Description
1. Commercial Introduction
The Absorbable Multifilament PGA Suture factory reference 113HR3640 (SKU AM113HR3640) is the surgical closure solution your centre needs for general surgery and ambulatory surgery procedures that require controlled reabsorption, excellent handling and impeccable knot security. It combines a ½ circle cylindrical body needle with a conical (taperpoint) point of 36 mm with a braided 100% polyglycolic acid (PGA) thread in USP 4/0 gauge, violet grooved colour and 90 cm length.
Presented in B2B format in a box of 12 units (individual sterile sachets) with a minimum order of 30 boxes, it offers an outstanding price-quality ratio for operating theatres, clinics, distributors, purchasing centres and surgical material tenders.
2. Technical Explanation
Polyglycolic acid (PGA) is a 100% absorbable synthetic polymer that is presented in a braided multifilament structure with a grooved finish, coated with polycaprolactone and calcium stearate. This coating regularises the surface of the thread, reduces friction when passing through tissues, improves sliding and facilitates firm and secure knotting, with minimal tissue reaction.
Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity, completed between 60 and 90 days. The thread maintains the necessary tensile support during the first 2 to 4 weeks of healing, while the tissue recovers its own resistance. The HR 36 ½ circle needle with conical (taperpoint) point penetrates by separating the fibres without cutting them, minimising trauma to delicate structures; it is therefore especially indicated for approximation of soft tissues, ligatures and general surgery. The violet colour guarantees optimal visibility on the surgical field. Product sterile by ethylene oxide (EtO), single-use and not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference AM113HR3640 (113HR3640)
| Characteristic | Specification |
|---|---|
| Reference (SKU Cahnos) | AM113HR3640 |
| Factory reference | 113HR3640 (nomenclature Premisut) |
| Composition | 100% polyglycolic acid (PGA), absorbable homopolymer |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge / size | USP 4/0 (metric 1.5), conforming to USP/EP Pharmacopoeia |
| Approximate thread diameter | 0.15 – 0.199 mm |
| Thread colour | Violet (grooved); colourless version available in the family |
| Thread length | 90 cm |
| Needle shape | ½ circle (1/2 circular) |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | HR 36 (36 mm), 1 needle per thread |
| Absorption mechanism | Hydrolysis, completed between 60 and 90 days |
| Sterilisation | Ethylene oxide (EtO); sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 40% of initial tensile strength |
| Total absorption | 60-90 days, by hydrolysis (predictable rate) |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.
3.3. Gauge equivalence according to USP/EP Pharmacopoeia
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 4/0 (this product) | 1.5 | 0.15 – 0.199 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
The thread diameter complies with the official ranges of the USP/EP Pharmacopoeia for synthetic absorbable sutures, without exceeding its limits.
3.4. Decoding of the official reference
The official reference 113HR3640 is decoded as: 113 (violet thread series of 90 cm) + HR36 (½ circle cylindrical body needle with 36 mm taperpoint conical point) + 40 (USP 4/0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is the most well-established medium-duration braided multifilament absorbable on the market and shares an absorption profile (60-90 days), coated braided structure and clinical behaviour with homologous families in the sector. There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the match cited below is a catalogue comparison verified against authorised distribution and is not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL® – braided coated polyglactin 910, violet | J337H – USP 4-0, CT-1 taper point needle of 36 mm, ½ circle, 27″ (≈69 cm) | Comparable by category (not interchangeable 1:1) | Code verified in authorised distribution: USP 4/0 gauge, ½ circle curvature, 36 mm conical needle (CT-1 taper point) and violet colour match. Differences: thread length (27″ ≈ 69 cm vs 90 cm), polymer (polyglactin 910 vs 100% PGA), absorption profile (56-72 days vs 60-90 days) and presentation (box of 36 units vs 12 units). |
There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders. As homologous ranges in the medium-absorption coated braided PGA segment, the following appear: Dexon II (Medtronic/Covidien), Surgicryl PGA (SMI), DemeSORB PGA (DemeTECH), LUXCRYL PGA (Aston Medical) and Atramat (Resorba), as well as the polyglactin 910 lines Coated VICRYL® / VICRYL® Plus (Ethicon), Safil (B. Braun), Polysorb (Medtronic) and Novosyn (B. Braun), comparable by category, material and absorption profile; for the exact combination USP 4/0 / HR 36 mm conical point needle / 90 cm in violet, the specific codes of those houses must be confirmed with the manufacturer before any substitution, verifying material, gauge, curvature, needle type and size, thread length, colour and configuration. This geometry (HR36, USP 4/0, 90 cm, violet) is fully safely interchangeable only within the Cahnos reference system itself.
5. Selection tips and variants of interest
USP 4/0 gauge (metric 1.5) is indicated for soft and delicate tissues with low-medium tension: subcutaneous tissue, mucosa, intestinal wall, approximation of friable tissues and ligation of fine vessels. The HR36 ½ circle needle with conical (taperpoint) point is atraumatic and ideal for soft tissues; if you need to penetrate firmer and denser tissues (skin, sclera, aponeurosis), consider the reverse cutting (HS) or trocar (HRT) points available in the same range.
| Variant / Reference | Description |
|---|---|
| AM113HR3640 (113HR3640) | PGA – HR36 conical point – USP 4/0 violet – 90 cm (this product) |
| AM123HR3640 (123HR3640) | PGA – HR36 conical point – USP 4/0 colourless – 90 cm (same geometry, maximum discretion) |
| AMP113HR3640 (P113HR3640) | PGA Prime – HR36 conical point – USP 4/0 violet – 90 cm (superior quality) |
| AM113HR3630 (113HR3630) | PGA – HR36 conical point – USP 3/0 violet – 90 cm (immediately higher gauge) |
| AM113HR3620 (113HR3620) | PGA – HR36 conical point – USP 2/0 violet – 90 cm (larger gauge and strength) |
| 1L13HR3640 | PGLA polyglactin 910 – HR36 taper point – USP 4/0 violet – 90 cm (absorption 56-72 days) |
All references are supplied in boxes of 12 units with a minimum order of 30 boxes to ensure continuous supply for your healthcare facility. If you require longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the pouch and the expiry date before each procedure, keep the reference alongside the batch number for traceability in the operating theatre, and store in a cool, dry place, protected from sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team of Cahnos.





Reviews