Description
1. Product Presentation
The absorbable multifilament suture made of polyglycolic acid (PGA) from the Prime range is the reference synthetic absorbable solution for professionals who demand predictable behaviour, excellent tensile strength and great security in knot tying. This presentation incorporates a ½ circle needle with a cylindrical body and a Taperpoint conical point of 13 mm (HR13), USP 5/0 gauge (metric 1) and a 75 cm violet braided fluted thread.
It is the ideal choice for approximating soft tissues, ligatures and general surgery, in a professional box format of 12 units, designed for stock management in operating theatres, clinics and purchasing centres, with special B2B conditions for hospitals and volume buyers.
2. Technical explanation of the material and procedure
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure, coated with polycaprolactone and calcium stearate. This configuration provides a regular (fluted) surface that favours the sliding of the thread through tissue, smooth handling, low memory and firm, secure knot tying, even in fine gauges such as USP 5/0.
Its absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days and independent of the patient’s enzymatic activity. During the first weeks of healing it maintains the necessary tensile strength (75% at 2 weeks, 50% at 3 weeks and 40% at 4 weeks), the precise time for the tissue to recover its own resistance.
The ½ circle needle with cylindrical body and conical point (Taperpoint geometry) combines an atraumatic point, which separates fibres without cutting effect, with smooth passage through tissue: it is the usual configuration for delicate tissues, deep planes and reduced-radius access. The violet colour of the thread guarantees optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference AMP112HR1350
| Parameter | Specification |
| Reference (SKU) | AMP112HR1350 |
| Factory reference | P112HR1350 |
| Brand / Range | Prime (multifilament PGA) |
| Material | 100 % polyglycolic acid (PGA), synthetic absorbable |
| Coating | Polycaprolactone and calcium stearate |
| Suture type | Synthetic absorbable braided multifilament |
| Thread structure | Braided multifilament, grooved surface |
| USP / metric gauge | 5/0 (metric 1) |
| Approximate diameter | 0.100 – 0.149 mm (USP/EP standard) |
| Thread colour | Violet |
| Thread length | 75 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | 13 mm (HR13) |
| Absorption mechanism | Hydrolysis (60–90 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Regulatory standard | USP/EP |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60–90 days, by hydrolysis |
3.3. Size equivalence
| USP size | Approximate diameter (USP/EP standard) | Metric size |
| 5/0 | 0.100 – 0.149 mm | 1 |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Single-use, not re-sterilisable. Price per box of 12 units.
4. Equivalences and Cross-References
Coated braided polyglycolic acid (PGA) is the most well-established absorbable multifilament raw material of medium absorption in surgical practice (classic Dexon-type family). This Prime reference, with hydrolysis absorption of 60–90 days, tensile strength retention of 75/50/40% at 2/3/4 weeks and a 13 mm Taperpoint cylindrical needle, is comparable by category (not 1:1 interchangeable) with the following homologous PGA lines from other manufacturers, verified against official catalogues and regulatory databases (GUDID):
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| SMI (Belgium) | Surgicryl® PGA (coated braided multifilament PGA, violet) | 11100113 – USP 5/0 (metric 1), 75 cm, HR13 needle (verified in authorised distributor catalogues and SMI) | Comparable by category (not interchangeable 1:1) | Same 100% coated PGA (polycaprolactone and calcium stearate at 1%), same USP 5/0 gauge, same HR13 needle (½ circle, cylindrical body, conical point) and same 75 cm length in violet; absorption 60–90 days and strength retention ≈50% at 21 days. Box of 12 units. Different manufacturer and own surface finish, so it is not 1:1 interchangeable without code-by-code validation. |
| B. Braun (Aesculap) | Safil® Violet (coated braided polyglycolic acid) | C1048007 / G1048007 – Safil Violet 5/0 (1) 70 cm HR13 (verified in GUDID, DI 04038653934362 / 04038653943982) | Comparable by category (not interchangeable 1:1) | Same 100% PGA, same HR13 needle geometry (½ circle, cylindrical body, conical point) and same USP 5/0 gauge in violet; 70 cm thread compared to 75 cm for this reference. Glyconate coating compared to polycaprolactone/calcium stearate and different retention profile (Safil ≈50% at 18–21 days compared to 50% at 3 weeks for this reference). |
Polyglactin 910 lines (for example Vicryl® from Ethicon, Novosyn® from B. Braun, Polysorb® from Medtronic or Assucryl® 910 from Assut) share a similar clinical and absorption profile, but use a different copolymer (glycolide/L-lactide) with absorption of 56–72 days: they are comparable by category, not 1:1 interchangeable material by material, and any substitution must be validated code by code, verifying material, gauge, needle geometry (shape, body, point and size) and presentation in the technical data sheet or IFU of each commercial house.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering.
5. Selection tips and variants of interest
The USP 5/0 gauge (metric 1) is indicated for fine tissues with low or moderate tension: mucosa, subcutaneous tissue, delicate planes and precision approximations. The 13 mm (HR13) ½ circle Taperpoint conical point needle is the most atraumatic option for these tissues and smaller-radius accesses.
Within the Cahnos catalogue, the following variants of interest are available:
- AM112HR1350: same HR 13 mm configuration, USP 5/0, violet 75 cm in standard quality, to optimise procurement costs.
- P1L12HR1350 / 1L12HR1350: polyglactin 910 (PGLA) family with the same HR 13 mm needle and USP 5/0 gauge in Prime and standard quality, absorption of 56–72 days, to compare suppliers and unify stocks.
- AMP112HR1360 / AM112HR1360: same HR 13 mm needle, USP 6/0 gauge, violet 75 cm (even finer diameter for microsurgery).
- AM118HR1340: HR 13 mm needle, USP 4/0 gauge, violet 70 cm (larger diameter for moderate tension).
If you need a longer retention profile (180–210 days) or a monofilament thread, the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for the healthcare facility. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalents from other commercial brands, contact our technical-commercial team.





Reviews