We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Suture (Polyglycolic Acid) | Needle ½ Circle Triangular Point Reverse Cutting HS26 (26 mm) | USP Size 1 (Metric 4) | Violet Ribbed Thread 75 cm | Ref. 112HS2601 – Box of 12 units

Original price was: 34,90 €.Current price is: 27,40 €.

Multifilament absorbable suture of 100 % polyglycolic acid (PGA) with a ½ circle reverse cutting triangular point needle (reverse cutting) of 26 mm (HS26) and gauge USP 1 (metric 4). Ribbed violet braided thread of 75 cm, coated with polycaprolactone and calcium stearate; predictable absorption by hydrolysis in 60-90 days and tensile strength retention of 75 % at 2 weeks, 50 % at 3 weeks and 40 % at 4 weeks. Sterile by ethylene oxide, single-use and minimal tissue reaction, indicated for approximation of firm tissues, ligatures and general surgery. Factory reference 112HS2601 (SKU AM112HS2601), presentation in a box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM112HS2601

Description

1. Commercial Introduction

The Absorbable Multifilament PGA Suture, reference 112HS2601 (SKU AM112HS2601), is the trusted choice for the professional seeking a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security in the approximation of firm tissues, ligatures and general surgery. Its ½ circle needle with a 26 mm reverse cutting triangular point (HS26) ensures firm, controlled penetration in non-compliant tissues, while the 75 cm ribbed violet braided thread offers optimal visibility on the surgical field and a smooth glide during suturing.

It is a synthetic, absorbable, sterile, single-use medical device with excellent value for money for the B2B supply of operating theatres, clinics, purchasing centres and surgical material distributors. Commercial presentation in a box of 12 units, with special conditions for professional buyers and a minimum order of 30 boxes.

2. Technical Explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a multifilament braided structure with a ribbed finish and a coating of polycaprolactone and calcium stearate. This configuration smooths the thread surface, facilitates passage through tissue, reduces the sawing effect and ensures excellent knot security, even in medium-to-high working gauges such as USP 1.

Absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the polymer degrades into glycolic acid, a substance metabolised by the body without causing significant tissue reaction. This profile maintains the necessary tensile strength during the first weeks of healing (75 % at 2 weeks, 50 % at 3 weeks and 40 % at 4 weeks), while the tissue regains its own strength.

The ½ circle (approx. 180°) 26 mm needle, with a reverse cutting triangular body and point, penetrates firm, fibrous and non-compliant tissues (skin, fascia, aponeurosis) with controlled trauma and without tearing, making it especially suitable for skin closures, ligatures and surgical fields with limited access. The violet colour improves thread visibility on the surgical field. The product is supplied sterile by ethylene oxide, is single-use and does not allow re-sterilisation.

3. Technical Specifications

3.1. Technical data sheet for reference 112HS2601 (SKU AM112HS2601)

Parameter Specification
Brand / Range PREMISUT (standard quality)
Factory reference 112HS2601 · SKU Cahnos AM112HS2601
Material 100 % synthetic absorbable polyglycolic acid (PGA)
Thread structure Braided multifilament with grooved finish
Coating Polycaprolactone and calcium stearate
Gauge USP 1 (metric 4)
Approximate diameter 0.40 – 0.499 mm (indicative according to USP/EP Pharmacopoeia)
Thread colour Fluted violet (colourless version available in the range)
Thread length 75 cm
Needle shape ½ circle (approx. 180°)
Tip type Triangular reverse cutting (reverse cutting), triangular body and point
Needle size HS 26 (26 mm), 1 needle per suture
Absorption mechanism Hydrolysis, between 60 and 90 days
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Regulatory standard Conforms to USP / European Pharmacopoeia gauges; CE marking (MDR)
Indications Tissue approximation, ligatures and general surgery
Presentation Box of 12 units (individual sterile sachets)
Minimum order 30 boxes

3.2. Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75% of initial strength
3 weeks 50% of initial strength
4 weeks 40% of initial strength
Complete absorption 60 – 90 days (hydrolysis)

Complete absorption by hydrolysis within 60 to 90 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a fully predictable and controlled absorption rate. Price per box of 12 units.

