Description
1. Commercial Introduction
The absorbable multifilament polyglycolic acid (PGA) suture from the Prime range, reference P112HR2601 (SKU AMP112HR2601), is the absorbable closure solution your centre needs for general, digestive and gynaecological surgery procedures that require controlled absorption, excellent handling and impeccable knot security. It combines a 26 mm ½ circle needle with cylindrical body and taperpoint conical point with a 75 cm violet braided fluted thread in USP 1: a robust and highly versatile configuration for tissue approximation with moderate-to-high tension, ligatures and general surgery.
It is a synthetic, absorbable, sterile and single-use medical device, with an excellent quality-performance ratio for the B2B supply of operating theatres, clinics, purchasing centres and distributors of surgical material. Commercial presentation in a box of 12 units, with a minimum order of 30 boxes.
2. Technical explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish, coated with polycaprolactone and calcium stearate. This coating reduces friction when passing through tissues, improves thread sliding, regularises the surface of the strand and facilitates firm and secure knotting, with minimal tissue reaction.
Absorption occurs by hydrolysis, a predictable process independent of the patient’s enzymatic activity, which is completed within 60 to 90 days. Tensile strength retention maintains the necessary support during the first weeks of healing, while the tissue recovers its own resistance.
The HR 26 needle features a ½ circle curvature with cylindrical body and conical point (taperpoint geometry): an atraumatic point that passes through soft tissues and moderate densities with the least possible tearing, ideal for hollow organs, subcutaneous tissue, fascia and soft tissue in general. The fluted violet colour ensures optimal visibility on the surgical field. Product sterilised by ethylene oxide (EtO), single-use and non-reesterilizable.
3. Technical Specifications
3.1. Technical data sheet for reference P112HR2601
| Parameter | Specification |
|---|---|
| Factory reference | P112HR2601 (Prime range) |
| SKU Cahnos | AMP112HR2601 |
| Material | 100 % Polyglycolic Acid (PGA) synthetic absorbable |
| Coating | Polycaprolactone and calcium stearate |
| Thread structure | Braided multifilament with grooved finish |
| Gauge / size | USP 1 (metric 4), conforming to USP/EP Pharmacopoeia |
| Thread colour | Fluted violet (colourless version available in the range) |
| Thread length | 75 cm, 1 needle per thread |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint) |
| Needle size | HR 26 mm (26 mm) |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Commercial presentation | Box of 12 units; minimum order of 30 boxes |
3.2. Tensile strength retention profile after implantation
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60-90 days, by hydrolysis |
Complete absorption by hydrolysis within 60 to 90 days, with minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable and controlled absorption rate.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 1 (this product) | 4 | 0.40 – 0.499 mm (indicative) |
| 0 | 3.5 | 0.35 – 0.399 mm (indicative) |
| 2/0 | 3 | 0.30 – 0.339 mm (indicative) |
4. Equivalences and Cross-References
Coated braided multifilament polyglycolic acid (PGA) is the most widely used medium-duration synthetic absorbable in the surgical market, with an absorption profile of 60 to 90 days and a coating of polycaprolactone and calcium stearate. There is no equivalence table validated by the manufacturer for this specific configuration (PGA Prime, ½ circle HR 26 mm needle with conical point, USP 1 gauge, 75 cm violet thread); consult the technical department before use in tenders.
As homologous market families to be verified reference by reference in their official data sheet before substitution, the following lines are cited: 100% coated braided PGA —Safil (B. Braun), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH), Assucryl (Assut), Atramat PGA (Internacional Farmacéutica) and Resorba PGA— and polyglactin 910 lines —Vicryl / Vicryl Plus (Ethicon), Polysorb (Medtronic) and Novosyn (B. Braun)—, always checking USP 1 gauge, 26 mm needle size in ½ circle, conical point, 75 cm thread length and violet colour. The copolymer polyglactin 910 (PGLA) ranges are chemically different from PGA homopolymer (absorption of 56 to 72 days versus 60-90 days) and should not be treated as 1:1 interchangeable without validation from the pharmacy service or technical department. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
USP 1 gauge (metric 4) is indicated for tissues with moderate-to-high tension: fascia, aponeurosis, abdominal wall, deep subcutaneous tissue and ligatures of medium-calibre vessels. The HR 26 ½ circle conical point needle is the atraumatic choice for soft tissues and hollow organs; if firm penetration in fibrous tissues is required, consider the trocar point (HRT) or reverse cutting (HS) versions of the same PGA family.
| Reference | Variant of interest |
|---|---|
| AMP112HR2601 (P112HR2601) | PGA Prime, HR26 conical point needle, USP 1, violet, 75 cm (current product) |
| AMP112HR2610 (P112HR2610) | PGA Prime, same HR26 needle, USP 0, violet, 75 cm (immediately lower gauge) |
| AMP112HR2630 (P112HR2630) | PGA Prime, same HR26 needle, USP 3/0, violet, 75 cm (fine gauge for delicate tissues) |
| AMP118HR2640 (P118HR2640) | PGA Prime, same HR26 needle, USP 4/0, violet, 70 cm (precision in lax tissues) |
| AMP112HS2601 (P112HS2601) | PGA Prime, HS26 needle triangular reverse cutting point, USP 1, violet, 75 cm (firm tissues) |
| AMP112HRT2630 | PGA Prime, HRT26 needle trocar point (tapercut), USP 3/0, violet, 75 cm (moderate tension tissues) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, keep the reference together with the batch number for traceability in the operating theatre and store in a cool, dry place, protected from sunlight. For B2B volume conditions or enquiries about additional gauges, lengths and colours, contact the technical-commercial team at Cahnos.