Description
1. Commercial Introduction
At Cahnos we offer you the absorbable multifilament suture of polyglycolic acid (PGA) from the Prime range, reference AMP112HR2020. It is the professional choice for general surgery departments and procedures requiring secure closure, excellent thread handling and fully controlled reabsorption. It combines a ½ circle needle with cylindrical body and Taperpoint conical tip of 20 mm (HR 20), a ribbed violet thread of 75 cm in USP gauge 2/0 and a B2B presentation in a box of 12 units, designed for hospital supply, clinics, purchasing centres and tenders. A synthetic, sterile, single-use medical device with an excellent quality-price ratio for the continuous supply of your centre.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic homopolymer presented in a braided multifilament structure with a ribbed finish and a coating of polycaprolactone and calcium stearate. This architecture regularises the thread surface, reduces friction when passing through tissues, minimises the sawing effect, improves sliding and guarantees firm, secure knot tying even in medium working gauges such as USP 2/0. Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity, completed between 60 and 90 days: the thread maintains tensile support during the first 2 to 4 weeks of healing while the tissue recovers its own resistance. The HR 20 needle, ½ circle with cylindrical body and Taperpoint conical tip, penetrates by separating the fibres without a cutting effect, making it especially atraumatic for soft and friable tissues, ligatures and tissue approximation in general surgery. The ribbed violet colour ensures optimal visibility on the surgical field. Product sterile by ethylene oxide, single-use and not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference AMP112HR2020
| Parameter | Specification |
| Reference (SKU Cahnos) | AMP112HR2020 |
| Range / Quality | Prime (PGA range) |
| Thread material | 100% polyglycolic acid (PGA), absorbable homopolymer |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 2/0 (metric 3), in accordance with USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.30–0.349 mm (indicative according to Pharmacopoeia) |
| Thread colour | Violet (grooved) |
| Thread length | 75 cm (1 needle per suture) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Needle tip | Conical Taperpoint, atraumatic |
| Needle size | HR 20 (20 mm) |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 40 % of initial tensile strength |
| Total absorption | 60–90 days, by hydrolysis (predictable rate) |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying. Absorption range and retention values copied literally from the manufacturer’s documentation, without extension of limits.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 (this product) | 3 | 0.30 – 0.349 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
The thread diameter complies with the official USP/EP Pharmacopoeia ranges for synthetic absorbable sutures, without extending their limits.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is the most well-established medium-duration absorbable braided multifilament on the market and shares an absorption profile (60–90 days), a braided structure coated with polycaprolactone and calcium stearate, and clinical behaviour with homologous families in the sector. There is no equivalence table validated by the manufacturer that cross-references this specific product (100% PGA, HR 20 conical-tip needle, USP 2/0, violet, 75 cm) with other brands in exact configuration; the following matches are functional comparisons at category level and should not be treated as 1:1 interchangeable without prior technical validation.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| SMI (Belgium) | Surgicryl PGA – coated braided multifilament, violet, HR conical-tip ½ circle needle | SM1130 0126 (HR 26 mm, USP 2/0, 75 cm) | Comparable by category (not interchangeable 1:1) | Code verified in authorised distribution sources: same PGA polymer, same coating (polycaprolactone and calcium stearate), USP gauge 2/0 and 75 cm length. The needle size differs (26 mm vs. HR 20 of 20 mm); confirm geometry and packaging before substituting. |
| B. Braun | Safil Violet – coated PGA multifilament, violet | G1038406 (SAFIL VIOLET 2/0 (3) 2X70CM) | Comparable by category (not interchangeable 1:1) | Reference verified in the AccessGUDID regulatory database: same PGA material and USP gauge 2/0 (metric 3), violet colour. The length differs (70 cm vs. 75 cm), the coating type (polyglyconate vs. polycaprolactone and calcium stearate) and no needle is specified in the registration; consult the IFU before substituting. |
As homologous ranges in the 100% PGA coated braided medium-absorption segment, to be verified reference by reference in their official data sheet before substitution, the following lines are cited: Dexter / Dexon II (Medtronic-Covidien), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH), Atramat (Resorba) and the polyglactin 910 lines —Coated VICRYL (Ethicon), Safil (B. Braun), Polysorb (Medtronic)— which, being chemically different from PGA homopolymer (PGLA 90/10 copolymer, absorption 56–72 days), should not be treated as 1:1 interchangeable without validation from the pharmacy service or the technical department.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The cited brands belong to their respective manufacturers and are mentioned solely as comparative reference.
5. Selection tips and variants of interest
USP gauge 2/0 (metric 3) offers an optimal balance between strength and fineness, indicated for soft tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligatures of medium-calibre vessels. The HR 20 needle, ½ circle with Taperpoint conical tip, is atraumatic and suitable for delicate tissues and superficial planes; if you need to reach deeper planes or firmer tissues, consider needles with a larger radius (HR 26, HR 30) or trocar points (HRT) and reverse cutting points (HS) available in the same range. Within the Cahnos catalogue, the same configuration is available in standard quality under reference AM112HR2020, and in polyglactin 910 (PGLA) under references 1L12HR2020 and P1L12HR2020 if you prefer a shorter absorption window (56–72 days).
| Reference / Variant | Description |
| AMP112HR2020 | PGA Prime – HR20 conical tip – USP 2/0 violet – 75 cm (this product) |
| AM112HR2020 | Standard PGA – HR20 conical tip – USP 2/0 violet – 75 cm (economical alternative, same geometry) |
| AMP112HR2030 | PGA Prime – HR20 – USP 3/0 violet – 75 cm (fine gauge) |
| AMP112HR2040 | PGA Prime – HR20 – USP 4/0 violet – 75 cm (very fine gauge) |
| AMP112HR2220 | PGA Prime – HR22 – USP 2/0 violet – 75 cm (slightly larger needle) |
| AMP112HR2620 | PGA Prime – HR26 – USP 2/0 violet – 75 cm (medium-depth planes) |
| P1L12HR2020 | PGLA Prime – HR20 – USP 2/0 violet – 75 cm (absorption 56–72 days) |
The violet colour offers maximum visibility in the surgical field; if aesthetic discretion is required in superficial areas, request the same configuration in colourless thread on demand. As this is a sterile single-use product, always check the integrity of the pouch and the expiry date before each procedure, keep the reference together with the batch number for traceability in the operating theatre and store in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or validation of equivalences for tenders, contact the technical-commercial team of Cahnos.





Reviews