Description
1. Commercial Introduction
The Prime Heavy multifilament PGA absorbable suture, reference AMP112HR4002H, is the benchmark surgical closure solution for hospitals, general surgery operating theatres, private clinics and B2B purchasing centres seeking a high-performance absorbable synthetic thread with an excellent price-quality ratio. This presentation combines a ½ circle needle with a cylindrical body and taper point (Taperpoint) of 40 mm (HR 40), USP 2 gauge and a 75 cm fluted violet thread.
Each unit is supplied sterile and ready to use, with the guarantee of professional distribution from Cahnos. Its Prime Heavy design ensures superior performance in procedures requiring high safety and reliability: tissue approximation, ligatures, deep planes and general surgery.
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, very smooth handling, low memory and firm, secure knot tying, even in larger diameter gauges such as USP 2.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days, independent of the patient’s enzymatic activity. The thread retains 75% of its tensile strength at 2 weeks, 50% at 3 and 40% at 4, an ideal profile for tissues requiring support during 2 to 4 weeks of healing.
The ½ circle needle with cylindrical body and taper point (Taperpoint) penetrates by separating the fibres without cutting them, minimising trauma to soft tissues; the fluted violet colouration ensures optimal visibility of the thread on the surgical field. Sterilisation by ethylene oxide; sterile single-use product, with no possibility of re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet
| Characteristic | Specification |
| Reference (SKU Cahnos) | AMP112HR4002H |
| Range / Quality | PREMISUT, Prime Heavy quality |
| Material | 100% Polyglycolic acid (PGA) with polycaprolactone and calcium stearate coating |
| Thread structure | Braided multifilament with grooved finish |
| Colour | Violet (also available colourless) |
| Gauge | USP 2 (metric 5) |
| Thread length | 75 cm (1 strand) |
| Needle shape | ½ circle (1/2) |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint) |
| Needle size | 40 mm (HR 40 Heavy Prime) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60–90 days |
| Sterilisation | Ethylene oxide (EO), single-use, not for re-sterilisation |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
| Total absorption | 60–90 days, by hydrolysis |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate.
3.3. Presentation and ordering conditions
| Value | Value |
| Presentation | Box of 12 units (individual sterile unit) |
| Minimum order | 30 units |
| Format | Sterile, single-use |
4. Equivalences and Cross-References
The polyglycolic acid (PGA) suture belongs to the family of braided synthetic absorbable sutures with medium absorption. By polymer composition (PGA homopolymer), braided structure, coating, hydrolysis absorption profile (60–90 days) and tensile retention, it is comparable at category level (not 1:1 interchangeable) with international market lines: Ethicon (Johnson & Johnson) with its Coated VICRYL / VICRYL Plus range (coated braided polyglactin 910, violet; differs in PGLA 90/10 copolymer material versus PGA homopolymer and in absorption window of 56–72 days), B. Braun with Safil (braided violet PGLA), Medtronic / Covidien with Polysorb, SMI with Surgicryl, Assut with Assucryl 910 and Laboratorio Aragó (½ circle cylindrical HR/TC needle series).
There is no manufacturer-validated equivalence table cross-referencing these brands for the configuration of taper needle HR 40 mm, USP 2 gauge and 75 cm thread; the cited lines are provided as a functional category comparison and must be verified field by field (gauge, thread length, needle radius and coating) before any formal substitution in tenders. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.
5. Selection tips and variants of interest
USP 2 gauge (metric 5) is indicated for tissues requiring greater initial strength: deep planes, fascia, aponeurosis, high-tension closures and ligatures. The taper point (Taperpoint) separates the fibres without cutting them, ideal for soft and friable tissues; if the tissue is very delicate, the most atraumatic option is the blunt point, while for fibrous and dense structures the trocar point is recommended.
Check the needle radius (HR 40, 45 or 48 mm) according to the depth and surgical area to be treated. Within the PGA Prime family from Cahnos, variants of this configuration are offered: AMP112HR4802H (USP 2 with HR 48 mm needle), AMP112HR4001H (USP 1 with HR 40 mm needle), AM112HR4002H (Normal quality with the same HR 40 mm needle) and AMP112HR4820 (USP 2/0 gauge). If you prefer a polyglactin 910 alternative with an absorption window of 56–72 days, see references P1L12HR4002H and 1L12HR4002H. For longer strength retention needs (180–210 days), the polydioxanone (PDO) family is the recommended alternative.
As a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. Consult our technical-commercial team for special volume conditions: minimum order of 30 units, with scheduled deliveries for hospitals, clinics and purchasing centres.





Reviews