Description
1. Commercial Introduction
The absorbable multifilament PGA Prime suture, reference P118HR4010 (SKU AMP118HR4010), is the reference choice in the operating theatre for hospitals, private clinics, purchasing groups and tenders that demand a high-performance absorbable synthetic thread with excellent value for money. This presentation combines an atraumatic half-circle needle with a cylindrical body and a 40 mm Taperpoint conical point (HR 40), USP 0 gauge (metric 3.5) and a 70 cm violet grooved thread, ensuring precision, handling and fully predictable absorption during the first weeks of healing.
Each unit is supplied sterile and ready to use, in a box of 12 units with batch traceability and special conditions for the B2B channel (minimum order of 30 units).
2. Technical Explanation
Polyglycolic acid (PGA) is a 100 % absorbable synthetic polymer presented in a braided multifilament structure with a grooved finish and coated with polycaprolactone and calcium stearate. This configuration reduces friction when passing through tissue, minimises the sawing effect, offers very smooth handling and ensures firm, secure knot tying, even in medium-diameter gauges such as USP 0.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity. The thread retains 75 % of its tensile strength at 2 weeks, 50 % at 3 and 40 % at 4, an ideal profile for tissues requiring mechanical support during 2 to 4 weeks of healing.
The half-circle needle with cylindrical body and conical point (Taperpoint geometry) penetrates by separating the fibres without cutting them, minimising trauma to soft tissues; the violet colour ensures optimal visibility of the thread in the surgical field. Product sterilised by ethylene oxide (EO), single-use and non-reesterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference P118HR4010
| Characteristic | Specification |
|---|---|
| Reference (SKU Cahnos) | AMP118HR4010 |
| Factory / line reference | P118HR4010 |
| Range / Quality | Prime (premium multifilament range) |
| Material | 100% polyglycolic acid (PGA), absorbable by hydrolysis |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 0 (metric 3.5); approximate diameter 0.35 – 0.399 mm (USP/EP) |
| Thread colour | Violet (also available colourless in the family) |
| Thread length | 70 cm (1 thread, 1 needle) |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | 40 mm (HR 40 Prime) |
| Absorption mechanism | By hydrolysis |
| Absorption period | 60 – 90 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and general surgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Minimum order | 30 units |
| Regulatory standard | Compliant with USP / European Pharmacopoeia (EP); CE marking (MDR) |
3.2. Tensile strength retention profile after implantation
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75% of initial strength |
| 3 weeks | 50% of initial strength |
| 4 weeks | 40% of initial strength |
| Total absorption | 60 – 90 days, by hydrolysis |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.349 mm |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
| 2 | 5 | 0.50 – 0.599 mm |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) braided multifilament coated with medium absorption (60-90 days) is the classic ‘Dexon’ type family, one of the most well-established synthetic absorbables in surgical practice. For the specific configuration of this data sheet (PGA homopolymer, half-circle needle HR 40 mm with Taperpoint conical point, USP 0 gauge, violet thread 70 cm, single needle), the following homologous reference verified against the regulatory base has been compared:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun | Safil Violet, coated multifilament PGA | GUDID 04038653963539 – Ref. X1048556 (SAFIL VIOLET 0 (3.5) 90CM HR40S) | Comparable by category (not interchangeable 1:1) | Same material (PGA 100 %), USP 0 gauge (metric 3.5), half-circle curvature, atraumatic conical point and 40 mm needle (HR40S); they differ in thread length (90 cm vs. 70 cm) and coating type (polyglyconate vs. polycaprolactone and calcium stearate). Reference verified in GUDID; consult IFU before substitution. |
At category level, they are also homologous lines of 100 % braided coated PGA to be verified reference by reference in their official data sheet before any substitution: Surgicryl® PGA (SMI), Dexon® / Dexon II® (Medtronic/Covidien), DemeSORB® PGA (DemeTECH), AssuCryl® PGA (Assut), Atramat® (Laboratorio Aragó) and SERAFIT (Serag Wiessner), always checking the USP 0 gauge, half-circle curvature, 40 mm conical point, 70 cm thread length and violet colour. The copolymeric ranges of polyglactin 910 (Coated VICRYL® from Ethicon, Polysorb® from Medtronic, Novosyn® from B. Braun) share the clinical category of absorbable braided suture with medium absorption but are chemically different from PGA homopolymer (absorption 56-72 days vs. 60-90 days) and should not be treated as 1:1 interchangeable without technical validation.
There is no manufacturer-validated equivalence table that cross-references this specific configuration (PGA Prime multifilament, HR 40 mm needle, USP 0 gauge, violet thread 70 cm, ref. P118HR4010) with exact codes from other commercial houses; the matches identified should be treated as functional category comparisons and not as 1:1 interchangeable. Consult the technical department of Cahnos before using in tenders or direct substitution.
5. Selection tips and variants of interest
The USP 0 (metric 3.5) gauge is very versatile: it is indicated for medium-thickness tissues requiring good initial strength —muscle planes, aponeuroses, fascia, deep subcutaneous tissue, wall closures and ligation of medium-calibre vessels in general, digestive and gynaecological surgery—. The half-circle needle with Taperpoint conical point separates the fibres without cutting them, being the most atraumatic option for soft and friable tissues; if the tissue is very delicate, the blunt point (HRN) is recommended, while for fibrous and dense structures the trocar point (HRT) is considered.
Within the Cahnos catalogue, the following variants of interest are available:
| Reference | Variant of interest |
|---|---|
| AMP118HR4010 | PGA Prime USP 0, conical needle HR 40 mm, violet, 70 cm (current product) |
| AM118HR4010 | PGA Normal quality USP 0, same HR 40 mm needle, violet, 70 cm (standard range alternative) |
| AMP113HR4010 | PGA Prime USP 0, conical needle HR 40 mm, violet, 90 cm (longer thread length) |
| AMP118HR4030 | PGA Prime USP 3/0, same HR 40 mm needle, violet, 70 cm (finer gauge) |
| AMP118HR4001 / AMP118HR4002 | PGA Prime USP 1 and USP 2, same HR 40 mm needle, violet, 70 cm (higher strength) |
| P1L18HR4010 | PGLA (Polyglactin 910) Prime USP 0, same HR 40 mm needle, violet, 70 cm (absorption 56-72 days) |
| AMP118HS4010 | PGA Prime USP 0, triangular reverse cutting needle HS 40 mm, violet, 70 cm (firm tissues) |
If the protocol requires longer strength retention (180-210 days), consider the polydioxanone (PDO) family. As it is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, keep the reference together with the batch number for traceability in the operating theatre and store in a cool, dry place, protected from sunlight. For B2B volume conditions, hospital supply contracts or validation of equivalences from other commercial brands, contact the technical-commercial team at Cahnos.