3.3. Size equivalence

USP size Metric size Approximate diameter
1 (this product) 4 0.40 – 0.499 mm (indicative according to Pharmacopoeia)
0 3.5 0.35 – 0.399 mm
2/0 3 0.30 – 0.349 mm

4. Equivalences and Cross-References

Polyglycolic acid (PGA) is the most widely used medium-duration braided multifilament absorbable in the surgical market and shares the absorption profile (60-90 days), tensile strength retention, coated braided structure (polycaprolactone and calcium stearate) and clinical behaviour with the homologous families of the main manufacturers: Surgicryl® PGA (SMI, Belgium), Safil® (B. Braun), DemeSORB® (DemeTECH), Assucryl® (Assut Sutures), as well as the PGA lines of Resorba® and Atramat® (Internacional Farmacéutica).

There is no equivalence table validated by the manufacturer for this specific configuration (PGA multifilament, ½ circle HS 26 mm needle, reverse cutting triangular point, USP 1 gauge, 75 cm violet thread); consult the technical department before use in tenders. Before replacing this reference in a specification, check one by one: material, USP gauge, needle size (26 mm), ½ circle curvature, point family (reverse cutting), thread length (75 cm) and colour.

The copolymer ranges of polyglactin 910 (PGLA), such as Vicryl® (Ethicon), Safil® 910 / Novosyn® (B. Braun) and Polysorb® (Medtronic), are chemically and clinically comparable by category (medium-duration braided absorbables) but not interchangeable 1:1 with homopolymer PGA: they have a shorter absorption profile (56-72 days) and a different degradation chemistry, therefore they require validation from the pharmacy service or the technical department before a formal substitution.

5. Selection tips and variants of interest

USP 1 gauge (metric 4) is indicated for tissues with moderate-to-high tension: fascia, aponeurosis, abdominal wall and ligatures of medium-calibre vessels. The HS 26 mm reverse cutting triangular point needle penetrates firm tissues without tearing (skin, fascia, aponeurosis), and the violet thread provides maximum visibility on the surgical field; if you prefer maximum aesthetic discretion, request the colourless version of the range. Consult the variants in the Cahnos catalogue to adjust gauge, geometry, colour and length for each procedure:

Reference Variant of interest
AM112HS2601 PGA standard quality, ½ circle needle HS26, USP 1, violet, 75 cm (current product)
AMP112HS2601 PGA Prime, same HS26 configuration, USP 1, violet, 75 cm (direct equivalent in higher range)
AMP112HS2610 PGA Prime, same HS26 needle, USP 0, violet, 75 cm (medium gauge)
AMP112HS2620 PGA Prime, same HS26 needle, USP 2/0, violet, 75 cm (fine gauge)
AMP112HS2630 PGA Prime, same HS26 needle, USP 3/0, violet, 75 cm (finest gauge)
AMP112HS3620 PGA Prime, needle HS36, USP 2/0, violet, 75 cm (longer needle)
P1L28HS2601 Polyglactin 910 (PGLA) Prime, HS26, USP 1, colourless, 70 cm (absorption profile of 56-72 days)

All references are supplied in a box of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare centre. As it is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours on request, contact our technical-commercial team at Cahnos.

Additional information

Product line

PREMISUT – standard quality

Manufacturer reference

112HS2601

Material

100 % absorbable polyglycolic acid (PGA)

Thread structure

Braided multifilament with grooved finish

Coating

Polycaprolactone and calcium stearate

Gauge

USP 1 (metric 4)

Thread diameter

0.40 – 0.499 mm (indicative according to Pharmacopoeia)

Thread colour

Violet grooved

Needle shape

½ circle (approx. 180°)

Tip type

Triangular reverse cutting (reverse cutting), triangular body and point

Needle size

HS 26 (26 mm), 1 needle per suture

Absorption mechanism

By hydrolysis, between 60 and 90 days

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Use

Single-use, not re-sterilisable

Indications

Tissue approximation, ligatures and general surgery

Presentation

Box of 12 units (individual sterile sachets)

Minimum order

30 boxes

Regulatory standard

Conforms to USP / European Pharmacopoeia gauges; CE marking (MDR)

Medida de aguja

HS 26

Usp

1

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Normal

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Suture (Polyglycolic Acid) | Needle ½ Circle Triangular Point Reverse Cutting HS26 (26 mm) | USP Size 1 (Metric 4) | Violet Ribbed Thread 75 cm | Ref. 112HS2601 – Box of 12 units”

Your email address will not be published. Required fields are marked *