We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGA Prime Suture | ½ Circle Triangular Reverse Cutting Needle HS 22 mm | USP 2/0 | Colourless Thread 75 cm | Box of 12 units | Ref. AMP122HS2220

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament polyglycolic acid (PGA) suture from the Prime range, mounted with a 22 mm (HS 22) ½ circle reverse cutting triangular point needle, USP size 2/0 (metric 3) and 75 cm of colourless fluted thread. Predictable absorption by hydrolysis in 60-90 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 40% at 4. Sterilised by ethylene oxide, single-use and with minimal tissue reaction; excellent knot security and smooth handling for tissue approximation, ligatures and general surgery. Reference AMP122HS2220 — presentation in a box of 12 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP122HS2220

Description

1. Product Presentation

At Cahnos we offer the absorbable multifilament polyglycolic acid (PGA) suture from the Prime range, reference AMP122HS2220, an advanced solution for tissue approximation and surgical ligatures. It combines a ½ circle needle with a 22 mm reverse cutting triangular point, USP 2/0 gauge and 75 cm colourless fluted thread: maximum penetration performance with the maximum aesthetic discretion of the colourless thread. Designed for the professional who demands reliable, manageable and predictable behaviour in the operating theatre, it is the reference choice for hospitals, clinics, purchasing centres and distributors of surgical supplies, with excellent value for money.

2. Technical explanation

Polyglycolic acid (PGA) is a synthetic absorbable polymer presented in a braided multifilament structure with a fluted finish and a coating of polycaprolactone and calcium stearate. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 2/0. Absorption occurs by hydrolysis, i.e., degradation of the polymer in contact with organic fluids, over a predictable period of 60 to 90 days and independent of the patient’s enzymatic activity. This profile makes the suture suitable for tissues that require wound support during the first weeks of healing. The ½ circle needle with a 22 mm reverse cutting triangular point (inverted triangular) penetrates firm and fibrous tissues with controlled trauma, avoiding tearing; it is especially useful in skin, fascia, aponeurosis and mucous membranes. The colourless thread offers maximum aesthetic discretion in visible areas or superficial suturing. The product is supplied sterile by ethylene oxide, is single-use and does not allow re-sterilisation.

3. Technical Specifications

3.1. Technical data sheet for reference AMP122HS2220

Brand / Range PGA Prime (premium quality)
Reference (SKU) AMP122HS2220
Material 100% synthetic absorbable polyglycolic acid (PGA)
Thread structure Multifilament braided fluted
Coating Polycaprolactone and calcium stearate
Gauge USP 2/0 (metric 3)
Thread colour Colourless
Thread length 75 cm
Needle shape ½ circle (1/2 circle)
Tip type Triangular with reverse cutting (inverted triangular / reverse cutting)
Needle size HS 22 (22 mm)
Absorption mechanism By hydrolysis, between 60 and 90 days
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Approximation of soft tissues, ligatures and general surgery
Presentation Box of 12 units

3.2. Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 40 %
Complete absorption 60 – 90 days by hydrolysis

Complete absorption by hydrolysis between 60 and 90 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate.

3.3. Size equivalence

USP size Metric size Approximate diameter
2/0 3 0.30 – 0.349 mm (indicative according to Pharmacopoeia)

4. Equivalences and Cross-References

Braided and coated polyglycolic acid (PGA) is one of the most widely used medium-term absorbable multifilament sutures in the surgical market, and the ½ circle configuration with a 22 mm reverse cutting triangular point is one of the most common for firm tissue approximation. However, for the exact configuration of this data sheet (HS 22 needle, 22 mm, ½ circle, reverse cutting, USP 2/0, colourless thread, 75 cm) there is no equivalence table validated by the manufacturer; consult with the technical department before use in a tender. At category level, the homologous families to compare are: SMI (Belgium) Surgicryl PGA, which in its official catalogue includes the HS 22 / 2/0 / 75 cm option with the same polymer (braided PGA coated with polycaprolactone and calcium stearate) in violet and colourless versions — exact code for the colourless variant pending confirmation from the manufacturer or its distributor —; B. Braun Safil (braided PGA, reverse cutting needles); and the polyglactin 910 lines (Ethicon’s Vicryl, Medtronic’s Polysorb, Assut’s Surgicryl 910 / Assucryl 910), which share indication and medium absorption profile but use a different polymer from 100 % PGA, so they are not interchangeable 1:1. Before any substitution in a tender specification, check the manufacturer’s technical data sheet: needle length and shape (½ circle), point family (reverse cutting), size (22 mm), USP gauge, colour and thread length. There is no equivalence table validated by the manufacturer for this combination; consult with the technical department before use in a tender.

5. Selection tips and variants of interest

The USP 2/0 gauge (metric 3) offers an ideal balance between initial strength and handling for fine tissues, ligatures and general surgery. The ½ circle needle with reverse cutting triangular point is the recommended choice for penetrating firm and fibrous tissues without tearing (skin, fascia, aponeurosis, mucous membranes), while for friable or delicate tissues a conical point (HR/FR) is preferred. The colourless thread provides maximum aesthetic discretion; if maximum visibility over the surgical field is required, request the violet version of the family. For longer support times (180-210 days), consider the polydioxanone (PDO) family, and if a slightly faster absorption profile is desired (56-72 days), polyglactin 910 (PGLA).

Reference Variant of interest
AM118HS2220 PGA standard quality USP 2/0, same HS 22 needle, violet thread 70 cm (SKU AM118HS2220)
AMP112HR3020 PGA Prime USP 2/0, HR 30 conical needle, violet, 75 cm (SKU AMP112HR3020)
AMP118FR4020 PGA Prime USP 2/0, FR 40 taperpoint conical needle, violet, 70 cm (SKU AMP118FR4020)
AM112HR4820 PGA USP 2/0, HR 48 conical needle, violet, 75 cm (SKU AM112HR4820)
AMP113HRT4020 PGA Prime USP 2/0, HRT 40 trocar point needle, violet, 90 cm (SKU AMP113HRT4020)

All references are supplied in a box of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure and store in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours made to order, contact our technical-commercial team at Cahnos.

Additional information

Brand / Range

PGA Prime

Reference

AMP122HS2220

Material

100% synthetic absorbable polyglycolic acid (PGA)

Thread structure

Multifilament braided fluted

Coating

Polycaprolactone and calcium stearate

Gauge

USP 2/0 (metric 3)

Tip type

Reverse cutting triangular (inverted triangular)

Needle size

HS 22 (22 mm)

Strength retention

75 % (2 weeks), 50 % (3 weeks), 40 % (4 weeks)

Sterilisation

Ethylene oxide, single-use, non-resterilizable

Presentation

Box of 12 units

Indications

Approximation of soft tissues, ligatures and general surgery

Medida de aguja

HS 22

Usp

2/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGA Prime Suture | ½ Circle Triangular Reverse Cutting Needle HS 22 mm | USP 2/0 | Colourless Thread 75 cm | Box of 12 units | Ref. AMP122HS2220”

Your email address will not be published. Required fields are marked *