Description
1. Commercial Introduction
The absorbable multifilament suture of polyglycolic acid (PGA) from the Premisut range, reference 113HR4810 (SKU AM113HR4810), is the reference surgical closure solution for hospitals, private clinics, purchasing groups and wholesalers seeking a high-performance absorbable synthetic thread with an excellent quality-price ratio in B2B procurement and tenders.
It incorporates a ½ circle needle with cylindrical body and conical point (taperpoint) of 48 mm, USP 0 gauge (metric 3.5) and a 90 cm violet fluted thread coated with polycaprolactone and calcium stearate: a combination designed for approximation of soft tissues, ligatures and general surgery. Each unit is supplied sterile by ethylene oxide and ready to use, in individual sachets with batch traceability.
2. Technical explanation of the product and procedure
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration facilitates the passage of the thread through tissue, reduces friction and the sawing effect, offers very smooth handling and guarantees firm and secure knot tying, even in medium working gauges such as USP 0.
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance that the body metabolises without generating relevant tissue reaction. The tensile strength retention profile maintains the necessary support during the critical healing phase (75% at 2 weeks, 50% at 3 and 40% at 4).
The ½ circle needle with cylindrical body and conical point (taperpoint) penetrates by separating the fibres without cutting them, minimising trauma to soft and friable tissues; the violet colouring ensures optimal visibility on the surgical field. Single-use product, with no possibility of re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference 113HR4810
| Factory reference | 113HR4810 |
| Reference (SKU Cahnos) | AM113HR4810 |
| Range / Quality | PREMISUT – Normal quality |
| Thread material | 100 % polyglycolic acid (PGA), synthetic absorbable |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 0 (metric 3.5 – EP) |
| Thread colour | Violet grooved |
| Thread length | 90 cm (1 thread) |
| Needle shape | ½ circle (approx. 180°) |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | 48 mm (HR 48), 1 needle per thread |
| Absorption mechanism | Hydrolysis (60-90 days) |
| Sterilisation | Ethylene oxide (EO); single-use, non-reesterilizable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 sterile units (individual pouches) |
| Regulatory standard | Conforms to USP/EP Pharmacopoeia for synthetic absorbable sutures |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 2 weeks | 75% of initial strength |
| 3 weeks | 50% of initial strength |
| 4 weeks | 40% of initial strength |
| Complete absorption | 60-90 days by hydrolysis |
Predictable absorption by hydrolysis with minimal tissue reaction, excellent tensile strength and optimal knot tying, in accordance with USP / European Pharmacopoeia. Absorption range and retention values copied literally from the manufacturer’s documentation, without extension of limits.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 2/0 | 3 | 0.30 – 0.349 mm |
| 0 (this product) | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
| 2 | 5 | 0.50 – 0.599 mm |
The thread diameter complies with the official USP Pharmacopoeia ranges for synthetic absorbable sutures, without extending their limits.
4. Equivalences and Cross-References
Coated braided multifilament polyglycolic acid (PGA) with medium absorption (60-90 days) is one of the most widely used synthetic absorbables in general surgery and ligatures. The specific configuration of this data sheet —PGA homopolymer, ½ circle HR 48 mm needle with conical point (taperpoint), USP 0 gauge, 90 cm violet thread— has been compared with the main homologous families on the market. The closest external references located and verified in terms of needle geometry, length, colour and coated braided structure are the following:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® (polyglactin 910, coated braided multifilament, violet, CTX needle conical point 48 mm, ½ circle, 90 cm) | J371H | Comparable by category (not interchangeable 1:1) | They match in 90 cm length, violet colour, ½ circle 48 mm needle with conical point and coated braided structure. They differ in gauge (USP 1 vs USP 0), polymer (polyglactin 910 copolymer vs PGA homopolymer) and absorption window (56-70 days vs 60-90 days). Code verified in the manufacturer’s product centre and authorised distribution. |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® Plus Antibacterial (polyglactin 910, antibacterial coated braided, violet, CTX needle conical point 48 mm, ½ circle, 90 cm) | VCP371H | Comparable by category (not interchangeable 1:1) | They match in 90 cm length, violet colour, ½ circle 48 mm needle with conical point and coated braided structure. They differ in gauge (USP 1 vs USP 0), polymer (PGLA 910) and the antibacterial coating (triclosan) absent in PGA. Code verified in the manufacturer’s product centre and authorised distribution. |
Other commercial houses with homologous families of medium-absorption braided absorbable suture —B. Braun with the Safil® line (coated braided PGA), Medtronic with the braided polyglactin 910 range such as Polysorb and SMI with Surgicryl® PGA— offer products of the same clinical category, but no confirmed code has been found in official sources for the exact configuration USP 0 + HR 48 mm conical point needle + 90 cm thread + violet.
There is no manufacturer-validated equivalence table cross-referencing this specific reference with closed codes from other brands; consult the technical department before using in a tender. Before substituting this reference in a specification, check one by one: material, USP gauge, needle size (48 mm), ½ curvature, point family (conical/taperpoint), thread length (90 cm) and colour. The brands cited belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues and closures requiring a balance between initial strength and delicacy, with healing support of 2 to 4 weeks. The conical point (HR) separates the fibres without cutting them and is ideal for soft tissues; if the tissue is very friable, the most atraumatic option is the blunt point (HRN), while for firm and dense tissues the reverse cutting triangular point (HS) or the trocar point (HRT) is recommended.
| Reference (SKU) | Variant of interest |
| AM113HR4810 | PGA USP 0, HR 48 mm conical needle taperpoint, violet, 90 cm (current product) |
| AM113HR4801 | PGA USP 1, same HR 48 mm needle, violet, 90 cm (larger gauge) |
| AM113HR4802 | PGA USP 2, same HR 48 mm needle, violet, 90 cm (higher strength) |
| AM112HR4810 | PGA USP 0, HR 48 mm conical needle, violet, 75 cm (shorter thread) |
| AMP113HR4810 | Prime-quality PGA USP 0, HR 48 mm conical needle, violet, 90 cm |
| AM113HS4810 | PGA USP 0, HS 48 mm reverse cutting triangular needle, violet, 90 cm (dense tissues) |
| 1L13HR4810 | Polyglactin 910 USP 0, HR 48 mm conical needle, violet, 90 cm (absorption 56-72 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare facility. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For longer strength retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. For special B2B conditions, volume orders or confirmation of equivalences for tenders, contact our technical-commercial team.





Reviews