We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Prime Suture 1/2 Circle Conical Point Taperpoint HR45 (45 mm) – USP 2 – Violet Grooved 90 cm – Box of 12 units

Original price was: 46,29 €.Current price is: 32,60 €.

Absorbable multifilament suture of polyglycolic acid (PGA) in Prime quality, mounted on a ½ circular needle with cylindrical body and conical Taperpoint point of 45 mm (HR45). USP 2 gauge (metric 5), violet grooved thread of 90 cm with polycaprolactone and calcium stearate coating. Predictable absorption by hydrolysis in 60–90 days, with tensile strength retention of 75 % at 2 weeks, 50 % at 3 and 40 % at 4. Sterile by ethylene oxide, single-use and minimal tissue reaction; indicated for tissue approximation, ligatures and general surgery. Reference AMP113HR4502, presentation in a box of 12 units with B2B conditions.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP113HR4502

Description

1. Product Presentation

The absorbable multifilament suture of polyglycolic acid (PGA) in Prime quality is the reference surgical closure solution for operating theatres, clinics and purchasing centres that demand fully predictable behaviour, excellent tensile strength and great security in knot tying. This presentation in USP 2 gauge mounts a ½ circle needle, cylindrical body and conical Taperpoint point of 45 mm (HR45), with a violet grooved thread of 90 cm.

It is supplied sterile and ready to use, in a box of 12 units with batch traceability, in a B2B format oriented to hospital replenishment, tenders and public competitions. Reference AMP113HR4502.

2. Technical explanation of the material and procedure

Polyglycolic acid (PGA) is a synthetic absorbable homopolymer presented in a braided and grooved multifilament structure, coated with polycaprolactone and calcium stearate. This configuration provides great flexibility, low shape memory and a contained friction coefficient, which favours the sliding of the thread through the tissue, very smooth handling and a firm and secure knot, even in high-diameter gauges such as USP 2.

Absorption occurs by hydrolysis, a uniform mechanism independent of the patient’s enzymatic activity, with total absorption between 60 and 90 days and minimal tissue reaction. During the first weeks of healing, the thread maintains the necessary tensile strength while the tissue recovers its own strength.

The ½ circle needle with cylindrical body and conical point (Taperpoint geometry) of 45 mm separates the fibres without cutting effect: it is the most atraumatic configuration for delicate and friable tissues, with controlled passage and minimal injury along the penetration path. The violet grooved colour guarantees optimal visibility over the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.

3. Technical Specifications

Parameter Specification
Reference (SKU) AMP113HR4502
Range / quality PGA Prime
Suture type Absorbable synthetic multifilament
Composition 100 % polyglycolic acid (PGA)
Coating Polycaprolactone and calcium stearate
Thread structure Braided multifilament, grooved
Gauge USP 2 (metric 5)
Thread diameter 0.45 – 0.499 mm (indicative USP/EP standard)
Thread colour Violet grooved
Thread length 90 cm
Needle shape ½ circle
Needle body Cylindrical
Needle tip Conical Taperpoint, atraumatic
Needle size 45 mm (HR45), 1 needle per thread
Absorption mechanism Hydrolysis
Total absorption 60 – 90 days
Sterilisation Ethylene oxide (EO), sterile, single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units
Minimum order 30 boxes
Regulatory standard USP / European Pharmacopoeia (EP)

Tensile strength retention profile:

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 40 % of initial tensile strength
Total absorption 60 – 90 days, by hydrolysis

4. Equivalences and Cross-References

Braided coated polyglycolic acid (PGA) is the most well-established absorbable multifilament raw material of medium absorption in surgical practice (classic family type ‘Dexon’). This Prime reference, with hydrolysis absorption of 60–90 days and tensile strength retention of 75/50/40 % at 2/3/4 weeks, shares polymer, coating (polycaprolactone and calcium stearate) and clinical profile with the homologous PGA lines on the market: B. Braun Safil® (braided coated PGA), SMI Surgicryl® PGA, DemeTECH DemeSORB® PGA, Assut AssuCryl® PGA and the historical Medtronic Dexon®/Dexon II® range. The polyglactin 910 (PGLA) ranges, such as Ethicon Vicryl® or Medtronic Polysorb®, share the absorbable multifilament category but differ in chemical composition and absorption profile (56–72 days).

There is no equivalence table validated by the manufacturer for this specific configuration (PGA multifilament Prime, ½ circle conical Taperpoint HR45 needle of 45 mm, USP 2 gauge, violet thread of 90 cm) against the cited commercial houses; consult the technical department before using in a tender. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (45 mm), ½ curvature, point family (conical), mounting (single needle), thread length (90 cm) and colour.

5. Selection tips and variants of interest

USP 2 gauge (metric 5) is indicated for tissues requiring high initial strength: aponeurosis, fascia, muscle planes, abdominal wall closures and ligatures of medium-large calibre vessels. The conical Taperpoint needle separates the fibres without cutting them, being the most atraumatic option for soft and friable tissues; if the plane to be sutured is firm and not very compliant, consider the trocar points (Tapercut) from the same range.

Within the Cahnos catalogue, the following variants of interest are available:

  • AMP113HR4802: same PGA Prime family, USP 2, violet, 90 cm, with conical HR48 needle of 48 mm (larger needle size).
  • AMP118HR4001: PGA Prime USP 1, conical HR40 needle of 40 mm, violet, 70 cm (lower gauge and shorter length).
  • AM113HR4502: same configuration (HR45, USP 2, violet, 90 cm) in standard quality, for cost optimisation.

All references are supplied in a box of 12 units; the minimum order is 30 boxes. As it is sterile single-use material, check the integrity of the packaging and the expiry date before each procedure and keep the reference and batch for traceability in the operating theatre. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial houses, contact our technical-commercial team.

Additional information

Suture type

Absorbable synthetic multifilament

Material

100 % polyglycolic acid (PGA)

Coating

Polycaprolactone and calcium stearate

Thread structure

Braided multifilament, grooved

USP size

2 (metric 5)

Thread diameter

0.45 – 0.499 mm (indicative USP/EP)

Thread colour

Violet grooved

Needle body

Cylindrical

Needle tip

Conical Taperpoint, atraumatic

Needle size

45 mm (HR45)

Swaged

1 needle per suture

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Regulatory standard

USP / European Pharmacopoeia (EP)

Medida de aguja

HR 45

Usp

2

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Prime Suture 1/2 Circle Conical Point Taperpoint HR45 (45 mm) – USP 2 – Violet Grooved 90 cm – Box of 12 units”

Your email address will not be published. Required fields are marked *