HR4001) PGA USP 1, HR 40 mm taper needle, violet, 70 cm (smaller needle radius, reduced surgical fields)
AM118HR4801 (118HR4801) PGA USP 1, conical needle HR 48 mm, violet, 70 cm (larger needle radius)
1L18HR4501 Polyglactin 910 (PGLA) USP 1, HR 45 mm needle, violet, 70 cm (absorption 56–72 days)

If the procedure requires longer wound support (180–210 days), the polydioxanone (PDO) family is the recommended alternative. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight, below 30 °C. For special B2B volume conditions, hospital supply contracts or equivalence validation for tendering, contact our technical-commercial team.

Additional information

Manufacturer reference

118HR4501

Material

100% polyglycolic acid (PGA)

Thread structure

Multifilament braided fluted

Coating

Polycaprolactone and calcium stearate

Gauge

USP 1 (metric 4)

Colour

Violet grooved

Tip type

Conical Taperpoint (cylindrical body)

Needle size

45 mm (HR45)

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO)

Use

Single-use, not re-sterilisable

Presentation

Box of 12 units

Minimum order

30 units

Indications

Tissue approximation, ligatures and general surgery

Medida de aguja

HR 45

Usp

1

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture (Polyglycolic Acid) – ½ Circle Cylindrical Conical Taperpoint Needle HR 45 mm – USP 1 Gauge (Metric 4) – Violet Fluted Thread 70 cm – Box of 12 units – Ref. 118HR4501”

Your email address will not be published. Required fields are marked *