Description
1. Introduction
The absorbable multifilament PGA suture from the PREMISUT range is the reference solution in the operating theatre for the professional seeking a synthetic absorbable thread with reliable, predictable performance and excellent value for money in B2B procurement. Its ½ circle needle with reverse cutting triangular point of 48 mm (HS48) ensures firm and controlled penetration even in dense tissues, while the grooved violet thread of 90 cm offers optimal visibility on the surgical field and excellent handling in every stitch.
It is a sterile, single-use medical device with minimal tissue reaction, excellent tensile strength and optimal knot security. Commercial presentation in a box of 12 units and a minimum order of 30 boxes, ideal for the continuous supply of hospitals, clinics and purchasing centres.
2. Technical Explanation
Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a grooved finish. Its coating of polycaprolactone and calcium stearate improves the sliding of the thread through tissue, reduces friction and facilitates firm and secure knot tying, even in medium-diameter gauges such as USP 1 (metric 4).
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days and independent of the patient’s enzymatic activity. This profile makes the suture suitable for tissues that require wound support during the first weeks of healing. The ½ circle needle with reverse cutting triangular point of 48 mm penetrates firm and dense tissues (skin, fascia, aponeurosis) with controlled trauma, minimising damage at the entry point. The product is sterilised by ethylene oxide and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics of reference AM113HS4801
| Reference (SKU) | AM113HS4801 (113HS4801) |
| Material | 100 % synthetic absorbable polyglycolic acid (PGA) |
| Thread structure | Braided multifilament with grooved finish |
| Coating | Polycaprolactone and calcium stearate |
| Gauge | USP 1 (metric 4) |
| Thread colour | Violet grooved |
| Thread length | 90 cm |
| Needle shape | ½ circle |
| Tip type | Reverse cutting triangular (body and point) |
| Needle size | 48 mm (HS 48) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 60-90 days |
| Sterilisation | Ethylene oxide (EO); single-use, non-reesterilizable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and general surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 40 % |
| Complete absorption | 60-90 days (by hydrolysis) |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
Polyglycolic acid (PGA) is the most widely used medium-duration braided multifilament absorbable on the market. This reference shares the absorption profile (60-90 days), strength retention, coated braided structure, USP 1 gauge, HS 48 mm ½ circle reverse cutting needle and 90 cm length with the main homologous families of medium-absorption braided absorbable suture:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (Johnson & Johnson) | VICRYL Plus (braided polyglactin 910, violet, 90 cm, ½ circle reverse cutting needle 48 mm, USP 1) | VCP1058H | Comparable by category (not interchangeable 1:1) | Copolymer composition 90/10 glycolide/L-lactide versus PGA homopolymer; declared absorption 56-70 days; same HS 48 mm reverse cutting needle, USP 1 gauge, violet and 90 cm. Code verified in catalogues of authorised distributors; consult the manufacturer’s technical data sheet before substituting. |
Other commercial houses with homologous families of medium-absorption braided absorbable suture —B. Braun with its Safil line of polyglactin 910, Medtronic with the Polysorb range and SMI with Surgicryl PGA— offer products of the same clinical category, but no confirmed reference code is available for this exact configuration (USP 1 / HS 48 mm / 90 cm). There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering.
5. Selection tips and variants of interest
USP 1 gauge (metric 4) is indicated for tissues requiring high initial strength: aponeurosis, fascia, muscle planes and moderate-to-high tension closures. The reverse cutting triangular point (HS) is recommended for penetrating firm and dense tissues without tearing (skin, fascia, aponeurosis); if the tissue is soft or friable, consider the conical point (HR).
| Reference | Variant of interest |
| AM113HS4801 | PGA USP 1, HS 48 mm triangular needle, violet, 90 cm (current product) |
| AMP113HS4801 | PGA Prime USP 1, same HS 48 mm needle, violet, 90 cm (Prime quality) |
| AM113HS4810 | PGA USP 0, same HS 48 mm needle, violet, 90 cm (smaller gauge) |
| AM113HS4802 | PGA USP 2, same HS 48 mm needle, violet, 90 cm (higher strength) |
| AM113HS4001 | PGA USP 1, HS 40 mm triangular needle, violet, 90 cm (shorter needle) |
| AM113HR4801 | PGA USP 1, cylindrical needle with HR 48 mm conical point, violet, 90 cm (soft tissues) |
| 1L13HS4801 | PGLA polyglactin 910 USP 1, HS 48 mm triangular needle, violet, 90 cm (alternative polymer) |
| AM413HS4801 | PDO monofilament USP 1, HS 48 mm triangular needle, violet, 90 cm (absorption 180-210 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions and volume orders, contact our technical-commercial team.