Description
1. Commercial Introduction
The Prime-quality multifilament absorbable polyglycolic acid (PGA) suture, reference AMP112HR2220, is the professional reference solution for the surgeon who demands secure closure, excellent thread handling and fully predictable absorption in the approximation of soft tissues, ligatures and general surgery. Its ½-circle needle with cylindrical body and 22 mm conical point guarantees atraumatic penetration that separates fibres without a cutting effect, minimising trauma to delicate structures. The 75 cm violet fluted thread offers optimal visibility over the surgical field and smooth sliding during suturing.
It is a synthetic, absorbable, sterile and single-use medical device, with an excellent quality-price ratio for the B2B supply of operating theatres, clinics, distributors, purchasing centres and ambulatory surgery units. Presentation in a box of 12 units with a minimum order of 30 boxes, ensuring the continuous supply of your healthcare centre.
2. Technical Explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration provides great flexibility, low shape memory, smooth passage through tissue, a low friction coefficient and firm, secure knot tying, even in medium gauges such as USP 2/0.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days and independent of the patient’s enzymatic activity. This profile maintains wound edge apposition during the critical healing phase (2 to 4 weeks) thanks to a tensile strength retention of 75 % at 2 weeks, 50 % at 3 and 40 % at 4. The ½-circle needle with cylindrical body and conical point (taperpoint) penetrates without a cutting effect, being especially suitable for friable and delicate tissues. The product is sterilised by ethylene oxide, is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference AMP112HR2220
| Characteristic | Specification |
|---|---|
| Reference (SKU) | AMP112HR2220 |
| Quality | Prime (PGA range) |
| Material | 100% polyglycolic acid (PGA), absorbable by hydrolysis |
| Coating | Polycaprolactone and calcium stearate (improved handling and reduced friction) |
| Suture type | Synthetic absorbable braided multifilament, ribbed finish |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Violet |
| Thread length | 75 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (taperpoint), atraumatic |
| Needle size | 22 mm (HR 22) |
| Absorption mechanism | Hydrolysis (60–90 days) |
| Sterilisation | Ethylene oxide (sterile, single-use) |
| Tissue reaction | Minimal, with excellent tensile strength and knot security |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60–90 days, by hydrolysis |
Complete absorption by hydrolysis between 60 and 90 days, with minimal tissue reaction, excellent tensile strength, optimal knot tying and a fully predictable absorption rate. Price per box of 12 units; minimum order of 30 boxes.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.349 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is one of the most well-established multifilament synthetic absorbable suture raw materials on the market, and its medium absorption profile (60–90 days) invites frequent comparisons with braided polyglactin 910 lines. At category level, this reference is comparable, not interchangeable 1:1, with the following homologous families on the international market: Ethicon (Johnson & Johnson) with its Vicryl line (polyglactin 910), B. Braun with Safil, Medtronic with Polysorb and with the historic DEXON PGA line, SMI with Surgicryl, Assut with Assucryl 910 and DemeTECH with DemeCRYL.
Differences to verify before any substitution: PGA is a homopolymer (100 % glycolide) while polyglactin 910 is a copolymer (90 % glycolide / 10 % L-lactide); the declared absorption is 60–90 days versus 56–72 days for PGLA; and the strength retention at 4 weeks is 40 % in PGA versus the usual 30–35 % values in polyglactin 910 lines. The needle configuration (½ circle, cylindrical body, 22 mm conical point), USP 2/0 gauge and 75 cm thread length must always be confirmed in the technical data sheet and IFU of the destination manufacturer.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The specific reference codes of the cited commercial houses have not been verified in primary sources for this exact configuration and remain pending confirmation with the manufacturer/distributor.
5. Selection tips and variants of interest
The USP 2/0 gauge (metric 3) offers an excellent balance between initial strength and manageability for soft tissues of moderate tension: skin, subcutaneous tissue, mucosa, muscle and ligatures, and is widely used in general and ophthalmic surgery. The ½-circle needle with 22 mm taperpoint conical point is the most atraumatic option for delicate and friable tissues; if greater penetration in firm, dense tissues is required, consider the trocar (HRT) or reverse cutting (HS) needles available in the same range. For tissues of minimal tension, consider a smaller gauge (3/0 or 4/0); for planes of greater tension, a larger gauge (0 or 1).
| Reference | Variant of interest in the Cahnos catalogue |
|---|---|
| AM112HR2220 | Standard PGA USP 2/0, HR 22 mm needle, violet, 75 cm (same configuration, standard quality) |
| 1L12HR2220 | PGLA (poliglactin 910) USP 2/0, HR 22 mm needle, violet, 75 cm (absorption 56–72 days) |
| P1L12HR2220 | PGLA Prime USP 2/0, HR 22 mm needle, violet, 75 cm (superior quality in PGLA) |
| 1L28HR2220 | PGLA USP 2/0, HR 22 mm needle, colourless, 70 cm (maximum discretion in the field) |
| 1L12HR2230 | PGLA USP 3/0, HR 22 mm needle, violet, 75 cm (fine gauge) |
| 1L28HR2240 | PGLA USP 4/0, HR 22 mm needle, colourless, 70 cm (very fine gauge) |
| AMP118HR2230VB | PGA Prime VisiBlack USP 3/0, high-visibility HR 22 mm needle, violet, 70 cm (greater needle contrast) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure the continuous supply of your healthcare centre. If you need a longer strength retention (180–210 days) or a monofilament profile, consider the polydioxanone (PDO) family available in the catalogue. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews