Description
The absorbable multifilament polyglycolic acid (PGA) suture from the Premisut range, factory reference 112HR1730 (SKU AM112HR1730), is the most proven medium-term absorbable synthetic solution on the market, designed for the professional who demands predictable performance, excellent tensile strength and high knot security. This presentation includes an atraumatic ½ circle needle with cylindrical body and Taperpoint conical point of 17 mm (HR17), USP gauge 3/0 (metric 2) and a 75 cm braided violet grooved thread. It is the ideal choice for the approximation of soft tissues, ligatures and general surgery, in a professional format of a box of 12 units, designed for stock management in operating theatres, clinics and purchasing centres, with special B2B conditions for hospitals and volume buyers (minimum order of 30 boxes). Price per box.
2. Technical explanation of the material and procedure
Polyglycolic acid (PGA) is a 100 % absorbable synthetic polymer presented in a braided multifilament structure and coated with polycaprolactone and calcium stearate. This configuration gives the thread a regular (grooved) surface that favours sliding through tissue, smooth handling, low memory and firm, secure knot tying, even in fine gauges such as USP 3/0.
Its absorption occurs by hydrolysis, a uniform process independent of the patient’s enzymatic activity, with total absorption between 60 and 90 days: during the first weeks of healing the thread retains the necessary tensile strength (75 % at 2 weeks, 50 % at 3 and 40 % at 4), just enough time for the tissue to recover its own strength.
The ½ circle needle with cylindrical body and conical point (Taperpoint geometry) of 17 mm separates the fibres without cutting effect: it is the most atraumatic configuration for delicate and friable tissues, with controlled passage and minimal injury along the penetration path. The grooved violet colour ensures optimal visibility of the strand on the surgical field, highly valued in deep planes. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference AM112HR1730
| Parameter | Specification |
|---|---|
| Reference (SKU) | AM112HR1730 |
| Factory reference | 112HR1730 |
| Brand / Range | Premisut – Standard quality |
| Suture type | Synthetic absorbable braided multifilament |
| Material | 100 % absorbable polyglycolic acid (PGA) |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament, grooved surface |
| USP / metric gauge | 3/0 (metric 2) |
| Thread diameter | 0.20 – 0.249 mm (USP/EP standard) |
| Thread colour | Braided violet (also available undyed) |
| Thread length | 75 cm |
| Swaged | Single needle (1xHR17) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | 17 mm (HR17) |
| Absorption mechanism | Hydrolysis |
| Total absorption | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Regulatory standard | USP/EP |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60 – 90 days, by hydrolysis |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.349 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 5/0 | 1 | 0.10 – 0.149 mm |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
4. Equivalences and Cross-References
Braided coated polyglycolic acid is the most proven absorbable multifilament raw material of medium absorption in surgical practice (classic family type ‘Dexon’). This Premisut reference, with hydrolysis absorption of 60–90 days, tensile strength retention of 75/50/40 % at 2/3/4 weeks and a single cylindrical Taperpoint needle of 17 mm, USP gauge 3/0 and 75 cm thread, is comparable at category level (not 1:1 interchangeable) with the homologous PGA line verified against an official source (manufacturer’s catalogue):
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| SMI (Belgium) | Surgicryl® PGA (braided coated polyglycolic acid, violet) | 11200117 – USP 3/0 (metric 2), ½ circle needle, round body, conical point HR 17 mm, 75 cm, violet (official SMI catalogue) | Comparable by category (not interchangeable 1:1) | Same polymer (PGA), same coating (polycaprolactone and calcium stearate at 1 %), same absorption 60–90 days, same needle geometry HR 17 mm (½ circle, conical point), same USP gauge 3/0 and same strand length of 75 cm; they differ only in the exact coating composition and the retention profile specific to each manufacturer. Verify IFU and commercial availability in the region before substituting. |
There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. At category level, homologous braided coated PGA lines also include: B. Braun Safil® (PGA range, violet), DemeTECH DemeSORB® PGA, Assut Sutures AssuCryl® PGA and the historical Medtronic Dexon® / Dexon II® range; however, no specific code with the exact combination of USP 3/0 + single HR17 needle + 75 cm thread has been confirmed in public sources for these manufacturers, so they cannot be tabulated as a closed reference. Polyglactin 910 lines (Ethicon Vicryl®, Safil® Quick in its PGLA variant, Medtronic Polysorb®) share the needle geometry and multifilament behaviour, but use a different copolymer (glycolide/L-lactide) with absorption of 56–72 days: they are comparable by category, not 1:1 interchangeable material to material. Any substitution must be validated code by code, verifying material, gauge, needle geometry (shape, body, point and size), attachment, strand length and presentation in the technical data sheet or IFU of each manufacturer.
5. Selection tips and variants of interest
The USP 3/0 gauge (metric 2) combines excellent initial tensile strength with a fine-to-medium diameter, indicated for the approximation of tissues under moderate tension: subcutaneous planes, closure of subcutaneous cellular tissue, ligation of medium-calibre vessels and general surgery, where reliable support is required during the first weeks of healing. The ½ circle conical-point needle of 17 mm (HR17) is the most atraumatic option for soft tissues and medium-sized fields, with controlled passage and minimal bleeding; the violet colour offers excellent visibility on the surgical field.
Variants and alternatives from the same Cahnos catalogue:
- AMP112HR1730: same HR17 configuration, USP 3/0, violet, 75 cm in Prime quality, for high-demand protocols (direct equivalent of the same family).
- AM112HR1740 / AM112HR1750: same HR17 needle in USP gauges 4/0 and 5/0, for finer tissues and lower tension.
- AM112HR1720: same HR17 needle in USP 2/0 gauge, for larger thread diameter and increasing tension.
- AM118HR1760: HR17 needle in USP 6/0 gauge, for very fine planes.
- AM112HR1350: same needle and gauge with HR13 needle (13 mm), for smaller radius accesses.
- AM118HR1730-2: double needle 2xHR17 in USP gauge 3/0, for continuous sutures with anchoring at both ends.
- 1L12HR1730 / P1L12HR1730: polyglactin 910 (PGLA) family with the same HR17 needle and USP 3/0 gauge, absorption of 56–72 days, to compare materials and unify stocks.
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to the healthcare centre. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, institutional rates or equivalents from other commercial houses, contact our technical-commercial team.