Description
1. Commercial Introduction
The absorbable monofilament polydioxanone (PDO/PDS) suture from the Prime line is the reference choice when the operating theatre needs a thread with prolonged support, predictable behaviour and maximum security in knot tying. This presentation combines a violet 70 cm thread in gauge USP 2/0 with a straight 60 mm needle with triangular point in conventional cutting (GS60), a configuration designed for firm and controlled penetration in tissues that require a direct passage without curvature, very common in open surgery on accessible planes.
Available in a box of 12 sterile units, with a minimum order of 30 boxes, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality homogeneity and complete traceability in each package.
2. Technical Explanation
Polydioxanone is a synthetic absorbable polymer —poly(p-dioxanone)— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity. This ensures a highly reproducible absorption kinetics between individuals and minimal tissue response, with complete absorption within 180 to 210 days, one of the longest support windows among absorbable sutures.
Being a non-grooved monofilament, the thread has no wicking effect or interstitial spaces: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory reaction compared to braided threads. The straight needle with conventional cutting triangular point has three cutting edges that penetrate firm and fibrous tissues in a straight path, without the need to rotate the wrist, ideal for superficial planes, fascia and structures accessible in direct field. The violet colour improves thread visibility on the surgical field. Sterile single-use product, not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference AMP418GS6020
| Parameter | Specification |
| Manufacturer reference | P418GS6020 |
| SKU | AMP418GS6020 (Prime line) |
| Material | Polydioxanone (PDO/PDS), synthetic monofilament of poly(p-dioxanone), non-grooved |
| Thread structure | Monofilament, non-braided |
| USP size | USP 2/0 |
| Thread length | 70 cm |
| Thread colour | Violet (high visibility) |
| Needle shape | Straight |
| Needle tip | Triangular, conventional cutting |
| Needle size | GS60 – 60 mm, one needle per suture |
| Absorption mechanism | Hydrolysis (180-210 days) |
| Sterilisation | Ethylene oxide (EO), single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75% of initial strength |
| 4 weeks | 60-70% of initial strength |
| 8 weeks | 45% of initial strength |
| Complete absorption | 180-210 days by hydrolysis |
This prolonged force retention profile maintains the necessary support during the critical healing phase of slow-healing tissues, which is why it is recommended for closures of fascia, aponeurosis and structures subjected to sustained traction, as well as in paediatric cardiovascular surgery where tissue growth is expected.
4. Equivalences and Cross-References
Monofilament polydioxanone is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). On the verified configuration of this data sheet (straight needle with conventional cutting triangular point of 60 mm, gauge USP 2/0, violet 70 cm thread), no reference from another manufacturer has been found in primary sources that matches field by field in all required parameters (material, gauge, attachment, curvature, point family and needle size), therefore there is no manufacturer-validated equivalence table; consult the technical department before use in tenders.
As homologous market families to be verified code by code before any substitution: the PDS II® and PDS Plus® from Ethicon line (violet monofilament polydioxanone), the MonoPlus® from B. Braun/Aesculap line (monofilament polydioxanone), the Surgicryl® PDO from SMI line and Maxon from Medtronic (polyglyconate). It should be noted that, in Ethicon’s official catalogue, the straight conventional cutting needle of the PDS II family (model KS, 60 mm, 70 cm) is only marketed in undyed colour and in USP gauges 3/0 and 4/0 (refs. Z663H and Z662H), so it is not interchangeable 1:1 with this violet reference in 2/0. All alternatives must be checked in their official technical data sheet: USP gauge, thread length, colour, curvature, body, point and needle size. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always check the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin and subcutaneous tissue, 3/0 and 2/0 for general soft tissue and moderate tension planes, and USP 1 and above for fascia, aponeurosis and structures under high tension. The needle shape is also decisive: the straight needle is handled directly with the hand or a straight needle holder and is especially practical in superficial planes and accessible fields; the conventional cutting triangular point is indicated for firm and fibrous tissues, while the conical point is reserved for delicate and well-perfused tissues (vessels, parenchyma) and the trocar point for intermediate tissues.
In the Cahnos catalogue you will find the PDO/PDS family in other gauges, needle sizes and presentations (GS60 straight needle in 3/0 and 4/0, ½ circle needles with conical point and trocar point, double needle and loop format), always in a box of 12 units. As it is sterile single-use material, check the integrity of the package before each procedure, respect the expiry date and keep the reference and batch for traceability in the operating theatre. Store in a cool, dry place, below 30 °C and protected from sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews