We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Prime Suture | 100% Polyglycolic Acid | ½ Circle Cylindrical Body Taperpoint Conical Point HR17 Needle (17 mm) | USP Gauge 4/0 (Metric 1.5) | Colourless Thread 70 cm | Ref. P128HR1740 · Box of 12 units

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament PGA Prime suture of 100% synthetic polyglycolic acid (PGA), factory reference P128HR1740 (SKU AMP128HR1740). Mounted on an atraumatic ½ circle needle, cylindrical body and 17 mm Taperpoint conical point (HR17 profile), USP gauge 4/0 (metric 1.5) and colourless fluted thread of 70 cm, coated with polycaprolactone and calcium stearate for smooth passage and a firm, secure knot. Predictable absorption by hydrolysis between 60 and 90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterile by ethylene oxide, single-use and minimal tissue reaction; indicated for soft tissue approximation, ligatures and general surgery. Presentation in a box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP128HR1740

Description

1. Commercial Introduction

The PGA Prime Absorbable Multifilament Suture from Cahnos is the choice of the professional who demands a resorbable thread with predictable handling, secure knotting and constant performance in the operating theatre. This configuration combines a braided strand of 100% synthetic polyglycolic acid (PGA), colourless and grooved, and 70 cm, with a half circle needle with cylindrical body and Taperpoint conical point of 17 mm (HR17 profile): the ideal option for approximation of soft tissues, ligatures and general surgery, with excellent value for money for hospital replenishment, purchasing centres and B2B tenders. Presentation in a box of 12 units with a minimum order of 30 boxes.

2. Technical Explanation

Polyglycolic acid (PGA) is a 100% synthetic polymer absorbable by hydrolysis, spun into a braided multifilament structure and coated with polycaprolactone and calcium stearate. This coating regularises the surface of the strand: it reduces friction when passing through tissues (less saw effect), improves sliding, minimises tissue reactivity and facilitates firm and secure knot tying, even in fine gauges such as USP 4/0.

Its degradation profile is designed for short-to-medium duration healing: it retains 75% of tensile strength at 2 weeks, 50% at 3 weeks and 40% at 4 weeks, completing absorption by hydrolysis between 60 and 90 days, independently of the patient’s enzymatic activity. The HR17 needle features a half circle curvature (160°) with a cylindrical body and Taperpoint conical point: the round body passes through soft tissues atraumatically and the conical point penetrates without aggressive cutting effect, avoiding enlargement of the exit hole. The colourless colour provides maximum discretion in the surgical bed. Product sterile by ethylene oxide (EO), single-use and non-reesterilisable.

3. Technical Specifications

3.1. Technical data sheet of the reference (Ref. P128HR1740 · SKU AMP128HR1740)

Parameter Specification
Factory reference P128HR1740 (official PGA Prime nomenclature)
Reference Cahnos (SKU) AMP128HR1740
Brand / quality Prime (premium range)
Thread material 100% polyglycolic acid (PGA), synthetic absorbable
Thread structure Braided coated multifilament, fluted finish
Coating Polycaprolactone and calcium stearate
Gauge / size USP 4/0 (metric 1.5), conforming to USP/EP Pharmacopoeia
Approximate thread diameter 0.15 – 0.199 mm (indicative according to Pharmacopoeia)
Thread length 70 cm (free end, without loop)
Thread colour Colourless (violet version available in the family)
Needle shape ½ circle (1/2 circular, 160°), cylindrical body
Needle tip Taperpoint conical (atraumatic)
Needle size HR 17 (17 mm), 1 needle per suture
Swaged 1 needle / 1 suture per unit
Absorption mechanism Hydrolysis; complete between 60 and 90 days
Sterilisation Ethylene oxide (EO); single-use, not re-sterilisable
Tissue reaction Minimal; excellent tensile strength and knot tying
Indications Approximation of soft tissues, ligatures and general surgery
Commercial presentation Box of 12 units (individual sterile sachets, batch traceability)
Regulatory standard Conforming to USP/EP Pharmacopoeia for synthetic absorbable sutures; medical device with CE marking

3.2. Absorption profile and tensile strength retention

Post-implantation time Retained tensile strength
2 weeks 75% of initial tensile strength
3 weeks 50% of initial tensile strength
4 weeks 40% of initial tensile strength
Complete absorption 60 – 90 days by hydrolysis (predictable and uniform rate)

The cited profile corresponds to the standard absorption formulation of the PGA line (60–90 days); it must not be confused with rapid absorption PGA (RAPID line, 40–45 days) nor with standard polyglactin 910 (56–72 days).

3.3. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
4/0 (this product) 1.5 0.15 – 0.199 mm
3/0 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.339 mm
5/0 1 0.10 – 0.149 mm

The diameter of the strand complies with the official ranges of the USP Pharmacopoeia for synthetic absorbable sutures, without exceeding its limits.

4. Equivalences and Cross-References

Coated braided multifilament polyglycolic acid (PGA) is the most widespread medium-duration synthetic absorbable in the surgical market, with an absorption profile of 60 to 90 days and a coating of polycaprolactone and calcium stearate. There is no equivalence table validated by the manufacturer that cross-references this reference with other brands in the exact configuration (PGA Prime, half circle needle HR 17 mm with conical point, USP 4/0 gauge, colourless 70 cm thread); consult the technical department before use in tenders.

Homologous families in the 100% coated braided PGA segment include Safil® (B. Braun), Surgicryl® PGA (SMI), DemeSORB® PGA (DemeTECH), Dexon II (Medtronic/Covidien), Assucryl (Assut) and Atramat (Resorba); as polyglactin 910 (PGLA) lines comparable by category —chemically different, absorption 56–72 days—, Coated VICRYL® / VICRYL® Plus (Ethicon), Novosyn® (B. Braun) and Polysorb (Medtronic). In all cases, property-by-property verification must be carried out —exact material, USP 4/0 gauge, multifilament structure, half circle curvature, conical point family, needle length of 17 mm, 70 cm strand, colour, assembly of 1 needle and CE/MDR regulatory classification— before any substitution; unverified cross-reference codes are not published. Within the system itself, the PGA Prime family offers the same material and absorption profile in other gauges, geometries and lengths (see block 5), which are fully interchangeable with each other respecting gauge and needle geometry. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.

5. Selection tips and variants of interest

The USP 4/0 gauge (metric 1.5) is a fine size, indicated for delicate and low-tension tissues: fine skin, mucosa, subcutaneous tissue, superficial planes and ligatures of fine-calibre vessels, where minimal trauma and aesthetic healing are sought. The HR17 half circle needle with Taperpoint conical point combines the sharp entry of the point with the non-traumatic passage of the cylindrical body: it is the recommended option for small fields and soft tissues where an atraumic passage is sought, without a broad cutting effect and with minimal bleeding. If you need to pass through firmer and denser tissues (skin, fascia, sclera), consider the trocar points (HRT) available in the same range. The colourless colour offers maximum discretion on the surgical field; if you prefer greater visibility of the strand, request the violet version of the same family.

Variant (SKU) Description
AMP128HR1740 (P128HR1740) PGA Prime – HR17 taperpoint – USP 4/0 colourless – 70 cm (current product)
AM128HR1740 (128HR1740) Standard PGA – HR17 taperpoint – USP 4/0 colourless – 70 cm (same configuration, standard range)
AMP128HR1730 (P128HR1730) PGA Prime – HR17 taperpoint – USP 3/0 colourless – 70 cm (slightly larger gauge)
AMP128HR1750 PGA Prime – HR17 taperpoint – USP 5/0 colourless – 70 cm (finer gauge)
AMP128HRT1740 PGA Prime – HRT17 trocar point tapercut – USP 4/0 colourless – 70 cm (denser tissues)
AMP128HR2240 PGA Prime – HR22 taperpoint – USP 4/0 colourless – 70 cm (22 mm needle, medium fields)
P1L28HR1740 PGLA polyglactin 910 – HR17 taperpoint – USP 4/0 colourless – 70 cm (absorption 56–72 days)

All references are supplied in boxes of 12 units with a minimum order of 30 boxes. If the procedure requires longer wound support, consider the polydioxanone (PDO, 180–210 days) or polyglecaprone PGCL (90–120 days) family; if a shorter absorption profile is needed, consider PGAR RAPID (40–45 days). Sterility and storage: product sterile by ethylene oxide and single-use; check the integrity of the pouch and the expiry date before each procedure, keep reference P128HR1740 together with the lot number for traceability in the operating theatre and store below 30 °C, protected from humidity and direct sunlight. For special B2B conditions by volume, hospital supply agreements or equivalence validation with other brands, contact the technical-commercial team at Cahnos.

Additional information

Manufacturer reference

P128HR1740

Material

100% synthetic absorbable polyglycolic acid (PGA)

Thread structure

Braided coated multifilament, fluted finish

Coating

Polycaprolactone and calcium stearate

USP size

4/0 (metric 1.5)

Approx. thread diameter

0.15 – 0.199 mm (USP/EP Pharmacopoeia)

Needle shape

½ circle (160°)

Needle body

Cylindrical

Needle tip

Taperpoint conical (atraumatic)

Needle size

HR 17 (17 mm)

Swaged

1 needle / 1 suture per unit

Absorption

Hydrolysis, complete between 60 and 90 days

Sterilisation

Ethylene oxide (EO); single-use, not re-sterilisable

Indications

Approximation of soft tissues, ligatures and general surgery

Presentation

Box of 12 units (individual sterile sachets)

Minimum order

30 boxes

Medida de aguja

HR 17

Usp

4/0

Color

Colourless

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Prime Suture | 100% Polyglycolic Acid | ½ Circle Cylindrical Body Taperpoint Conical Point HR17 Needle (17 mm) | USP Gauge 4/0 (Metric 1.5) | Colourless Thread 70 cm | Ref. P128HR1740 · Box of 12 units”

Your email address will not be published. Required fields are marked *